G. Display functions and programming possibilities
GB GB
In case of a malfunction the control light
MALFUNCTION (D) is flashing.
• Shortly press button 쒊 .
The current error number is displayed
by irregularly flashing LED's (e.g. error 7).
Advice:
To determine the error number add the figures of the
irregularly flashing LED’s.
See as well point I 'error numbers'.
Error messages
Preparation for programming
- The operator has to be mounted ready for operation.
- The door is not yet closed completely.
- If there is a driveway photocell, it should be connected!
20
Advice:
If the photocell / photocells are correctly mounted and aligned,
the function 'photocell' is recognized automatically during
programming!
N Connection terminals for external impulse button, 2-wire system
photocell (Art.-No. 47 816)
O Socket for 'external control elements'
P Socket for 'electronic aerial', 'system photocell'