D. Installation
Preparation
• Unpack the boom and the motor unit and keep it ready for mounting.
Required tools
2
1
Combination wrench SW 10
Combination wrench SW 13
Socket wrench SW 8
Socket wrench SW 10
Socket wrench SW 13
Screw driver, size 5
Screw driver, size 8
Phillips Screw driver, size 2
Masonry drill ø 6 mm
Masonry drill ø 10 mm
Metal drill ø 5 mm
Pliers
Hack saw
Electric drill
Electric drill
Attention!
Before drilling, cover the motor unit with foil or cardboard.
Drilling dust and chippings can lead to malfunctions.
Site requirements
• Please suspend the motor unit together with the boom in such a way,
that the upper door edge lies approx. 10 mm below the downward horizontal
boom edge- measured at the highest point of the opening course
(see points 8, 9 and 10).
• Mount the unit to the ceiling according to the site requirements.
Please observe as well the indicated measurements for wall plug drilling.
3
GB
English Page 85
N. Index of illustrations
Fig. D.1: Required tools
Fig. D.2: Site requirements
Fig. D.3: Push on adapter sleeve
Fig. D.4: Turn operator unit
Fig. D.5: Boom on operator
Fig. D.6: Screw boom to operator
Fig. D.7: Mount suspension clamp
Fig. D.8: Mount securing sleeve
Fig. D.9: Lintel joining plate
at the boom end piece
Fig. D.10: Release pin out of carriage
Fig. D.11: Release pin inside carriage
Fig. D.12: Release the carriage
Fig. D.13: Operator with up-and-over
door
Fig. D.14: Operator with sectional door
Fig. D.15: Operator with heavy
sectional door
Fig. D.16: Operator with retractable
up-and-over door
Fig. D.17: Fixing angle for adapter arm
Fig. D.18: Adapter arm at the door
Fig. D.19: Measurements of adapter
arm
Fig. D.20: Suspension of operator
system
Fig. D.21: Separate door from
operator - 1
Fig. D.22: Separate door from
operator - 2
Fig. D.23: Connect door with operator
Fig. E.1: Hand transmitter
Fig. E.2: Open hand transmitter /
Insert battery
Fig. E.3: Attachment clip
for hand transmitter
Fig. E.4: Learn hand transmitter coding
Fig. E.5: Change hand transmitter
coding
Fig. F.1: Electronic aerial
Fig. F.2: Summary on control unit
housing Control 53
Fig. F.3: Summary on electronic
control unit Control 53
Fig. F.4: Function of the coding
switches S19, S20 and S20A
Fig. H.1: Cabling plan
Control 53
Fig. H.2: Wiring diagram
Comfort 257
Fig. H.3: Wiring diagram
Comfort 257 closing edge
safety device
Fig. H.4: Connection control unit –
door
Fig. I.1: Travel limit signals (relay)
Fig. I.2: Signal light connection for
automatic timer function
Fig. I.3: Lighting (relay for special
functions)
Fig. Q.1: Supply package
Comfort 257 - 1
Fig. Q.2: Supply package
Comfort 257 - 2
8


Need help? Post your question in this forum.

Forumrules
1

Forum

marantec-comfort-257

Reset search

  • Hi
    in unser Gerage ist der Marantec Comfort 150 verbaut. Dieser war eine längere Zeit jetzt ausgeschaltet. Position ist auf "tor auf" aber der Motor zeigt die Postion "TOr zu" an. was kann ich machen?
    Submitted on 14-10-2022 at 15:13

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Marantec Comfort 257 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Marantec Comfort 257 in the language / languages: English as an attachment in your email.

The manual is 1,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Marantec Comfort 257

Marantec Comfort 257 User Manual - German - 46 pages

Marantec Comfort 257 User Manual - German - 46 pages

Marantec Comfort 257 User Manual - French - 46 pages

Marantec Comfort 257 Installation Guide - All languages - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info