541010
18
Zoom out
Zoom in
Previous page
1/151
Next page
LX90xx system Version 4.0 February 2014
Page 18 of 151
TE/P
static
TE tube
P
static
Static
P
total
Pitot or Total pressure
If the P
total
and Static are connected the wrong way around there will be no
integrator reading (average climb) during the flight.
The main display unit is connected to 12 Volt power via the 15-pin SUB-D connector. The
main display unit, vario unit and other vario indicators are connected via the RS485 bus and
the connectors are labelled with “RS485” at each end.
Please ensure that both units are connected correctly before the first power on. The power
wires (red and blue) should be connected to the main display unit.
Even though there is an automatic fuse in the instrument it is VERY IMPORTANT
to use an external fuse (max. 3A). Power supply cables should use a minimum of
0.5 mm² wires. To prevent damage to the main display unit after a short circuit
on the RS485 bus there is an automatic fuse.
If a short circuit occurs then the 57 mm unit will appear not to work anymore. The reason
is not the defect of 57 mm unit it is due to the hot automatic fuse. Turn off the system
and wait for the automatic fuse to cool down.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for LX NAV LX9000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of LX NAV LX9000 in the language / languages: English as an attachment in your email.

The manual is 12,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of LX NAV LX9000

LX NAV LX9000 User Manual - German - 175 pages

LX NAV LX9000 User Manual - Dutch - 150 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info