Chapter 6: Configuring the ADSL2+ Gateway
The Setup - Basic Setup Tab
ADSL2+ Gateway with VoIP
Connect on Demand: Max Idle Time. You can configure the Gateway to disconnect the Internet
connection after it has been inactive for a specified period of time (Max Idle Time). If your Internet
connection has been terminated due to inactivity, Connect on Demand enables the Gateway to
automatically re-establish your connection as soon as you attempt to access the Internet again. To use
this option, click the Connect on Demand radio button. In the Max Idle Time field, enter the number of
minutes you want to have elapsed before your Internet connection terminates.
Keep Alive: Redial Period. If you select this option, the Gateway will periodically check your Internet
connection. If you are disconnected, then the Gateway will automatically re-establish your connection. To
use this option, click the Keep Alive radio button. In the Redial Period field, specify how often you want
the Gateway to check the Internet connection. The default Redial Period is 20 seconds.
Bridged Mode Only
If you are using your Gateway as a bridge, which makes the Gateway act like a stand-alone modem, select
Bridged Mode Only. All NAT and routing settings are disabled in this mode.
Optional Settings (required by some ISPs)
Host Name and Domain Name. These fields allow you to supply a host and domain name for the Gateway.
Some ISPs require these names as identification. You may have to check with your ISP to see if your
broadband Internet service has been configured with a host and domain name. In most cases, you can leave
these fields blank.
MTU and Size. The MTU (Maximum Transmission Unit) setting specifies the largest packet size permitted for
network transmission. Select Manual and enter the value desired in the Size field. It is recommended that
you leave this value in the 1200 to 1500 range. By default, MTU is configured automatically.
Network Setup
Router IP. The values for the Gateway’s Local IP Address and Subnet Mask are shown here. In most cases,
keep the default values.
Local IP Address. The default value is 192.168.1.1.
Subnet Mask. The default value is 255.255.255.0.
Network Address Server Settings (DHCP). Configure the Gateway’s Dynamic Host Configuration Protocol
(DHCP) settings in this section.
Figure 6-10: Optional Settings
Figure 6-9: Bridged Mode Only
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Linksys AG310 ADSL2 plus Gateway with VOIP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Linksys AG310 ADSL2 plus Gateway with VOIP in the language / languages: English as an attachment in your email.

The manual is 12,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info