5.5.2 XTE ALARM
Disables (Off) or specifies the distance your Cross Track Error (XTE) can
vary before the sound of an alarm or disables the XTE Alarm (Off). The default
setting is Off.
'MENU' + "ADVANCED SETTINGS" + 'ENTER' + "ALARMS" + 'ENTER' + "XTE
ALARM" + 'ENTER'
5.5.3 ANCHOR ALARM
This function allows inserting of the limit of anchor dragging: beyond that,
the alarm is activated. The chart plotter computes the distance between the current
GPS position and the GPS position saved at the activation of the anchor alarm in the
menu. If the computed distance exceeds the value set in the menu, the chart plotter
shows the alarm message and starts the acoustic alarm. The default setting is Off.
'MENU' + "ADVANCED SETTINGS" + 'ENTER' + "ALARMS" + 'ENTER' + "AN-
CHOR ALARM" + 'ENTER'
5.5.4 DEPTH ALARM
Specifies the depth or disables the Depth Alarm. The default setting is Off.
'MENU' + "ADVANCED SETTINGS" + 'ENTER' + "ALARMS" + 'ENTER' +
"DEPTH ALARM" + 'ENTER'
5.5.5 EXTERNAL ALARM O
NLY
F
OR
PANORAMIC & COMPACT 8 HD / HD F
ISH
Allows triggering an external alarm device. You can enable (On) or disable
(Off) the External Alarm. The default setting is On.
'MENU' + "ADVANCED SETTINGS" + 'ENTER' + "ALARMS" + 'ENTER' + "EX-
TERNAL ALARM" + 'ENTER'
5.5.6 GROUNDING ALARM (GUARDIAN TECHNOLOGY)
The chart plotter is provided with a function that, by querying the map's data,
verifies potential danger to navigation due to shallow water, land, rocks, obstructions
and shoreline constructions. The maps are scanned periodically (every 10 seconds).
When the Grounding Alarm is active, the chart plotter scans an area in front
of the boat. This area is identified by a triangle drawn in front of the boat icon whose
direction is determined by the current boat heading. The length of the triangle is
user selectable and its angle is 30°. If any of the above objects are found, the chart
plotter notifies the danger on a dedicated warning message box in the Grounding
Alarm Report Page (see Par. 5.5.8).
The Grounding Alarm is switched Off by default after a Master Reset. Once
93


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lorenz PANORAMIC 8 HD at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lorenz PANORAMIC 8 HD in the language / languages: English as an attachment in your email.

The manual is 3,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info