G. Display functions and programming possibilities
Extended operator functions - 5th programming level
27
Explanation of the 5th programming level:
The light time of the operator
light can be programmed
The signal lights can be
programmed to flashing
or permanent light
The electric push-open security
device can be programmed as
alarm
Functions
Menu 1:
- Programming light
time
Menu 2:
- Programming
signal lights
Menu 4:
- Programming
external relay
alarm function
Explanation
Factory settings
180 sec.
none
none
Advice:
External signal lights can be connected to the operator if:
- the relay retrofit kit 'door function OPEN-CLOSE+Light' is
connected to the control unit (for standard operators in
housing, Art.-No.: 152137),
- the automatic timer function is activated.
This exit can be programmed for flashing or glowing signal lights.
English Page 33
GB
G. Display functions and programming possibilities
Advice:
The values for the automatic cut-out (= max. force) and
learning power limit (= power curve) can be set manually
in the 2nd programming level.
A setting should always be carried out as soon as a less
sensitive setting has to be chosen due to door travel pro-
perties caused by site conditions, as otherwise the automa-
tic cut-out or power limit would react and cause malfunc-
tions.
In general you have to take care that the allowed opera-
ting forces according to EN 12445 and EN 12453 are not
exceeded.
Extended operator functions (2nd programming level)