7
4. INSTALLING THE CHIMNEY
Install the concentric ue duct as indicated by ONTOP - METALOTERM. The only authorised pipes
are ONTOP Metaloterm™.
ONTOP-METALOTERM tested our replace with their conduct and we only garantee a good
working of the replace with those.
Between the external wall of the pipe and the wall or the ceiling, you should anticipate for an
interstice of at least 50mm and protection that is suitable against temperatures of around 130°C.
The passage of the front panel cowl in the external wall must be lled in using silicone mastic.
3.1.3 ELECTRICAL CONNECTION
These appliances are equiped with a radiographic remote control, making an earthened 220V
socket necessary. You should bear in mind that the appliance must be connectes from all
electrical supply for thurpose of service.
ITS OBLIGATORY TO CONNECT AN EARTH CURRENT.
3.1.2 GAS CONNECTION
The appliances are standard delivered with a 1/2” gas solded connection ( pic. 1 ). It is always
located at the back side of the appliance. Make sure nothing remains in the gas lines,
since this may easely lead to blockage. An approved gas valve should always be connected to
the appliance, wich must be accesible at all time .
For this you can use a acces door ( pic. 1 next page ). This access door is also used to have
access at the potentiometer (manual controller) and electrical supply.
pic.1
pic.1
valve
Ø12mm
Ø18mm
(3/4”)
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for M-design LUNA 1000 RD GOLD gas at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of M-design LUNA 1000 RD GOLD gas in the language / languages: English as an attachment in your email.

The manual is 1,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of M-design LUNA 1000 RD GOLD gas

M-design LUNA 1000 RD GOLD gas Usermanual and installation guide - Dutch, French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info