English Page 54
G. Display functions and programming possibilities
2. Programming 'soft stop CLOSE'
LED 2 flashes.
• With button or the function
'soft stop CLOSE' can be set in steps
from 1 (without) to 4 (500 mm)
(according to table).
• Save your setting with programming
button .
The control unit changes automatically to
programming menu 'intermediate position'.
English Page 39
G. Display functions and programming possibilities
GB
LED's 4 and 6 are flashing.
• With button or the 'automatic
cut-out' can be set in steps from 1 (most
sensitive value) to 16 (according to table).
• Save your setting with programming
button .
The control unit changes automatically to
programming 'offset learned power limit'.
Advice!
When re-programming the end positions (1st programming
level) the pull force is learned once more.
With new setting of the end positions the force values are
determined automatically. Depending on the door travel
properties increasing of the force values may be necessary.