LUNA 1000-1150-1300-1600 DH GOLD GAS
INSTRUCTION FOR INSTALLATION AND USE
LUNA 1000-1300-1600 CL / CR GOLD GAS (Corner Left /Corner Right)
LUNA 1000-1300-1600 DC GOLD GAS ( Double Corner )
English 11-2012
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
2
V E R Y I M P O R TA N T
I N S T A L L A T I O N
I N S T R U C T I O N S F O R T H E
M - D E S I G N
G A S F I R E P L A C E S
T H E S U P P L I E R T A K E S N O
R E S P O N S B I L I T Y F O R A N Y
P O S S I B L E D A M A G E , P O O R W O R K I N G
A P P L I A N C E S A N D A C C I D E N T A S A
R E S U LT O F I N C O R R E C T I N S TA L L AT I O N
MAINTENANCE GAS FIREPLACE M-DESIGN
THE M-DESIGN GAS FIREPLACES MUST BE
CHECKED every 2 years and GET a
MAINTENANCE. THIS IS ALSO TO MAINTAIN YOUR
WARRANTY. IF THIS WILL BE NOT
OBSERVED, THE WARRANTY FELL.
YOU CAN RELY ON M-DESIGN TO MAKE THIS
CHECK FOR YOU, OR YOU CAN DO THIS BY YOUR-
SELF AND FOLLOW THE METHOD BELOW.
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
3
SUMMARY
1. GENERAL REMARKS .............................................................. 5
2. CONNECTION .......................................................................... 5
3. INSTALLING THE FIREPLACE ............................................. 6
3.1.1 Positioning the replace .................................................. 6
3.1.2 Gas connection .................................................................. 7
3.1.3 Electrical connection ........................................................ 7
4. INSTALLING THE CHIMNEY .............................................. 8-13
5. INSULATION AND FINISHING ........................................... 13
6. CONVECTION CURRENT...................................................... 14-15-16
7. MOUNTING A 3 SIDED FRAME .......................................... 17
8. POSITIONING THE LOGS, DIAMOND, SAPPHIRE AND WHITE PEBBLES 18
1000 DH/CL/CR/DC ................................................................... 19-20
1150 DH ........................................................................................ 21-22
1300 DH/CL/CR/DC ................................................................... 23-24
1600 DH/CL/CR/DC ................................................................... 25-26
9. FIRST-TIME USE ....................................................................... 27
10. SAFETY, ADVICE AND MAINTENANCE ........................ 27
11. STARTPILOT ............................................................................ 28
12. USING THE MANUAL CONTROL .................................... 28
13. SPECIFICATION SHEET ....................................................... 29-30-31-32
DRAWINGS .............................................................................. 33-42
FRAMES .................................................................................... 43-44
14.GUARANTEE ............................................................................ 45
15. CE CERTIFICATION .............................................................. 46
16. SPARE PARTS .......................................................................... 47-50
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
4
OPEN
CLOSING
KEY
IF SOME DUST OR WASTE IS SEEN ON THE WINDOW
( INSIDE AND OUTSIDE ), CLEAN THIS BEFORE THE
FIRST USE OF THE FIREPLACE. CLEANING THE WIN-
DOW IS THE ONLY MAINTENANCE ACTION THAT CAN
BE DONE BY THE CONSUMER
OPEN AND CLOSE THE DOOR
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
5
1. GENERAL REMARKS
This is a moulding of the closed combustion system, designed for the atmosphere and comfort of
your living-room. It constitutes an ecient source of heat and gives the impression of a real chim-
ney re.
The gas with air-vent furnaces are based on the principle of natural extraction from the furnace,
which eliminates ue gas outside and brings in air (oxygen) from outside the house which is neces-
sary for combustion of the gas. It uses to this eect two concentric pipes. The internal pipe ensures
the elimination of burned gases and the external pipe brings in combustion air. The advantage of
this principle is that the equipment works independently of the atmosphere which predominates
in the house.
2. CONNECTION
This appliance must be connected by an approved installer in accordance with the most recent
regulations in force. On the basis of your order specications, this appliance is designed for natural
or propane gas.
Read the instructions before installing and using this appliance. Before installing the furnace, please
check the local regulations about this type of furnace (identication of the type of gas, etc.) and
check that the furnace is adapted to your means of installation.
CAUTION: The furnace must be connected to the type of gas mentioned on the appliance. Never
connect a propane burner to natural gas or vice versa!
It is imperative that the installer sees to the following:
The appliance must be subject to a water tightness test of the gas and elimination of ue
gases.
The concentric pipe, if already available, must be working correctly.
The running of the control valve, lighting of the pilot light, the main burner and the
thermocouple must all be checked.
This appliance has been programmed and factory sealed. The sealed parts cannot be modied. The
appliance may therefore also be installed in watertight accommodation and accommodation equip-
ped with mechanical ventilation. It constitutes ambient heating even in accommodation equipped
with a closed ventilation system.
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
6
3. INSTALLING THE FIREPLACE
After having checked the appliance, you ready to install your appliance.
This is done as follows
3.1.1 POSITIONING THE FIREPLACE
Place the replace on a stable surface using the adjustable feet. Adjust the height of the replace
by turning the bolt ( pic 1 )
pic. 1
pic. 2
A min = 3,5 cm
B = 19 cm
C min = 22.5 cm
The stove may not be placed direct ont the oor to allow natural convection.
The appertures for the air supply ( IN ) is situated underneath the appliances.
Regulating the height of the appliance :
This can be made in two ways.
A regulation by 5 cm ( pic. 1 ) and a ne regulation by screw ( pic.2 ).
The minimal height as from ground to the boom of the appliance is 3,5 cm ( A min ).
The minimal height “C min” will be 22.5 cm, measured as from the ground to 4th side frame ( pic.3 ).
The maximal height as from the ground to the 4th side frame is 45 cm for LUNA DH and max 35cm
for Luna CL/CR/DC
pic. 3
8x 5cm : Luna DH
2x 5cm : Luna CL/CR/DC
Luna CL/CR/DC
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
7
4. INSTALLING THE CHIMNEY
Install the concentric ue duct as indicated by ONTOP - METALOTERM. The only authorised pipes
are ONTOP Metaloterm™.
ONTOP-METALOTERM tested our replace with their conduct and we only garantee a good
working of the replace with those.
Between the external wall of the pipe and the wall or the ceiling, you should anticipate for an
interstice of at least 50mm and protection that is suitable against temperatures of around 130°C.
The passage of the front panel cowl in the external wall must be lled in using silicone mastic.
3.1.3 ELECTRICAL CONNECTION
These appliances are equiped with a radiographic remote control, making an earthened 220V
socket necessary. You should bear in mind that the appliance must be connectes from all
electrical supply for thurpose of service.
ITS OBLIGATORY TO CONNECT AN EARTH CURRENT.
3.1.2 GAS CONNECTION
The appliances are standard delivered with a 1/2” gas solded connection ( g. 1 ). It is always
located at the left-hand side of the appliance. Make sure nothing remains in the gas lines,
since this may easely lead to blockage. An approved gas valve should always be connected to
the appliance, wich must be accesible at all time .
For this you can use a acces door ( pic. 1 next page ). This access door is also used to have
access at the potentiometer (manual controller) and electrical supply.
valve
pic.1
min. Ø18mm
(3/4”)
Ø12mm
g.1
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
8
PIC. 1
PIC. 1 ROOF EXIT ( C31 )
TAB. 2 This is recommanded with a roof exit < 3m
TAB. 1 This is recommanded with a roof exit > 3m
C
Ø 150/100
Appliance C (min) C (max) Restriction HR+ (as from 4m)
1000 DH / CL /CR / DC
3 m 17m Ø 60
as from 2 m : Ø 75
1150 DH
3 m 17m Ø 60
1300 DH / CL/CR / DC
3 m 17m Ø 60
1600 DH / DC
3 m 19m Ø 75
Ø 200/130
Appliance C (min) C (max) Restriction HR+ (as from 3m)
1000 DH / CL / CR / DC
2 m 9m Ø 60
as from 2 m : Ø 75
1150 DH
2 m 9m Ø 60
as from 2 m : Ø 75
1300 DH / CL / CR / DC
2 m 9m Ø 60
as from 2 m : Ø 75
1600 DH / CL / CR / DC
2 m 9m Ø 75
as from 2 m : Ø 75
DH = Double Face CL = Corner Left CR=Corner Right DC = Double Corner
DH = Double Face CL = Corner Left CR=Corner Right DC = Double Corner
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
9
PIC. 2
PIC. 2 ROOF EXIT VIA EXISTING CHIMNEY (C
91
)
TAB. 1
TAB. 2
It is obligatory to use the sanitation set USSAN with placing.
This USSAN piece must be sealed at the roof.
*
*
or
150 (min) / Ø 100
Appliance C (min) C (max) Restriction HR+ (as from 4m)
1000 DH / CL / CR / DC
3 m 17m Ø 60
1150 DH
3 m 17m Ø 60
1300 DH / CL / CR / DC
3 m 17m Ø 60
1600 DH / CL / CR / DC
3 m 19m Ø 75
200(min) / Ø 130
Appliance C (min) C (max) Restriction HR+ (as from 3m)
1000 DH / CL / CR / DC
2 m 9m Ø 60
1150 DH
2 m 9m Ø 60
1300 DH / CL / CR / DC
2 m 9m Ø 60
1600 DH / CL / CR / DC
2 m 11m Ø 75
DH = Double Face CL = Corner Left CR=Corner Right DC = Double Corner
DH = Double Face CL = Corner Left CR=Corner Right DC = Double Corner
or
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
10
USVK13
REDUCTION 200/130 →150/100
PIC. 3 WALL EXIT (C
11
)
PIC. 4 WALL EXIT (C
11
)
0,25
min 1m
A min* = 0,25m
(USVK13)
+ 1m
PIC. 3
Not suitable for
1600 DH/CL/CR/DC
Ø 150/100
WITH REDUCTION USVK13 ON THE APPLIANCE (FIG. 3 )
Appliance A (min) B (min) B (max) Restriction HR+
1000 DH/CL/CR/DC
1,25*m wall exit =A+0,5m
Ø 75
1150 DH
1,25*m wall exit =A
Ø 75
1300 DH/CL/CR/DC
1,25*m wall exit = A
Ø 75
(A) Ø 200/130 in combination with (B) Ø 150/100
WITH REDUCTION USVK13 AFTER 90° CURVE ON HORIZONTAL PART ( FIG. 4 )
Appliance A (min)
Ø 200/130
B (min)
Ø 150/100
B (max)
Ø 150/100
Restriction HR+
1000 DH/CL/CR/DC
1,25m wall exit A+ ”USVK13” +5m
Horiz. < 2m : Ø 75
1150 DH
1,25m wall exit A+ ”USVK13” +4m
Horiz. < 2m : Ø 75
1300 DH/CL/CR/DC
1,25m wall exit A+ ”USVK13” +2,5m
Horiz. < 1m : Ø 75
1600 DH/CL/CR/DC
1,25m wall exit A+ ”USVK13” +0,5m
----------
PIC. 4
DH = Double Face CL = Corner Left CR=Corner Right DC = Double Corner
DH = Double Face CL = Corner Left CR=Corner Right DC = Double Corner
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
11
IMPORTANT : BE CAREFULL EVERY HORIZONTAL PART DOES NOT HAVE AN
NEGATIVE INCLINATION (pic.5) IN DIRECTION OF OUTLET. IT IS EVEN BETTER,
WHEN POSSIBLE, TO HAVE A LITTLE INCLINATION OF 2 OR 3 DEGREES ASCENDING.
TO AVOID RAIN AND CONDENSATION IN TUBE, INSTALL WALL OUTLET LIKE PIC.6.
A
B
Ø 200/130
Appliance A (min) B (min) Restriction HR+ B (max)
1000 DH/CL/CR/DC
1 m wall exit
Ø 70
A+7m
1150 H
1 m wall exit
Ø 75
A+6m
1300 DH/CL/CR/DC
1 m wall exit
Ø 75
A+5m
1600 DH/CL/CR/DC
1 m wall exit
Ø 90
A+3m
DH = Double Face CL = Corner Left CR=Corner Right DC = Double Corner
Pic.5
Pic.6
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
12
Pic. 5 ROOF EXIT with 90° bends
CAUTION : if the vertical lenght is over 3 meter longer than the horizontal lenght, you will
need to place a reduction ring of
Ø 60.
Appliance
Ø 150/100 and Ø 200/130
1000 / 1150
1300 / 1600
for each 90° bend substract 1 m horizontaly or add 1 m verticaly.
1000 / 1150
1300 / 1600
for each 45° / 30° / 15° bend substract 0,5 m horizontaly or add 0,5 m
verticaly.
Pic. 5
Fig. 5 ROOF EXIT with 90° bends
Ø 150/100
WITH REDUCTION USVK13 oN APPLIANCE
Aplliance A (min) B (max) C (min) (A+B+C )max
1000 DH / CL / CR / DC
1,25 m A+C B-A-1m 17m
1150 DH
1,25 m A+C B-A-1 16m
1300 DH / CL / CR / DC
1,25 m A+C B-A-0,5 15m
1600 DH / CL / CR / DC
1,25 m A+C-1m B-A 14m
Ø 200/130
without reduction
Appliance A (min) B (max) C (min) (A+B+C )max
1000 DH / CL / CR / DC
1 m (A+C) + 8m B-A-9m 19m
1150 DH
1 m (A+C) + 7m B-A-8m 18m
1300 DH / CL / CR / DC
1 m (A+C) + 6m B-A-7m 17m
1600 DH / CL / CR / DC
1 m (A+C) + 3m B-A-4m 17m
DH = Double Face CL = Corner Left CR=Corner Right DC = Double Corner
DH = Double Face CL = Corner Left CR=Corner Right DC = Double Corner
WITH REDUCTION USVK13
oN APPLIANCE
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
13
pic. 1
pic. 2
pic. 3
REFERENTIAL DISTANCES IN REGARDS TO FINISHING THE MANTLEPIECE
A very essential point when seing up the Luna Gold is that the distance has to be respected inbet-
ween replace and the nishing material for the mantlepiece such as marble, gipsum,...
For this, a small bended metal sheet that is provided ont the replace ( pic.1 ) , is to be used as the
minimal reference for the distance. The nishing can only ga oas far as this meteal sheet ( pic.2 ).
Don’t remove this ( pic.3 ) ! This allows you to take out the 4th side frame and to let the airow in
the mantelpiece for natural convection.
5. INSULATION AND FINISHING
Once installation is complete, the appliance can be ed. Before doing so, check the tightness of the
gas pipe one more time. Light the appliance and check that it is working: check the tightness of the
gas pipe and the smoke pipe. Once you have checked everything, you can perform the nal insula-
ting and nishing operations.
The built-in part of the furnace tends to be very warm. Please check that the furnace is not too nar-
rowly ed and that there is adequate space for the elimination of hot air. For insulation of the
furnace, we advise you to use M Design insulating plates. You are advised against using any other
insulation product. Inammable materials as well may not be used for the nishing.
Please , follow this instruction. The appliance can overheat if you not apply those instructions.
Errorcode F02 will appear !
The masonry must be raised around the furnace. Because of the expansion of the furnace
during combustion, an interstice of at least 5 mm must be provided on frontside and 4cm on
each side of the appliance. The masonry must not lean against the furnace.
THE APPLIANCE MUST BE SET FREE .
Please pay aention to leave approx. 2 mm inbetween the nishing frame and maconry
( see p.17 , mounting a 3-sided frame, and see page 43,44 and 45 for further information about
installation
min. 5 mm
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
14
The enclosure of the furnace must be provided with ventilation grills or openings allowing for the
elimination of heat by convection. It is possible to have a convection kit ed with the furnace. This
system directs the heat inside the room by means of exible tubes ( dia. 150 mm).
It is obligatory to open at least 2 hot air vents ( for the LUNA 1600 you must open 4) at the top of the
appliance.
For the purposes of the installation of these ducts it is best to go vertically upwards rst for at least 1m
and then to change direction, making a rather wide bend and avoid using a ue terminal grid with
a small clearance because the speed loss that this causes reduces the eciency of the hot air vents.
Place all the ings that you use at the same lengths and angles if possible, otherwise it is possible
that some grids give o more heat than others and, seeing that a hot air pipe functions in a manner
similar to a chimney, the one that is hot rst has the most draught and therefore becomes hot even
more quickly.
Note: a circulation of hot air requires that no under-pressure be created in the room. A grid that is
near the oor (pic 2) sees to it that cold air can be drawn in.
M-design has developed its ideal hot air grids which have many advantages (pic. 1 & 2) and for the
elimination of hot air and the entry of warm air we advise you to use those Design grills made by
M-Design.
The appertures for the air supply “IN” (pic.2) is situated underneath the appliances. The stove may
not be placed direct ont the oor to allow natural convection.
To simplify the mounting of the grids you can use the corner prole (a) wich is furnished with the
grid. This prole is can be mounted on the side of the grid (two lile wholes en screws are provided).
.
6. CONVECTION CURRENT
Please , follow this instruction. The appliance can overheat if you not apply those instructi-
ons. Errorcode F02 will appear !
OUT
pic. 1
(a)
INLET
pic. 2
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
15
Design Grid ( outlet ) with 2 connections
OUTLET
CONVECTION
INLET
CONVECTION
OUTLET
CONVECTION
Inlet Grid convection air
Inlet Grid convection air
Design Grid ( outlet ) with 2 connections
2 dm²
4 dm²
Design Grid ( outlet ) with 4 connections
OR
OR
INLET
CONVECTION
Pic.3
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
16
YOU HAVE TO CONNECT AT LEAST TWO APPERTURES SITUATED AT THE TOP OF THE
APPLIANCE.
FOR THE LUNA 1600, YOU MUST CONNECT 4 APPERTURES.
THE STOVE MAY NOT BE PLACED DIRECT ON THE STOVE MAY NOT BE PLACED DIRECT ON THE
FLOOR, WTHOUT THE FEETS. THIS TO ALLOW NATURAL CONVECTION. THE APPERTURES FOR
THE AIR SUPPLY ARE SITUATED UNDERNEATH THE APLLIANCE.
EVERY OPENING YOU MAKE MUST BE CONNECTED WITH A FLEXIBLE TUBE dia.150MM (see pic.
below). THIS WILL AVOID THE HEATING OF THE ELECTRONIC PART OF THEAPPLIANCE.
IN OTHER CASE YOU WILL HAVE ERRORCODE F02.
GOOD
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
17
7. MOUNTING A 3-SIDED FRAME
PLEASE PAY ATTENTION TO LEAVE APPROX 2 MM INBETWEEN THE FRAME AND
THE FINISHING MATERIAL ( HEAT = EXPANSION)
pic 1
3-sided frame
2,25cm
4 sided frame
(lower piece)
sideframe
upper frame
pic 3
pic 4
pic 5
pic 6
Fireplace is delivered standard with 4sided frame 3,5cm, an upper and 2
sideframes ( see pic. 2 )
Before mounting the 3 sided frame, remove 4 sided frame ( lower piece ) by lift it carefully up. Pull out the
upper frame and in second way the left and right sideframes. Take the left and right side of the 3 sided frame
( 3,5 - 7 or 10 cm ) and slide them in the notches ( see pic 4 ). When those are placed in a good way, you can
adjust the position to the left en to the right and from the the front to the rear. At this way you can make the
frame good surrounding. Mount the upper frame ( pic 5 ) and at last the 4 sided frame ( pic 6 )
pic 2
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
18
Put the big imitation coal pieces around the burner.
Put the lile imitation coal peices on the burner and here and there bet-
ween the big coal pieces.
8. PUTTING IN PLACE THE LOGS, DIAMOND, SAPPHIRE AND WHITE STONES
Please check that the pilot light is switched o and that the furnace has cooled down.
Move the window to the front by pulling it. The window tips open at 45°.
Arrange the materials supplied. In accordance with your order you will have either a set of
logs, diamond, sapphire or white pebbles. There is an adequate supply of materials . Our appliance
is approved with these materials, so please do not use other products. Other decorative products
are prohibited in our appliances. Please do not change the delivered quantities.
ARRANGING THE SET OF LOGS
Caution: do not put anything on the pilot light. To arrange the logs respect the order as follows.
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
19
1
2
3
4
5
6
7
8
9
5
6
7
8
9
1
2
4
3
LUNA 1000
DH/CL/CL/DC GAS
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
20
LUNA 1000
DH/CL/CR/DC GAS
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
21
1
2
4
3
5
6
7
8
9
5
6
7
8
9
1
2
4
3
LUNA 1150 DH GAS
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
22
LUNA 1150 DH GAS
6
7
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
23
1
2
3
4
5
6
7
8
9
5
6
7
9
1
2
4
3
8
10
11
12
10
11
12
LUNA 1300
DH/CL/CR/DC GAS
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
24
LUNA 1300
DH/CL/CR/DC GAS
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
25
1
2
3
4
5
6
7
8
9
5
6
7
9
1
2
4
3
8
10
11
12
10
13
13
11
12
LUNA 1600
DH/CL/CR/DC GAS
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
26
LUNA 1600
DH/CL/CR/DC GAS
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
27
9. FIRST-TIME USE
The masonry and plaster surrounding a recently installed furnace hold a great deal of moi-
sture, which must rst evaporate before commissioning the appliance. If not, the plaster may
crack or split. Ask your installer about the timescale to follow. The rst time you use it, only
make a moderate-sized re.
The rst few times the furnace is used, an unpleasant odour may be apparent. It comes from
the protective paintwork. These emissions are totally harmless. To quickly get rid of these
odours, all you need to do is ventilate the room for a while.
After the rst few res, a light deposit may appear on the window. It comes from the paint-
work. Once the furnace is cold you can get rid of this deposit by using M Design’s Bio-Clean
cleaning product. This product may be used later on for cleaning the window.
The appliance must not be used if the door no longer has a window or with the door open. If
the window is broken or cracked, the appliance must not be used until the window has been
replaced. Contact your M Design reseller.
10. SAFETY, ADVICE AND MAINTENANCE
Have your furnace inspected once a year by a qualied technician.
Please observe the following points:
Closed appliances produce intense heat, which means that all the surfaces of the exter-
nal walls (metal, door frames and windows) become very hot once a certain temperature is
reached. Make sure that young children do not touch the window; this could result in severe
burns.
The logs, ceramic pebbles, a Diamond set and a Sapphire set are delivered with the
furnace. Never put other objects in the ames!
Keep inammable materials a suitable distance from the furnace (min. 1m)!
Never modify the seings yourself! The furnace warranty will then be considered as
invalid, null and void.
Never let children use the remote control without supervision.
Always leave the pilot light on. The appliance is designed in order that the pilot light
goes out automatically every 24 hours and lights instantly. This enables the electronic system
to run down from static electricity.
In the case where the burner goes out for any reason, wait for 3 minutes before religh-
ting the furnace.
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
28
11. STARTPILOT
The M-Design Gas appliance are provided with “Constant startpilot”. After the rst use or when
the winterperiod is coming and
you use the replace daily, you must let the startpilot switch ON. Don’t switch it o after each use.
This startpilot avoids condensation in the replace and protects the whole appliance and even the
electronic parts against humidity.
This startpilot has a very low gasconsumption.
12. USING THE MANUAL CONTROL ( BLACK BOX )
On the user interface, a potentiometer is connected. This one will be used only when
the remote control is broken.
DON’T USE THE POTENTIOMETER SIMULTANIOUSLY WITH THE REMOTE CONTROL
TO SET THE REQUIRED LOAD.
When no ignition with remote control, set potentiometer knob “o” ( turn left ).
Push once on the black push buon. You will hear the starpilot ignition.
Once you see the ame on the starpilot , just turn the potentiometer to the right to regulate
the ames.
To switch o , turn the potentiometer to the left “o” and push once to extinguish the starpilot
ame. Push a second time to swith o the whole replace.
push buon
LED
potentiometer
knob
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
29
13. SPECIFICATION SHEET
Type of Gaz NATURAL GAZ PROPAN / LPG
Categorie
I
2H
I
2L
I
2E+
I
2E
I
3+
I
3B/P
Categorie G25 G20 G31 G30
Type /Type
C
11
, C
31
, C
91
C
11
, C
31
, C
91
C
11
, C
31
, C
91
C
11
, C
31
, C
91
Inlet pressure (mbar) 25 20 30 37 50 28-30
Burner pressure (mbar) 24,2 19,3 29,4 36,2 36,2 28,4
Consumption (m
3
/h)
0,870 0,789 0,264 0,299 0,299 0,226
Injector burner 6 x 0,95 6 x 0,95 6 x 0,6 6 x 0,6 6 x 0,6 6 x 0,6
Injector startpilot 38/33A 38/33A 0.20P3 0.20P3 0.20P3 0.20P3
Rendement (%) 86,4 86,8 73 73 73 73
Nominal Charge (KW) 7 7,5 6,5 7,3 7,3 7,3
Charge (KW) 6,1 6,4 4,7 5,3 5,3 5,3
NOX-emmission classe 5 5 5 5 5 5
Cat. Rendement CE / 1 1 2 2 2 2
LUNA 1000 DH/ CL/CR/DC GOLD gas/gaz
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
30
Type of Gaz NATURAL GAZ PROPAN / LPG
Categorie
I
2H
I
2L
I
2E+
I
2E
I
3+
I
3B/P
Categorie G25 G20 G31 G30
Type /Type
C
11
, C
31
, C
91
C
11
, C
31
, C
91
C
11
, C
31
, C
91
C
11
, C
31
, C
91
Inlet pressure (mbar) 25 20 30 37 50 28-30
Burner pressure (mbar) 24,2 19,3 29,4 36,2 36,2 28,4
Consumption (m
3
/h)
0,870 0,789 0,264 0,299 0,299 0,226
Injector burner 6 x 1 6 x 1 6 x 0,6 6 x 0,6 6 x 0,6 6 x 0,6
Injector startpilot 38/33A 38/33A 0.20P3 0.20P3 0.20P3 0.20P3
Rendement (%) 83 86,2 73 73 73 73
Nominal Charge (KW) 7 7,5 6,5 7,3 7,3 7,3
Charge (KW) 6,1 6,4 4,7 5,3 5,3 5,3
NOX-emmission classe 5 5 5 5 5 5
Cat. Rendement CE / 1 1 2 2 2 2
LUNA 1150 DH GOLD gas/gaz
13. SPECIFICATION SHEET
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
31
Type of Gaz NATURAL GAZ PROPAAN / LPG
Categorie
I
2H
I
2L
I
2E+
I
2E
I
3+
I
3B/P
Categorie G25 G20 G31 G30
Type /Type
C
11
, C
31
, C
91
C
11
, C
31
, C
91
C
11
, C
31
, C
91
C
11
, C
31
, C
91
Inlet pressure (mbar) 25 20 30 37 50 28-30
Burner pressure (mbar) 24 19,2 29,2 36,1 36,1 28,2
Consumption (m
3
/h)
1,132 1,026 0,344 0,389 0,389 0,295
Injector burner 6 x 1,10 6 x 1,10 6 x 0,65 6 x 0,65 6 x 0,65 6 x 0,65
Injector startpilot 38/33A 38/33A 0.20P3 0.20P3 0.20P3 0.20P3
Rendement (%) 85 87 70 70 70 70
Nominal Charge (KW) 9,2 9,7 8,4 9,5 9,5 9,5
Charge (KW) 8,0 8,4 5,9 6,7 6,7 6,7
NOX-emmission classe 5 5 5 5 5 5
Cat. Rendement CE / 1 1 2 2 2 2
LUNA 1300 DH/CL/CR/DC GOLD gas/gaz
13. SPECIFICATION SHEET
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
32
Type of Gaz NATURAL GAZ PROPAN / LPG
Categorie
I
2H
I
2L
I
2E+
I
2E
I
3+
I
3B/P
Categorie G25 G20 G31 G30
Type /Type
C
11
, C
31
, C
91
C
11
, C
31
, C
91
C
11
, C
31
, C
91
C
11
, C
31
, C
91
Inlet pressure (mbar) 25 20 30 37 50 28-30
Burner pressure (mbar) 23 18,8 29 36 36 28,1
Consumption (m
3
/h)
1,393 1,262 0,423 0,478 0,478 0,363
Injector burner 6 x 1,25 6 x 1,25 6 x 0,75 6 x 0,75 6 x 0,75 6 x 0,75
Injector startpilot 38/33A 38/33A 0.20P3 0.20P3 0.20P3 0.20P3
Rendement (%) 85 85,2 68 68 68 68
Nominal Charge (KW) 11,2 11,9 10,3 11,7 11,7 11,7
Charge (KW) 9,5 10,1 7 8 8 8
NOX-emmission classe 5 5 5 5 5 5
Cat. Rendement CE / 1 1 2 2 2 2
LUNA 1600 DH/CL/CR/DC GOLD gas/gaz
13. SPECIFICATION SHEET
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
33
LUNA 1000 DH GOLD gas/gaz
*
*
Connection Gas
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
34
LUNA 1000 CL/CR GOLD gas
*
Connection gas on the left for the CR
Connection gas on the right for the CL
CL : Corner Left
CR : Corner Right
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
35
LUNA 1000 DC GOLD gas
Connection Gas
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
36
LUNA 1150 H GOLD gas
*
*
Connection Gas
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
37
LUNA 1300 DH GOLD gas
*
*
Connection Gas
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
38
LUNA 1300 CL/CR GOLD gas
CL : Corner Left
CR : Corner Right
CR
*
*
*
Connection gas on the left for the CR
Connection gas on the right for the CL
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
39
LUNA 1300 DC GOLD gas
Connection gas
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
40
LUNA 1600 DH GOLD gas
*
*
Connection gas
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
41
LUNA 1600 CL/CR GOLD gas
CL : Corner Left
CR : Corner Right
*
*
Connection gas on the left for the CR
Connection gas on the right for the CL
CR
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
42
LUNA 1600 DC GOLD gas
Gas Connection
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
43
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
44
1000-1300-1600 DC ( GSX)
Afwerking zonder 4-zijdige kader
Finition sans cadre 4 cotés
Finishing without 4-sided frame
Ausfürung ohne 4-seite Rahme
Toestel standaard geleverd met onderlat 3,5cm samen met bovenlijst en zijlijsten
Appareil livré standard avec baguette de 3,5 cm ensemble avec baguette supérieur et baguettes latérales
Appliance standard delivered with lower frame 3,5 cm, together with the small upper and side frames
Gerät wird standard geliefert mit unterleiste 3,5 cm und leiste oben und seite.
1000 DC
1300 DC
1600 DC
A(mm)
1008
1308
1608
B(mm)
367
367
367
C(mm)
371
371
371
D(mm)
55
55
55
E(mm)
35
35
35
1000 DC
1300 DC
1600 DC
A(mm)
1078
1378
1678
B(mm)
402
402
402
C(mm)
406
406
406
D(mm)
90
90
90
E(mm)
70
70
70
1000 DC
1300 DC
1600 DC
A(mm)
1148
1448
1748
B(mm)
437
437
437
C(mm)
441
441
441
D(mm)
125
125
125
E(mm)
105
105
105
4-zijdige kader 7cm/ Cadre 4-coté 7cm/4-sided frame 7cm/4-seite Rahme 7cm
4-zijdige kader 10,5cm/ Cadre 4-coté 10,5cm/4-sided frame 10,5cm/4-seite Rahme 10,5cm
4-zijdige kader 3,5cm/ Cadre 4-coté 3,5cm/4-sided frame 3,5cm/4-seite Rahme 3,5cm
4-zijdige kader / Cadre 4-cotés / 4-sided frame / 4-Seite Rahmen 1000/1300/1600 DC
1000 DC
1300 DC
1600 DC
A(mm)
1008
1308
1608
B(mm)
955
1255
1555
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
45
14. GUARANTEE
This page is your warranty card.
The guarantee is only valid for faults caused by construction defects or defects in the parts used to
build the furnace.
M-Design oers a 12 month guarantee on all electronic parts and a 8 year guarantee on the furnace
construction.
Caution: The following items are always excluded from the guarantee:
- The glass, door, joints and internal decor.
- The defects which occur are fully or partially a consequence of
Non respect of the order, installation and maintenance instructions
Assembly, installation or repair by a third-party, including the buyer
Heat cracks which normally occur in the mantel
In cases where changes have been made to the furnace without our consent
In cases where the buyer cannot show his/her warranty card with the purchase invoice.
Likewise where the guarantee and/or the invoice show(s) signs of tampering or forgery (crossed out
date, illegible, modications).
In the case you would like to make use of the manufacturer’s warranty, you should contact your
reseller in the rst instance. Please take good care of your purchase invoice and warranty card and
store them in a safe place.
SERIAL NUMBER
IDENTIFICATION BOARD ( till 11/2012 )
this is situated at the left side of the appliance.
SERIAL NUMBER
Your serial number :
......................................................
8
M-DESIGN BENELUX BVBA
TORHOUTSESTEENWEG 222A
8210 ZEDELGEM
As from 11/2012 : under the 4sided frame
open the door :
in left or right corner
engraved number
IDENTIFICATION BOARD
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
46
15. CE CERTIFICATION
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
47
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
48
16. SPARE PARTS DOUBLE SIDED
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
49
SPARE PARTS CORNER GAS
LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
50
SPARE PARTS DOUBLE CORNER
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for M-design LUNA GAS 1300 DH - CL - CR - DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of M-design LUNA GAS 1300 DH - CL - CR - DC in the language / languages: English as an attachment in your email.

The manual is 3,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of M-design LUNA GAS 1300 DH - CL - CR - DC

M-design LUNA GAS 1300 DH - CL - CR - DC User Manual - German - 55 pages

M-design LUNA GAS 1300 DH - CL - CR - DC Usermanual and installation guide - Dutch, French - 50 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info