16 Operating Instructions, Comfort 220.2, 250.2, 252.2, 250.2 speed GB (#83988)
8. Initial operation
8.4 Express programming
The controls are programmed using the plus (+),
minus (-) and (P) buttons.
If no buttons are pressed within 120 seconds while in
programming mode, the controls revert to operating
mode. A corresponding message is displayed.
Reference:
The messages are explained in
Section 10.
Preconditions
The following conditions must be assured before
express programming can commence:
- the door must be in the CLOSED end position.
- the carriage must be connected up.
Advice:
When programming the OPEN and
CLOSED door positions, the reference
point must be passed.
• Carry out the express programming according to the
following procedure.
Advice:
- For proper initial operation of the
operator system, the express
programming procedure must be
carried out. This applies for initial
operation and after a reset.
- A photocell in the door frame area is
automatically programmed during
express programming. No additional
programming steps are necessary for
this purpose.
- A door frame position that has been
programmed for a photocell can only
be deleted by resetting the control.
- After altering the door frame position,
a reset must be carried out followed
by express programming.
Attention!
To ensure correct operation, the path of
the photocell beam must not be inter-
rupted during the express programming
procedure.
Exception: The door leaf in conjunction
with a photocell in the door frame
area.
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible –