22.Connections for photocell as safety device.
Special 603 photocell: item no. 564 576
When the light path is interrupted, contact 1-3 is opened.
Programming switch S20 at OFF.
KL Photocell
23.Connections for Control 112, door half open and wicket door contact *
S12 Limit switch „HALF OPEN“
S15 Change-over switch“OPEN/HALF OPEN“
X15 Supplementary terminal block „HALF OPEN“, in „Control 112“ control unit housing
24.Control 400
Wiring of Control 110 control unit with Control 400 induction loop detector, item no.: 564 022
„OPEN“ impulse given by induction loop
X9 Terminal block „Control 400 induction loop detector“
25.Control 200
Wiring of Control 110 control unit with Control 200 automatic timed return (item no.: 564 007), Control 400
induction loop detector, pull switch and photocell Special. „OPEN“ impulse given by induction loop and pull switch.
„CLOSE“ by Control 200 automatic timed return.
Programming switch S19 in Control 110 control unit at „OFF“
Control 210 Automatic week timer ON/OFF (if installed)
F1b Fuse 4 A max.
H41,H42 Traffic lights (entry/exit)
K41 „Flashing“ relay
K43 „STOP“ relay
K44 „IMPULSE“ relay
S32 Automatic ON/OFF (if installed)
S33 „IMPULSE“ button with automatic timed return
X8,X8b Connecting terminal block „Control 200“
X8a Plug connection „Control 200“
X9 Terminal block „Control 400 induction loop detector“
a Before connecting photocell, remove bridge a
26.Control 300
Wiring for Control 110 control unit with Control 300 traffic light controls, Control 300 induction loop detector, pull
switch and photocell KL. Impulse given via induction loop and pull switch.
Traffic regulated via Control 300 traffic light control system, item no.: 564 020
Programming switch S19 in Control 110 control unit at „OFF“.
F1b Fuse 4 A max
H40a LED limit switch „open“
H40b LED limit switch „not closed“
H41 Traffic light „exit red“
H42 Traffic light „exit green“
H43 Traffic light „entry red“
H44 Traffic light „entry green“
K41 Traffic light relay
K42a Traffic light „exit“ relay
K42b Traffic light „entry“ relay
K43 „Stop“ relay
K44 „Impulse“ relay
S30 Button „impulse exit“
S31 Button „impulse entry“
S32 Automatic „ON/OFF“
WZ Week timer (if installed)
X8,X8b „Control 300“ terminal block
X8a „Control 300“ plug connection
X9 Terminal block „Control 400 induction loop detector“
Optosensor check
Remove the transmitter or receiver from the door bottom edge seal. Open and close the door.
The next door closing cycle must take place without self-hold.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Marantec Control 110 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Marantec Control 110 in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish, Spanish, Norwegian as an attachment in your email.

The manual is 7,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info