GB
I. Control connections
F1 Fuse 1A max
F2 Fuse 10A max
H4 LED reference point
H20 Light on building, flashing light,
revolving beacon (250 V, 60 W max.)
K1 Main current safety relay 'open' for
door 1
K2 Main current safety relay 'close' for
door 1
K3 Main current safety relay 'open' for
door 2
K4 Main current safety relay 'close' for
door 2
K5 Main current safety relay for
magnetic lock
K6 Main current safety relay for light
K11 Magnet lock, door 1*
K12 Magnet lock, door 2*
KE External receiver (if available) at
impulse operation bridge a
KL Photocell driveway
M1 Motor 24V DC, door 1
M2 Motor 24V DC, door 2 (only for
double-wing version)
S Mains insulator switch or button
'emergency cut-out'*
S0 'Stop' button *
S1
'Impulse' button for door 1 and door 2*
S2
'Open' button for door 1 and door 2*
S4
'Close' button for door 1 and door 2*
S5 'Impulse' button for door 1
S18 Programming switch 2, stop button
S20 Programming switch photocell KL
S21a RPM sensor for motor 1
S21b RPM sensor for motor 2
S22a Reference point sensor for door 1
S22b Reference point sensor for door 2
S23 Switch for singe-wing and double-
wing versions
T1 Transformer
X2a Mains connection socket
X2b Socket for building lighting
X2c Motor connection socket for door 1
X2d Motor connection socket for door 2
X2e Connection socket for
'OPEN - STOP - CLOSE' button
X2f Impulse button connection socket for
door 1
X2g Photocell connection socket
X4 'Electronic aerial' socket
X5 Connection socket for
'OPEN - STOP - CLOSE' button
X6 Relay potential-free limit switch
information
* if available
Factory-fitted bridged clamps, programming buttons:
Description Terminal block Bridged clamps Programming buttons
'Stop' button X2e 12 - 13 -
'Stop' button X5 - S18
Photocell
driveway KL - S20
'Impulse' button X2e a -
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Marantec Comfort 520 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Marantec Comfort 520 in the language / languages: English as an attachment in your email.

The manual is 1,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Marantec Comfort 520

Marantec Comfort 520 User Manual - German - 76 pages

Marantec Comfort 520 User Manual - German - 76 pages

Marantec Comfort 520 User Manual - French - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info