32 Operating Instructions, Comfort 220.2, 250.2, 252.2, 250.2 speed GB (#83988)
9. Extended operator functions
Menu 5: Function of the direction command transmitter
Menu 6: Function of the impulse command transmitter
Setting Direction command transmitters Explanations
A5 not active
The direction command transmitters only give a command
when the door is stationary.
B5 STOP only
A moving door is stopped by every direction command
transmitter.
Setting Impulse command transmitters Explanations
A6 not active
The impulse command transmitters only give a command
when the door is stationary.
B6 STOP only, then standard sequence
A moving door is stopped by every impulse command
transmitter. The next command starts the drive system
running in the opposite direction
(OPEN - STOP - CLOSE - STOP - OPEN).