9.2 INFORMATION FOR PROFESSIONAL ELECTRICIANS (E 205)
400 VOLT (3-PHASE) CONNECTIONS
yellow/green - earth
blue - 1 live phase
brown - 1 live phase
9.3 CONNECTIONS E 260
brown = R (L1)
black = S (L2)
blue = T (L3)
yellow/green = earth
You can weld with a power output of 400 V/50 Hz/3 phase or 230 V/50 Hz/
3 phase.
The switch high/low is used by extreme low welding values (turn the switch to
“low”) or extreme high welding values (turn the switch to “high”).
10.0 TECHNICAL DATA
Type E 100
Winding aluminium
Volt 230
KVA 3,7
Ignition voltage 33-38
Adjusting range (amp) 60-85
Electrode φ (mm) 1,6-2,5
Dimensions (lxwxh) (mm) 260 x 195 x 185
Weight (kg) 9,5
Ordernumber 76055
Type E 145
Winding copper
Volt 230
KVA 3,8
Ignition voltage 41-46
Adjusting range (amp) 30-105
Electrode φ (mm) 1,6-2,5
Dimensions (lxwxh) (mm) 350 x 270 x 240
Weight (kg) 18
Ordernumber 76056
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Load Up 76005 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Load Up 76005 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info