English Page 58
G. Display functions and programming possibilities
Adjustable values of the 4th programming level
Legend:
LED off
LED on
LED flashes slowly
LED flashes quickly
Menu 1: Excess travel stop
Menu 4: Remote control intermediate position
Menu 3: Intermediate position
Menu 2: Soft stop CLOSE
BUTTON P
BUTTON
1234567
30 40 50 55 65 80 100
sec. sec. sec. sec. sec. sec. sec.
without 200mm 300mm 500mm
Travel the door to the desired position with button
or
LED 7 flashes slowly –> button on hand transmitter actuated,
LED 7 flashes quickly
English Page 35
GB
G. Display functions and programming possibilities
1. Programming of external photocell
Advice:
Still hold the programming button when LED 2
starts to flash after 2 sec. In order to come to the 2nd
programming level, hold programming button for
further 8 sec. (LED 2 is then flashing quickly).
• Press button for more than 10 sec,
until LED 2 flashes quickly.
• Release button .
LED 1 flashes.
• Press button to make a connection
of external photocells possible.
- LED 1 is on:
Operation with system photocell
- LED 1 is on, LED 2 is flashing:
Operation with 2-wire photocell
- LED's 1 and 2 are on:
Operation with system and 2-wire
photocell
• When pressing button the operator
can be run without external photocell:
- LED 1 is flashing.
• Save your setting with programming
button .
The control unit changes automatically
to the programming procedure 'auto-
matic cut-out OPEN'.