38 User Guide Oxygen 88
The controls on Oxygen 88 allow assignment of either a RPN/NRPN coarse message, or a RPN/NRPN fine
message, but not both simultaneously. In practical use, this means:
Assigning an RPN/NRPN coarse message to an Oxygen control allows to access values throughout the
entire range of 16384 steps while skipping 128 steps with every value transmitted
(0; 129; 258; 387; 516; 645;...;16384).
Assigning an RPN/NRPN fine message to an Oxygen control allows access to the first 128 values of the
entire range (0-127 of 16384).
In most cases, it is preferable to assign the RNP/NRPN coarse message, unless two Oxygen controls are
dedicated to be operated together for simultaneous control of the RPN/NRPN coarse and fine parameters.
Many data sheets for synthesizers make use of NRPN messages and will give the LSB and MSB values that
should be entered for Data 2 and Data 3. Some manuals may only give the hex values, but Oxygen requires the
decimal value to be entered. See Appendix E for a hex to decimal conversion chart.
SysEx
System Exclusive (SysEx) messages were defined in the MIDI specification to allow control of individual devices via
MIDI. The format of SysEx messages allows virtually any function to be performed via MIDI if the receiving device can
read and translate the message. This allows devices to send audio sample memory data, memory dumps, controller
settings, and much more. It also allows the controllers of one device to be controlled by another.
It is not possible to program your own specific SysEx message into the Oxygen controller. However, several useful
SysEx messages are pre-programmed into the keyboard. They can be accessed by assigning the appropriate MIDI
controller number to a control.
A SysEx message is not transmitted on any specific channel. All SysEx messages contain a Device ID, which is used
to single out devices to respond to the SysEx message. All other devices are ignored. If you are using a SysEx
message with your Oxygen keyboard, the Global Channel is ignored. When you press the Channel Assign key, you will
enter a Device ID instead. This is indicated by the fact that the LED screen displays a 3-digit number, not a 2-digit
number proceeded by a "c."
Device IDs run from 00 to 127. 127 is the default device number setting for Oxygen 88. This setting transmits the SysEx
message to all devices.
It is not possible to program the controls on Oxygen 88 with your own SysEx messages, there are software applications
that can receive a MIDI input signal and translate it into a different, user-specified message. You can program your
custom SysEx messages into the translator software, and then translate the incoming data from the keyboard to your
custom SysEx message.
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for M-Audio Oxygen 88 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of M-Audio Oxygen 88 in the language / languages: English as an attachment in your email.

The manual is 1,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of M-Audio Oxygen 88

M-Audio Oxygen 88 Quick start guide - English, German, French, Italian, Spanish - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info