8 Operating instructions, Comfort 860, 861 (#119162 – EN)
3. Installation
3.1 Safety instructions for installation
WARNING!
Danger due to a failure to observe the installation instructions!
This chapter contains important information for the safe
assembly of the product.
Read this chapter through carefully before assembly.
Follow the safety instructions.
Perform the assembly as described.
Assemblybyqualiedspecialistpersonnelonly.
“1.2.2 Specialist personnel”
Electricalworkmustbeperformedbyqualiedelectricians
exclusively.
“1.2.2 Specialist personnel”
Before assembly, it is necessary to make sure that the power
supply has been and remains disconnected. Only establish the
power supply when prompted to do so in the corresponding
assembly step.
It is essential to adhere to the local protection regulations.
It is essential that mains supply cables and control cables are
laid separately. The controls voltage is 24 v DC.
The gate must be in good mechanical condition:
The gate comes to a stop in any position.
The gate is easy to move.
The gate opens and closes correctly.
All pulse transmitters and control devices (e. g. remote control
buttons) must be installed within sight of the gate and at a
safe distance from the moving parts of the gate. A minimum
installation height of 1.5 metres must be observed.
Onlyusexingmaterialthatissuitablefortherespective
construction substrate.
3.2 Preparing for installation
Before commencing installation, the following works must be
carried out without fail.
Supply package
Check that all the parts are present.
Check that all the necessary accessory parts for your
installation situation are present.
Installation site
The installation site must meet the following conditions:
Theremustbesucientspacetoallowthemotorunitandthe
toothed rack to be installed on the inside of the gate with the
gate closed.
The motor unit must not extend into the gateway area.
For cantilevered gates, the motor unit must be mounted at the
mid point between the carrier roller assemblies.
“2.5 / 2”
The foundations must be suitable for heavy-duty wall plugs.
Check whether the existing foundations are suitable.
Check the routing of the supply cable.
Pay particular attention to the cable exit point where the motor
unit is to be installed.
“3.2 / 2”
Gate system
Remove any components from the gate (such as ropes, chains,
brackets, etc.) that are no longer needed.
All equipment that will no longer be required after the gate
operator system has been installed must be taken out of
service.
Ensure that a suitable mains connection and a mains isolator
switch are available for your gate system.
The minimum cross-section of the earth cable must be
3x1.5mm2.
Ensure that all cables are suitable for outdoor use with respect
to UV resistance and cold resistance.
Checkthatthegatetobeoperatedfullsthefollowing
conditions:
When closed, the gate should extend at least 400 mm
further than the clear width on the installation side.
The gate must have a mechanical gate stop in both
directions.
Theclosingedgesmustbettedwithaexiblegateseal.
“2.3 Protection of closing edges”
Only install the motor unit with the gate in the closed position.
NOTICE
Material damage resulting from incorrect installation of the
gate operator!
The following conditions must be met to prevent the gate and
operator systems from being damaged:
The gate itself must be straight and torsion-free, so that the
distance between the motor unit and the gate never changes.
The motor must be aligned to face the gate, so that the spur
gear can mesh with the toothed rack whatever the position of
the gate.
Thewallplugsfortheoorconsolemustbeatleast80mm
from the edge of the foundations to prevent the foundations
from breaking out.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Marantec Comfort 861 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Marantec Comfort 861 in the language / languages: English as an attachment in your email.

The manual is 2,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Marantec Comfort 861

Marantec Comfort 861 User Manual - German - 20 pages

Marantec Comfort 861 User Manual - Dutch - 20 pages

Marantec Comfort 861 User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info