4 Front Panel Key Combinations
Aurora functionality can be altered via its front panel with key combinations or by depressing certain
front panel buttons for 500ms. Here are some of the possible modifications as of firmware rev 22:
Button Action Result
METER
Depress METER button for
500ms
Enables Horizontal Metering Mode. Meters
will display activity for Analog Out 1-4 (if
METER switch is set to “ANALOG”), or
Digital Out 1-4 (if METER switch is set to
“DIGITAL”)
SYNC SOURCE
Depress SYNC SOURCE
button for 500ms
Toggles “Synchrolock” between ON and
OFF
TO ANALOG OUT
Depress TO ANALOG OUT
button for 500ms
With LT-HD card installed in Aurora,
Toggles between 16 and 32 channel mode
(see LT-HD User Manual)
TRIM
Press and hold TRIM button
while turning on
POWER/STANDBY switch
Displays firmware revision in the meter
display (combine rapidly flashing number
from input and output row)
STANDBY/POWER
Press STANDBY/POWER
switch while AC power is
applied
Toggles power up mode between Standby
and On
SAMPLE RATE
Press SAMPLE RATE button
while AC power is applied
Restores factory defaults
TRIM/AES MODE
Press TRIM/AES MODE
button while AC power is
applied
Enables DUAL WIRE SELECT mode, where
the Dual Wire state for the Digital I/O can be
set.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lynx Aurora 16 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lynx Aurora 16 in the language / languages: English as an attachment in your email.

The manual is 1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info