8. Connection and initial operation of the accessories
8.4 Travel limit signals (relay)
Function:
On reaching the OPEN / CLOSE travel limits, the corresponding relay connects.
and signal light connection
Function:
The signal lights flash during power operation of the door. When the automatic
timer is activated, the signal lights are flashing additionnaly during warning time.
Connection of retrofit kit OPEN / CLOSE light (Art.No. 152 137)
• Connect both sockets X10 of control unit and retrofit kit with a system cable,
as shown in fig. 12.
• Connect the control elements, e.g. membrane keypad Command 612,
to socket X10A of the retrofit kit.
Fig. 12: Trave limit signal and signal light
Legend:
H1 Signal light CLOSE
H2 Signal light OPEN
H41 Signal light DRIVE IN (orange)
H43 Signal light DRIVE OUT (orange)
K1 Relay CLOSE
K2 Relay OPEN
K3 Relay SIGNAL LIGHTS
Plug connections:
X8A Travel limit relay
X8B Signal light relay
X10 Control unit
X10A External control elements
- - - - - site cabling