178 Part Number 80-0111-9 6/11
Fan Cycle Control
QM45/Q130/Q170/Q210/Q270
Function
Cycles the fan motor on and off to maintain proper
operating discharge pressure.
The fan cycle control closes on an increase, and
opens on a decrease in discharge pressure.
Specifications
Check Procedure
Disconnect electrical power to the ice machine at the
electrical service disconnect.
Verify fan motor windings are not open or grounded,
and fan spins freely.
Connect manifold gauges to ice machine.
Hook voltmeter in parallel across the fan cycle control,
leaving wires attached.
Reconnect electrical power to the ice machine and set
the ON/OFF/WASH toggle switch to ON.
Wait until water flows over the evaporator then refer to
chart below.
Model
Cut-In
(Close)
Cut-Out
(Open)
QM45 145 psig 5 110 psig 5
Q130 250 psig 5 200 psig 5
Q170 275 psig 5 225 psig 5
Q210 275 psig 5 225 psig 5
Q270 250 psig 5 200 psig 5
System
Pressure:
Reading
Should Be:
Fan Should
Be:
above cut-in 0 volts running
below cut-out line voltage off
178


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Manitowoc SM50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Manitowoc SM50 in the language / languages: English as an attachment in your email.

The manual is 5,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info