State of abnormality Probable cause (malfunction) Remedy
The cleaner does not run along with
the switch operation of the tool.
The wireless unit is not installed into the
cleaner and/or the tool.
The wireless unit is improperly installed
into the cleaner and/or the tool.
Install the wireless unit correctly.
The terminal of the wireless unit and/or
the slot is dirty.
Gently wipe off dust and dirt on the terminal of the
wireless unit and clean the slot of the cleaner and/
or the tool.
The wireless activation button on the
tool have not been pushed.
Push the wireless activation button on the tool
briey.Makesurethatthewirelessactivationlamp
is blinking in blue.
The stand-by switch on the cleaner is
not set to " I (ON)".
Set the stand-by switch on the cleaner to " I (ON)".
More than 10 tools are registered to
the cleaner.
Perform the tool registration again.
If more than 10 tools are registered to the cleaner,
the tool registered earliest will be cancelled
automatically.
The cleaner erased all tool
registrations.
Perform the tool registration again.
No power supply Supply the power to the tool and the cleaner.
The tool and cleaner are away from
each other (out of the transmission
range).
Get the tool and the cleaner closer to each other.
The maximum transmission distance is approxi-
mately 10 m however it may vary according to the
circumstances.
Radio disturbance by other appliances
which generate high-intensity radio
waves.
Keep the tool and the cleaner away from the appli-
ances such as Wi-Fi devices and microwave ovens.
The cleaner runs while the tool's
switch trigger is not pulled.
Other users are using the wireless acti-
vation of the cleaner with their tools.
Perform one of the following way;
- set the stand-by switch on the cleaner to "O"
position or;
- turn off the wireless activation button of the other
tools or;
- cancel the tool registration of the other tools.
Cannot erase all tool registrations in
the cleaner.
Pressing the wireless button on the tool. Press the wireless button on the cleaner for erasing
all tool registrations.
The stand-by switch on the cleaner is
not set to " I (ON)".
Set the stand-by switch on the cleaner to " I (ON)".
The wireless activation button is not
held down correctly.
Hold down the wireless activation button for more
than 6 seconds and then release it when the wire-
less activation lamp blinks in red. Hold down the
wireless activation button for more than 6 seconds
again until the wireless activation button rapidly
blinks in red and then release the button.
MAINTENANCE
CAUTION: Always be sure that the tool is
switched off and the battery cartridge is removed
before attempting to perform inspection or
maintenance.
NOTICE: Never use gasoline, benzine, thinner,
alcohol or the like. Discoloration, deformation or
cracks may result.
To maintain product SAFETY and RELIABILITY,
repairs,anyothermaintenanceoradjustmentshould
be performed by Makita Authorized or Factory Service
Centers, always using Makita replacement parts.
Cleaning the HEPA lter
CAUTION: Do not use the vacuum cleaner
without a lter or continue to use dirty or dam-
aged lter. Vacuumed dust or particles may be
exhausted from the cleaner and they may cause
respiratory disease to the operator.
NOTICE: To keep optimum suction power and
clean exhaust, clean the lter periodically. If
enough suction power is not obtained even after
the cleaning, replace the lter with new one.
NOTICE: To prevent the lter from being dam-
aged, do not use following tools and similar items
for cleaning :
Air duster
High pressure washer
Tools made of hard materials such as a
metallic brush
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Makita DVC265 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Makita DVC265 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Turkish, Spanish as an attachment in your email.

The manual is 6,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info