back of thin
fiberglass panels
to
support
the X-1550.
If the desired location is closer
than 18:: to a
magnetic compass,
a trial run
should be made with
the unit
in
operation
to be sure
that the
compass readings
are not
affected.
Figure
3
BE SURE to insert
the two rub-
ber
grommets
on
gimbal
bracket.
The
larger
side
(larger
diameter)
of
grommet goes
on inside of
gimbal
bracket so that it
is sand-
wiched between
gimbal
bracket
and sonar instrument
(see
draw-
ings).
The
grommets provide
fric-
tion to hold the unit at
the desired
angle.
Power Connections
Twelve volt
DC
power
for the
depth
sounder should be
supplied
by
the
boat's 12-volt electrical
sys-
tem. The
power
cable
may
be at-
tached to an
accessory
or
power
buss,
but
if
you
have
problems
with
electrical
interference,
the
cable should be attached
directly
to the
battery.
If a
longer
cable is
required,
use
ordinary
#18
lamp
cord available
at
any
hardware or electronic
sup-
ply
store.
Splices
should
be sol-
dered. If this can't be
done,
use
crimp-type splices. Tape
all
splices
with
electrical
tape.
An in-line fuse holder with fuse
is
supplied
with the X-1550. Be
certain to install this fuse holder
as close to the
power
source as
possible.
This will
protect
both
the sonar unit and the
power
cable in the event a short occurs.
Crimp
connectors are
supplied
to
attach the fuse holder to the
power
cable. The red or white
wire in the
power
cable is the
positive
conductor. The black wire
is the
ground
conductor.
The
graph
is
protected
from ac-
cidental
polarity
reversals and no
damage
will
occur if the wires are
reversed. The unit
will not
operate,
however,
until the
proper polarity
is
applied.
Ill
BASIC OPERATION
On-off and
Sensitivity
Control
Rotate the On/Off knob
clockwise
to turn the unit on. The
Sensitivity
knob works much like the
volume
control on a
radio,
that
is,
weaker
signals
will be detected with
higher settings
of the knob. When
cruising:
or at
other times when
just simple
bottom-contour infor-
mation is
desired,
the
Sensitivity
setting
can be low. In
deep
water
or over
soft,
muddy bottoms,
(which produce
weak
echoes),
the
setting
will have to be
higher.
mediately
be
seen. Use
only
the
amount
of SCC
required
to reduce
the
clutter, as fish
signals
can be
eliminated also.
To turn the 5CC
function
OFF,
press 0,
MARK/SCC. The SCC
value
(1, 2,
or
3)
can be
changed
or turned OFF
at
any
time.
Feet, Fathoms,
Meters
The X-15 will
display
the
depth
in
feet, fathoms,
or meters.
Al-
though
the unit will revert back to
the feet mode whenever
power
is turned
off,
it is
simple
to
change
to
any
mode
you
wish
by pressing
1 and 3 for
feet
4 and 6 for
fathoms,
and 7 and 9 for meters.
These
keys
must be
pressed
simultaneously
for this feature to
work.
When the unit is in the
Feet
mode,
only
one
U
will
be dis-
played
at the bottom of the
chart
paper every
few inches. In the
Fathom mode two U's will be dis-
played.
Three
L's
will be
printed
on the Meter mode.
Example: Display
Meters
Press: 7 and 9
simultaneously
Result:
Figure
41
El 0—
,8
-
12
-
-
lb
-
20—
13y looking
at the number of
U
's,
one can determine the
depth display
mode that the unit is
in, i.e.,
Feet
-
U
,
Fathoms
-
Ii
U,
or Meters
-
I.! U U.
Transmit and Print Alternate
When
the X-1 550 is first turned
on,
the Transmit and
Print Alter-
nate function is
enabled automat-
ically.
This causes
the
stylus
to
print
on
every
other revolution
and the transmitter is
also
trig-
gered
on
every
other revolution.
This
accomplishes
three
things:
1. Since the
stylus only prints
ev-
ery
other
revolution,
the re-
corded information is not
squeezed together
into a
very
small area. This allows better
records at slower
paper
speeds.
Also,
the scale num-
bers are
spread
out
more,
so
they
are more
legible.
The
pa-
per speed
is also slowed down
slightly.
2.
Prevents the
possibility
of
'wrap
around". This is the un-
desirable
occurrence of the
second or
third bottom echo
printed
on the
paper
at the
top
or middle
of the
page. Many
times this can
interfere with
fish or other
targets
that
you
wish to see.
(See
Figures
46
and
47.)
3. Reduces the
reverberation ef-
fect. This
happens
mainly
on
lower
frequency units,
al-
though
it does
sometimes
show
up
on
high
frequency
graphs.
To disable the Transmit and
Print
Alternate
mode,
press
the
UPPER LIMITand LOWER LIMIT
2
keys
simultaneously.
If
you
wish
to turn
the function back
on,
sim-
lb
ply press
the UPPER LIMIT and
LOWER LIMIT
keys again.
This
will cause
the unit to transmit and
print
on
every
stylus
rotation and
speeds
the
paper
up slightly.
Transmit Pulse
Width
The noise
suppression
system
in the X-1 550 is a
patented pulse
width discrimination
suppression
circuit,
and is the
same as the one
-
LI
Ground
(Negative)
Figure
4
4
17
PDF compression, OCR, web-optimization with CVISION's PdfCompressor
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lowrance X-1550 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lowrance X-1550 in the language / languages: English as an attachment in your email.

The manual is 0,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info