Function:
By means of membrane keypad Command 612 (Art.-No. 153 810) the door can
be travelled to direction OPEN or CLOSE and it can be stopped. The integrated
key switch makes it possible to switch off the control unit.
5.1 Connection of membrane keypad 'Command 612'
5. Initial operation of control unit C 14 / C 15
Fig. 4: Connection of membrane keypad
Connection:
• Unscrew all four screws in upper
part of housing.
• Fix the bottom part of housing to
the wall at a well reachable place
near door.
• Insert the enclosed system cable
between bottom part of housing
and wall.
• Remove the short circuit plugs from
socket X10 of control unit (A1).
• Connect membrane keypad (A2) and
control unit acc. to fig. 4.
• Close housing of membrane keypad.
• Set key switch to ON position
(blue mark).