10.A Programming of Special photocell
S20
ON without Special photocell
OFF with Special photocell
B Programming of Control 200, Control 300
S19
ON Control 200 or Control 300 not installed
OFF Connection of Control 200 or Control 300 (figs. 25 & 26)
C Plug socket X4 electronic aerial or diagnostic device
11.Plug socket X2b for optosensor, cable slack device and wicket door contact
12.Optosensor circuit board
A X7c Plug-in connecting terminal for optosensor coiled cable
B Green LED H1a control voltage
C Yellow LED H6 static current circuit closed
(does not light up on actuation of cable slack device or wicket door contact)
D X7d plug socket for 1st cable slack device
E X7e plug socket for receiver optosensor
F X7f plug socket for connecting cable to distributor housing
G X7g plug socket for wicket door contact
H Red LED H5 optosensor function indicator (only lights up when door closing)
For adjustment purposes, terminal 18 of the optosensor can be switched to continuous operation by
disconnecting the cable X7c. (If functioning correctly, LED H5 glows constantly)
I Dual switch for setting/adjusting the sensitivity
ON MAX
OFF
ON
OFF
ON
OFF
ON
OFF MIN
J X7h terminal block static current circuit (if installed)
13.Connecting circuit board optosensor coiled cable
A X7a plug socket to control unit
B X7b Plug socket for coiled cable to optosensor circuit board
14.Distributor optosensor and 2. cable slack device
A Plug connection to optosensor circuit board
B Plug connecton for cable slack device with short circuit plug (this is removed, if cable slack device is installed)
C Plug connection to transmitter optosensor
15.Connecting example „IMPULSE or PULL SWITCH“ button
16.Connecting example „IMPULSE“ key switch
17.Connecting example „OPEN“ and „CLOSE“ key switches
18.Connecting example „STOP“ and „IMPULSE“ buttons
19.Connecting example „OPEN“, „STOP“ and „CLOSE“ buttons
20. Connecting example „OPEN, STOP, CLOSE lockable“ buttons
21.Connections for potential-free limit switch contacts requiring
supplementary relay circuit board, flat cable item no.: 562 332
K6a Contact between 80 and 81 closed or contact between 80 and 82 opened, when door not closed.
K7a Contact between 84 and 85 closed or contact between 84 and 86 opened, when door at its OPEN
end of travel position.
X2f Plug connection „Control 100 control unit“
X6 Connecting terminal block „relay circuit board“
X6a, X6b Plug connections „relay circuit board“
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Marantec Control 116 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Marantec Control 116 in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish, Spanish, Norwegian as an attachment in your email.

The manual is 7,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info