DESCRIPTION
The hood may be installed in the filtering or the ducting version. Filtering version (Fig. 1): The hood aspirates
the kitchen air saturated with fumes and odours, purifies it through the grease filters and charcoal filters and returns
clean air into the room. For constant efficiency, the charcoal filters must be replaced periodically. The charcoal
filters are not supplied. Ducting version (Fig. 2): The hood aspirates the kitchen air saturated with fumes and
odours, passes it through the grease filters and expels it to the outside through an outlet pipe. With this version
the charcoal filters are not required.
Decide from the outset on the type of installation (filtering or ducting). For greater efficiency, we recommend
you install the hood in the ducting version (if possible).
INSTALLATION
ATTENTION: The appliance should be installed by a qualified operator.
INSTALLATION IN DUCTING VERSION:
1. Before fixing, the disposal duct for air evacuation to the outside must be installed. Use an disposal duct
with: – minimum indispensable length; – minimum possible bends (maximum angle of bend: 90°); – certified material
(according to the State); – an as smooth as possible inside. It is also advisable to avoid any drastic changes
in pipe cross-section. We recommend using a 123 mm diameter pipe for models shown in Figures 3 and 4, and
a 150 mm diameter pipe for the model shown in Figure 5. For air evacuation to the outside, follow all the other
instructions given on the “Warnings” sheet.
2. Prepare a suitable power supply. For the electrical connection, follow all the other instructions on the
“Warnings” sheet.
3. Remove the metal grid or grease filters (make reference to Figures 6, 7 or 8 according to the model you
have purchased):
Fig. 6: remove the metal grid by moving the 2 side fasteners (A).
Fig. 7 and 8: remove the filter/s by moving fastener (B) and turning the filter outwards. Afterwards, remove
the metal grid by moving the 2 side fasteners (C).
4. Cut a hole in the bottom of the pensile cupboard in order to settle the appliance (Fig. 9).
5. To install the appliance, adjust the position of the clasping side spring by means of the proper screw
(Fig. 10D), according to the thickness of the bored panel to which it is going to be anchored.
Insert the appliance in the pensile cupboard and lock it by means of the side spring. Use the holes which
have already been made in the casing of the appliance to definitively fix it by means of 4 extra screws (provided)
- Fig.11.
6. Connect the disposal duct to the air evacuation pipe of the hood. Use a flexible pipe and lock it to the
air evacuation pipe of the hood with a metal hose clamp (pipe and clamp are not provided). Make the electrical
connections.
7. Refit the metal grid and/or the grease filters.
INSTALLATION IN FILTERING VERSION:
Proceed with installation, making reference to the instructions for the extraction version (see points 2, 3, 4,
5), and then follow the instructions below.
Connect the hose to the hood air outlet so the air is conveyed to the top of the wall unit; secure the hose
with a metal clamp (hose and clamp are not provided). Make power connections.
Check whether the charcoal filters have already been fitted. If necessary, proceed to fit these as follows:
rest the charcoal filter on the motor unit by making the pins coincide; turn the charcoal filter until this is fast
(refer to Figures 12, 13 or 14 according to the model purchased).
Refit the metal grid and/or grease filters.
OPERATION
Depending on the model, the unit is equipped with the following controls:
Controls shown in Fig. 15:
Key A = turns the lights on/off. Key B = turns the TIMER on/off: press once
to turn the timer on, therefore, after 5 minutes, the motor cuts out (at the same time the selected speed blinks
on the display); the timer remains on if the motor speed is changed. Display C = - indicates the selected motor
speed (from 1 to 4); - indicates Timer On when the number blinks; - indicates Filter Alarm when the central segments
is on or blinking. Key D = makes the motor work (at the last speed selected); pushing the button again, the speeds
of the motor are sequentially selected from 1 to 4; keeping this button pressed for about 2 seconds shuts down
the motor. Key R = resets the grease filters or charcoal filters; when the filter alarm appears (i.e. when the central
segment on the display goes on), the grease filters must be cleaned (30 hours of operation); when the central
segment starts blinking, the grease filters must be cleaned and the charcoal filters replaced (120 hours of
operation). Obviously, if the hood is not a filtering model and does not have a charcoal filter, clean the grease
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for M-System MU-70 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of M-System MU-70 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info