144
G30/G31 G 25
BURNERS 30/30 mbar 25 mbar
Auxiliary (A) 1,00 0,30 27 50 72 (F1)
Semi-rapid (SR) 1,75 0,45 32 65 94 (Y)
Rapid (R) 3,00 0,75 42 85 121 (F2)
Triple-ring (TC) 3,50 1,50 65 95 138 (F3)
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air vent necessary [m
3
]
Auxiliary (A) 2,00
Semirapid (SR)
3,50
Rapid (R) 6,00
Triple-ring (TC) 7,00
LUBRICATION OF THE GAS TAPS
– In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation maintenance of the appliance must be
fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
TABLE FOR THE CHOICE OF THE INJECTORS
-
Cat: II 2L 3B/P
Nominal
Power
[kW]
Reduced
Power
[kW]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
adjustable
G30/G31 G 20
BURNERS 28-30/37 mbar 20 mbar
Auxiliary (A) 1,00 0,30 27 50 72 (X)
Semi-rapid (SR) 1,75 0,45 32 65 97 (Z)
Rapid (R) 3,00 0,75 42 85 115 (Y)
Triple-ring (TC) 3,50 1,50 65 95 135 (T)
TABLE FOR THE CHOICE OF THE INJECTORS
-
Cat: II 2H 3
+