9. Extended operator functions
9.3 Functions overview for the levels
Caution!
Important factory default settings can be changed using the extended functions.
All the parameters must be set correctly to avoid damage to persons or property.
Attention!
After a reset, all the parameters revert to the factory settings.
In order to ensure that the controls operate properly:
- all the required functions must be re-programmed,
- the remote control unit must be re-programmed,
- the drive system must be driven once to the OPEN and CLOSED door positions.
Level 1 – Basic functions
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 3: Intermediate position OPEN
Set using the (+ / OPEN) and (- / CLOSE) buttons
“Intermediate position OPEN” – closing function is possible with automatic closing timer
Menu 4: Intermediate position CLOSE
Set using the (+ / OPEN) and (- / CLOSE) buttons
Menu 7: Relay output (only programmable with optimum signal light relay)
A7 B7 C7 D7 E7 F7 G7 H7 I7 J7 K7 – – – – –
Menu 8: RESET
A8 B8 C8 D8 E8 F8 – – – – – – – – – –
Advice:
- Only the intermediate position that was programmed last can be used.
- If an automatic closing timer is activated (Level 3 / Menu 1), the relay output (Level 1 / Menu 7) cannot
be programmed.
Reference:
If changes are made in Menus 3 and 4 in Level 1, a new performance check must be carried out