English Page 38
G. Display functions and programming possibilities
3. Programming 'automatic cut-out CLOSE'
Attention!
The automatic cut-out is set automatically.
Only change it if necessary (error No. 10)
When increasing the set value the max. force in CLOSE
direction is increased and thus the sensitivity of the automa-
tic cut-out is reduced.
Attention!
Always test the max. allowed operating forces according to
EN 12445 and EN 12453!
Advice:
The setting of the automatic cut-out corresponds to the
maximum power of the operator. At the first travel to
OPEN or CLOSE direction after 'POWER ON' the automatic
cut-out is effective according to the adjustment. For further travels the
self-learned power, that is more sensitive, is effective. The automatic
cut-out is still the upper limit of power.
GB
English Page 55
G. Display functions and programming possibilities
3. Programming 'intermediate position'
LED 3 flashes.
• Travel the door to the desired position
with button or .
• Save this position with programming
button .
The control unit changes automatically to
the programming menu 'remote control
intermediate position'.