OWNER’S & INSTALLATION
MANUAL
AIR CONDITIONER
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly..
WIRED REMOTE CONTROLLER
PREMTB100, PREMTBB10, CREMTB100
Copyright © 2016 - 2018 LG Electronics Inc. All Rights Reserved.
MFL69312302
Rev.09_111918
ENGLISH
FRANÇAIS
ITALIANO DEUTSCH ESPAÑOL
РУССКИЙ ЯЗЫК
POLSKI
PORTUGUÊS
中文
ČEŠTINA
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 1000
3
IMPORTANT SAFETY INSTRUCTIONS
• Do not cool excessively indoors. This may consume more electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the
air flow or reduce the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
TIPS FOR SAVING ENERGY
2
ENGLISH
Here are some tips that will help you minimize the power consumption when you use the air
conditioner. You can use your air conditioner more efficiently by referring to the instructions
below:
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak
performance of your product
WARNING
This symbol indicates potentially hazardous situation which, if not avoided could result in death or
serious injury.
CAUTION
This symbol indicates a potentially hazardous situation which, if not avoided, may result in minor
or moderate injury.
WARNING
Installation
• For electrical work, contact the dealer, seller, a qualified electrician, or an authorized service Center.
- Do not disassemble or repair the product. There is risk of fire, electric shock, explosion, equipment
malfunction, or injury.
• Request to the service center or installation specialty store when reinstalling the installed product.
- There is risk of fire, electric shock, explosion, equipment malfunction, or injury.
• Do not disassemble, fix, and modify products randomly.
- There is risk of fire, electric shock, explosion, equipment malfunction, or injury.
• The product shall be installed according to the national standards and local code.
• Apply totally enclosed noncombustible conduit in case of local building code requiring plenum.
• Use appropriate unit mounting procedures.
• Avoid direct sunlight.
• Avoid moist areas.
In-Use
• Do not place flammable objects close to the product.
- There is risk of fire, electric shock, explosion, equipment malfunction or injury.
• Do not allow product to get wet.
- There is risk of fire, electric shock, explosion, equipment malfunction or injury.
• Avoid dropping the product.
- There is risk of fire, electric shock, explosion, equipment malfunction or injury.
• If product gets wet, contact your dealer or authorized service center.
- There is risk of fire, electric shock, explosion, equipment malfunction, or injury. If the instructions
are not followed, it may cause death or severe injury of the user.
• Do not use sharp or pointed objects on product.
- There is risk of fire, electric shock, explosion, equipment malfunction or injury.
• Do not touch or pull the lead wire with wet hands.
- There is risk of product breakdown or electric shock.
!
!
!
TIPS FOR SAVING ENERGY
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 2
5
2 TIPS FOR SAVING ENERGY
3 IMPORTANT SAFETY IN-
STRUCTIONS
8 DESCRIPTION
9 READ BEFORE OPERATING
THE CONTROLLER
9 Menu Structure
14 DESCRIPTION OF THE OP-
ERATION
14 Main screen
14 Menu screen
15 Setting screen
15 Popup screen
16 Monitoring / Sub function screen
17 Interface screen
17 Returning to the screen
18 OPERATION SETTING
18 On / Off
18 Operation mode
19 Cooling Operation
20 Heating Operation
21 Dry Operation
22 Fan Only Operation
23 AI / Auto operation
24 Dual setpoint auto operation
25 Power Cool Operation
25 Power Heat Operation
26 OPERATION SETTING -
VENTILATOR
26 Operation mode
27 TEMPERATURE SETTING
27 Controlling Desired Temperature
28 Check Room Temperature
29 WIND SETTING
29 Fan speed control
29 Fan speed control - ventilation
29 Air flow control
30 HOME LEAVE SETTING
30 Home leave (Unoccupied Mode)
31 HOLD SETTING
31 Hold
32 ADDITIONAL OPERATION –
VENTILATION
32 Additional operation
33 EXTERNAL EQUIPMENT
CONTROL SETTING
33 External equipment control
34 PLASMA PURIFICATION
SETTING
34 Plasma Purification
35 OVERRIDE CONTROL SET-
TING
35 Override control
36 MONITORING SCREEN
36 How to enter fine dust status screen
37 Fine dusts status
38 SUB FUNCTION SETTING
38 Sub function entrance and setting method
39 Energy Saving Setting
40 Plasma Purification Setting
41 Fan Auto Setting
42 Humidification setting
43 Electric Heater Setting
44 Robot Cleaning Setting
45 Ventilation kit Setting
46 Comfort Cooling Setting
47 ZONE CONTROL SETTING
47 Zone Control
48 LOCK SETTING
48 How to enter lock setting
48 Lock setting – all, on/off, mode, tempera-
ture range lock
49 TIMER SETTING
TABLE OF CONTENTS
TABLE OF CONTENTS
CAUTION
In-use
• Do not clean using powerful detergents like solvent but use soft cloths.
There is risk of fire, electric shock, explosion, equipment malfunction or deformation.
• Do not press the screen using powerful pressure.
There is risk of product break-down or malfunction.
!
IMPORTANT SAFETY INSTRUCTIONS
4
ENGLISH
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 4
TABLE OF CONTENTS
76
TABLE OF CONTENTS
ENGLISH
49 Timer entrance and setting method
50 Simple timer
51 Sleep timer
52 Turn-off Reservation
53 Turn-on Reservation
54 SCHEDULE SETTING
54 How to enter schedule
55 Daily Schedule
56 Schedules & Edit
57 Schedules & Edit – Add schedule
58 Exception day
59 ENERGY (air conditioner /
DX ventilator)
59 How to enter energy
60 Instantaneous power check
61 Energy consumption
63 Energy saving - Temperature Setback Timer
64 Energy saving - Time Limit Control
65 Energy setting - outdoor unit capacity set-
ting
66 Energy setting - target instantaneous power
setting
67 Energy setting - target power consumption
68 Energy setting - target operation time
69 Energy setting - Alarm Popup Setting
70 Energy setting – Usage data initialization
71 FUNCTION SETTING
71 How to enter function setting
72 Function Setting
73 Vane angle control setting
74 Elevation grill setting
75 Robot cleaning setting
75 Auto dry setting
76 Filter sign check and initialization
77 Change temperature setting
78 Dead Band
79 Wi-Fi pairing setting
80 Zone Name setting
81 Override Set Time Setting
82 Home Leave Set Temperature Setting
83 Comfort cooling setting
83 ODU Refrigerant Noise Reduction setting
84 Defrost mode setting
85 Smart load control(SLC) setting
86 Low noise mode time setting
87 Advanced fan speed “Auto” setting
88 Delay time (exclusive for ventilation)
89 Midnight air cooling (ventilation interface)
90 Human detection mode setting
92 Discharge direction
92 CO
2 Fan Control(general ventilator)
93 USER SETTING
93 How to enter user setting
93 User Setting
94 Language setting
95 Setpoint Type Setting
96 Temperature unit setting
97 Screen saver timer setting
97 LCD brightness in idle setting
98 External device setting
98 External device use
99 External device types
100 On condition / Off condition
101 Date setting
102 Time setting
103 Summer time setting
104 Password setting
105 Schedule initialization
106 Theme setting
107 Humidity display
108 System restart
109 SERVICE SETTING
109 How to enter service setting
109 Service setting
110 Service contact
111 Model information
112 RMC Version Information
113 Error history
114 Open source license
115 INSTALLATION
115 Installation of Remote Controller
117 Group control
119 INSTALLATION METHOD
TO USE EXTERNAL DEVICE
119 Cable connection method to use external
device
120 AIR CONDITIONER AND
VENTILATION INTERFACE
121 INSTALLER SETTING
121 How to enter installer setting
122 Installer setting – air conditioner
124 Installer setting - ventilator
125 Test run setting (air conditioner / DX venti-
lator)
126 Central control address setting (air condi-
tioner / general, DX ventilator)
127 ESP setting (air conditioner / general, DX
ventilator)
128 Temperature sensor(2TH) setting (air condi-
tioner / DX ventilator)
129 Ceiling height setting (air conditioner)
130 Static pressure setting(air conditioner)
131 Remote controller master / slave setting (air
conditioner / General, DX ventilator)
132 Override Master/Slave setting (air condi-
tioner / General, DX ventilator)
133 Dry contact mode setting (air conditioner /
DX ventilator)
134 Fixed air volume (air conditioner / DX venti-
lator)
135 Zone Type Setting(air conditioner)
135 Zone Number Setting(air conditioner)
136 Emergency heater setting (air conditioner)
137 Function control during group Control set-
ting (air conditioner)
138 External devices of indoor unit setting (air
conditioner)
139 Expand of Temperature Range (air condi-
tioner)
140 Indoor unit address verification (air condi-
tioner / DX ventilator)
141 Static pressure step setting (air conditioner)
142 Guard timer(air conditioner)
143 Fan speed in Cooling thermal off (air condi-
tioner)
144 Primary heater setting(air conditioner)
145 Air conditioner Fan operation interlocked
with ventilation setting (air conditioner)
146 Indoor unit Auto-Start setting (air condi-
tioner / DX ventilator)
147 Occupancy duration time setting(air condi-
tioner)
148 CN_CC setting (air conditioner)
149 CN_EXT setting (air conditioner / DX venti-
lator)
150 Outdoor unit function master setting (air
conditioner / DX ventilator)
151 Fan continuous operation setting (air condi-
tioner)
152 Low Noise Mode Priority setting (air condi-
tioner / DX ventilator)
153 Human detection sensor (air conditioner)
154 Humidity sensing position (air conditioner)
155 ODU cycle priority (air conditioner)
157 Outdoor temp. for heating stages (air condi-
tioner)
158 Estimated energy display (air conditioner)
158 CN_PTC setting (air conditioner)
159 Password initialization (air conditioner / gen-
eral, DX ventilator)
160
Product direction (general ventilator)
161 Express ventilation priority (general , DX
ventilator)
162 Humidification of stand-alone ventilation
mode (general , DX ventilator)
163 Humidification of ventilation with heating
operation (DX ventilator)
164 Ventilation Fan Speed Alignment (general
ventilator)
164 Filter check alarm(general ventilator)
165 GUIDE TO DIFFERENT
MODE OPERATION/OPEN
SOURCE SOFTWARE
165 Different mode operation
165 Open Source Software Notice Information
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 6
9
READ BEFORE OPERATING THE CONTROLLER
8
DESCRIPTION
ENGLISH
READ BEFORE OPERATING THE CONTROLLER
Menu Structure
DESCRIPTION
NEW STANDARD REMOTE CONTROLLER
OK
Operation display
window
On/Off Button
OK Button
Back button
Up/Down/Left/Right
Button
Operation display window
Operation and Settings status display
Back button
When you move to the previous stage from the menu’s set-
ting stage
Up/down/left/right button
When you change the menu’s setting value
OK button
When you save the menu’s setting value
On/Off button
When you turn ON/OFF the air conditioner
Accessories
Menu
Sub function
Energy Saving
Plasma Purification
Fan Auto
Humidification
Electric Heater
Robot Cleaning
Ventilation Kit
Comfort Saving
All Lock
On/Off Lock
Mode Lock
Set temp range lock
Simple Timer
Sleep Timer
Turn-off reservation
Turn-on reservation
Daily Schedule
Schedules & Edit
Exception Day
Timer
Schedule
Lock
Zone Control
..............................................................................39
..............................................................................40
..............................................................................41
..............................................................................42
..............................................................................43
..............................................................................44
..............................................................................45
..............................................................................46
..............................................................................48
..............................................................................48
..............................................................................48
..............................................................................48
..............................................................................50
..............................................................................51
..............................................................................52
..............................................................................53
..............................................................................55
..............................................................................56
..............................................................................58
Override
......................................................................................................................35
......................................................................................................................36
......................................................................................................................47
Fine Dust
Connecting Cable DO Port Remote controller
fixing screws
(4 EA)
Quick Guide User/Installation
Manual
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 8
.........................................................................60
..........................61
..........................61
..........................61
..........................61
..........................63
..........................64
..........................65
................66
................67
..........................68
..........................69
..........................70
..........................73
..........................74
..........................75
..........................75
..........................76
..........................77
..........................78
..........................79
11
READ BEFORE OPERATING THE CONTROLLER
10
READ BEFORE OPERATING THE CONTROLLER
ENGLISH
Energy
Instantaneous Power
Energy Consumption
Energy Saving
Energy Setting
Function
Year-on-year Usage
Weekly Usage
Monthly Usage
Yearly Usage
Temp Setback Timer
Time Limit control
Outdoor Unit Capacity
Target Instantaneous Power
Target Power Consumption
Target Operation Time
Alarm Popup
Usage Data Initialization
Vane Angle Control
Elevation Grill
Robot Cleaning
Auto Dry
Setting
Filter Sign
Change Temperature
Dead Band
Wi-Fi Paring
...............................80
...............................81
...............................82
...............................83
...............................83
...............................84
...............................85
...............................86
....................87
...............................88
.................89
...............................90
...............................92
........................92
...............................94
...............................95
...............................96
...............................97
...............................97
...............................98
.............................101
.............................102
.............................103
.............................104
.............................105
.............................106
.............................107
.............................108
User
Zone Naming
Override Set Time
Home Leave Set Temp
Comfort Cooling
ODU Refrigerant Noise
Reduction
Defrost Mode
Smart Load Control
Low Noise Mode Time
Advanced fan speed “Auto”
Midnight Air Cooling (Ventilator)
Delay Time(Ventilator)
Language
Setpoint type
Human detection mode
Discharge direction
CO2 fan control(Ventilator)
Temperature Unit
Screen Saver Timer
LCD Brightness In Idle
External Device
Date
Time
Summer Time
Password
Schedule Initialization
Theme
Humidity display
System Reboot
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 10
13
READ BEFORE OPERATING THE CONTROLLER
12
READ BEFORE OPERATING THE CONTROLLER
ENGLISH
..........................110
..........................111
..........................112
..........................113
..........................114
..........................125
..........................126
..........................127
..........................128
..........................129
..........................130
..........................131
..........................132
..........................133
..........................134
..........................135
..........................135
..........................136
..........................137
..........................138
..........................139
..........................140
..........................141
..........................142
..........................143
Service
Service Contact
Model Information
RMC Version Information
Error History
Open Source License
Test Run
Central Control Address
ESP
Temperature Sensor(2TH)
Ceiling Height Selection
Static Pressure
RMC Master/Slave
Override Master/Slave
Dry Contact Mode
Fixed Air Volume
Function Control During Group
Control
Fan Speed In Cooling Thermal
off
Installer
Zone Type
Zone Number
Emergency Heater
External devices of indoor unit
Expand of Temperature Range
IDU Address Verification
Static Pressure Step
Guard Timer
Primary Heater
AC Fan Operation Interlocked
With Ventilation
IDU Auto-Start
Occupancy Duration Time
CN_CC
CN_EXT
ODU Function Master
Fan Continuous Operation
Low Noise Mode Priority
Humidity sensing position
Human detection sensor
Notice
• Some functions may not work in some indoor unit products.
Password Initialization
CN_PTC
Product direction(ventilator)
Express ventilation
priority(Ventilator)
Humidification of stand-alone
ventilation mode(Ventilator)
Humidification of ventilation with
heating operation(Ventilator)
Ventilation Fan Speed Align-
ment(Ventilator)
Filter check alarm
(Ventilator)
ODU cycle priority
Outdoor temp. for heating
stages
Estimated energy display
.............................144
.............................145
.............................146
.............................147
.............................148
.............................149
.............................150
.............................151
.............................152
.............................153
.............................154
.............................155
.............................157
.............................158
.............................158
.............................159
.............................160
.............................161
.............................162
.............................163
.............................164
.............................164
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 12
15
DESCRIPTION OF THE OPERATION
14
DESCRIPTION OF THE OPERATION
ENGLISH
Setting screen
Select the category to set using [,(up/down)] button.
Popup screen
The toast message is the message displayed at the bottom of the screen when an operation is
turned On/Off or if a function is set / cancelled.
The popup message is mainly displayed when an error occurred in the product.
In each detail screen of the menu, as in the box in the left figure,
when “<,>” icons are displayed at the same time, you can im-
mediately apply the setting value by pressing [<, >(left/right)]
button.
For the values that can be set in each category, refer to the
detail manual for each function.
In each detail screen of the menu, as in the box in the left figure,
if only “>” icon is displayed, you can move to the detail setting
screen by pressing [>(right) or OK] button.
For the values that can be set in each category, refer to the
detail manual for each function.
< Toast message > < Popup message >
DESCRIPTION OF THE OPERATION
Main screen
In the main screen, press [<, >(left/right)] button to select the category to set, and you can con-
trol by pressing [,(up/down)] button.
Menu screen
In the main screen, press [<, >(left/right)] button to select the menu and press [OK] button to
move to menu screen.
In the menu screen, press [<, >(left/right)] button to select the category to set, and press [OK]
button to move to the detail screen.
< Air conditioner main screen> <Genernal Ventilation main
screen>
<Dx Ventilation main screen>
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 14
16
DESCRIPTION OF THE OPERATION
17
DESCRIPTION OF THE OPERATION
ENGLISH
Interface screen
Select the product (air conditioner or ventilation) to set using [<, >(left/right)] button.
Returning to the screen
In the main screen, after moving to the category by pressing [<, >(left/right)] button, if there is no
remote controller operation, after 10 seconds, it returns to the main screen basic position. (basic
position: indoor temperature display part)
In the screens except the main screen, if there is no remote controller operation for 1 minute, it
moves to the main screen.
When you control the air conditioner and the ventilation product
with one remote controller, the screen is displayed as in the side
figure. You can set the air conditioner by pressing [<(left)] but-
ton and pressing [OK] button to move to the air conditioner
screen.
When you control the air conditioner and the ventilation product
with one remote controller, the screen is displayed as in the side
figure. You can set the ventilation by pressing [>(right)] button
and pressing [OK] button to move to the ventilation screen.
Monitoring / Sub function screen
In the main screen, you can enter the monitoring / sub function screen by pressing [Back] button
and then pressing [<, >(left/right)] button.
- In the monitoring screen, you can check the indoor temperature and outdoor unit monitoring in-
formation.
- In the sub function screen, you can turn on or off the sub function supported by the product.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 16
19
OPERATION SETTING
18
OPERATION SETTING
ENGLISH
Cooling Operation
Cooling operation’s minimum setting temperature is 18°C (16°C).
For some types of the indoor units, the desired temperature can be controlled in the units of 1°C
or 0.5°C.
- Set the desired temperature lower than the indoor temperature.
- Indoor temperature is displayed on the default screen of the remote controller.
- If the setpoint is set higher than the room temperature, then the unit will remain in the cool
mode but will not begin to cool unit the room temperature exceeds the setpoint.
- If you unit is operating in cooling mode and you press the [On/Off] button the cooling operation
will shut off.
NOTE
!
The compressor starts after 3 minutes and the cold wind comes out.
In the cooling operation, you can select the desired temperature in the range of 18°C ~ 30°C
(16°C ~ 30°C).
The favorable temperature difference between the indoor temperature and the outdoor
temperature is 5°C.
For some types of the indoor units, you can select the desired temperature in the range of
16°C ~ 30°C.
What is 3 minute delay function?
After the cooling stops, when the product is started right away, the reason that the cold
wind does not come out is that it is the function to protect the compressor.
The compressor starts after 3 minutes and the cold wind comes out.
OPERATION SETTING
On / Off
Air conditioner and ventilator will be turned on or off.
Press the remote controller’s (On/Off) button.
- If the product is in operation, On/Off button will be illuminated.
If the product is in off, On/Off button backlight will be off.
Operation mode
You can easily control the desired operation mode.
In the main screen, press [<,>(left/right)] button to select the operation mode or home leave or
hold category, and press [,(up/down)] button to set the operation mode.
Some products may not support some operation modes.
Mode Description
Cool Cool the room to the desired temperature.
Dry It removes the moisture with cooling.
Heat Heats the room to the desired room temperature.
AI / Auto
The product automatically provides the appropriate fan speed based on
the temperature of the room.
Fan Fan only operation, no cooling or heating.
Power Cool It provides strong cooling in short time.
Power heating Power heating increases indoor temperature quickly.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 18
21
OPERATION SETTING
20
OPERATION SETTING
ENGLISH
Dry Operation
Dry operation’s initial fan speed is “Low”.
Dry operation does not have a separate desired temperature.
- If you unit is operating in dehumidification mode and you press the [On/Off] button the dehu-
midification operation will shut off.
NOTE
!
If you use it in the rainy season, or when the humidity is high, you can have both the
effective dehumidification and cooling operation at the same time.
Heating Operation
The heating operation’s minimum setting temperature is 16°C.
For some types of the indoor units, the desired temperature can be controlled in the units of 1°C
or 0.5°C.
- Set the desired temperature higher than the indoor temperature.
- Indoor temperature is displayed on the default screen of the remote controller.
- When the desired temperature is set lower than the indoor temperature, warm air doesn't
come out, but for some products, the fan will recirculate room air, or stop altogether.
- If you unit is operating in heating mode and you press the [On/Off] button the heatling operation
will shut off.
NOTE
!
In the heating operation, you can select the desired temperature in the range of 16°C ~ 30°C.
Heating operation is operated only in cooling/heating model. The heating is not operated in
cooling exclusive model.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 20
23
OPERATION SETTING
22
OPERATION SETTING
ENGLISH
AI / Auto operation
Auto operation’s initial desired temperature is 25°C.
The cooling exclusive model’s initial desired temperature is “It’s Fine”.
Cooling/heating model’s desired temperature can be controlled in the units of 1°C or 0.5°C.
For cooling exclusive model, the value can be controlled from “hot” stage to “cold” stage.
- Hot
- A little hot
- It’s fine
- A little cold
- Cold
- If you unit is operating in ai/auto mode and you press the [On/Off] button the ai/auto operation
will shut off.
NOTE
!
If the product is a cooling/heating model, in the auto operation, the desired temperature can
be selected in the range of 18°C ~ 30°C.
If it does not operate as you wish, select another operation mode.
Fan Only Operation
Fan only operation’s initial wind strength is “High”.
Fan only operation does not have a separate desired temperature.
- If you unit is operating in fan only mode and you press the [On/Off] button the the unit will stop.
NOTE
!
It provides the Fan only operation without temperature control, with recirculation of indoor
air.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 22
25
OPERATION SETTING
ENGLISH
24
OPERATION SETTING
Dual setpoint auto operation
The indoor unit automatically manages room temperature with extended heating and cooling set-
ting temperature ranges.
Dual setpoint auto mode can be set in the USER SETTING. This is recommended in North Amer-
ica region.
NOTE
!
• Auto heating function only operates on cooling and heating models.
• Auto heating function doesn’t operate on cooling only models.
• When remote controller has a connection with indoor unit that does not support 'dual
setpoint', thermal operation function of indoor unit is replaced with ON/Off control from the
wired remote, when the user sets target temperatures in the below ranges.
- cooling target temp. range : 87~99 °F (30.5~37.5 °C)
- heating target temp. range : 40~59 °F (4~15.5 °C).
Power Cool Operation
Power cooling quickly lowers the indoor temperature.
Desired temperature: 18°C
Fan speed : Power fan speed
Fan direction: Current fan direction
- During the power cooling, if fan speed or desired temperature is changed, the power cooling is
cleared, and it operates in the cooling operation mode.
- During the power cooling, if you press [On/Off] button, the power cooling operation stops, and
when you press [On/Off] button again, it operates in the cooling operation mode.
Power Heat Operation
Power heating increases indoor temperature quickly.
Desired temperature: 30 °C
Fan speed: Power fan speed
Fan direction: Current fan direction
- If you adjust the fan speed or the desired temperature during power heating, the function is dis-
abled and heating operation mode is activated.
- If you press [On/Off] button during power heating, the function stops and if you press [On/Off]
button again, heating operation mode is activated.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 24
27
TEMPERATURE SETTING
26
OPERATION SETTING - VENTILATOR
ENGLISH
OPERATION SETTING - VENTILATOR
Operation mode
Ventilation (general and direct cooling type ventilation) operation mode supports the following op-
eration modes.
Some products may not support some operation modes.
In the main screen, press [<,>(left/right)] button to select the operation mode category, and press
[∧,∨(up/down)] button to set the operation mode.
The direct cooling type ventilation’s air conditioner operation mode is composed separately
from the ventilation operation mode.
Mode Classification Description
Auto
Ventilation operation
mode – commonly
supported by ventila-
tion products
It measures the ventilation system’s indoor tempera-
ture and the outdoor temperature for the automatic op-
eration in the optimal ventilation mode state.
Heat Exchange
It is the mode of ventilation with both supply/discharge
through the heat exchanger. It is adequate to use in
summer/winter where the indoor/outdoor temperature
difference is big.
Bypass
It is the ventilation where the exhausted air is ventilated
without going through the exchanger. It is adequate to
use in spring/fall or when the indoor contamination is
severe.
Cool
Air conditioner opera-
tion mode – supports
direct cooling type
ventilation
Cools down the room to desired temperature.
Heat It provides warm air to the room.
Auto
The product automatically provides the appropriate fan
speed based on the temperature of the room.
Stop It stops the product’s air conditioner operation.
TEMPERATURE SETTING
Controlling Desired Temperature
You can easily control to the desired temperature.
• In the main screen, press [<,>(left/right)] button to select the desired temperature category,
and press [,(up/down)] button to set the desired temperature.
- In the cooling, heating, and AI/auto mode, the desired temperature control is possible.
Mode Description
Cool
If the desired temperature is higher than the indoor temperature, the
cooling is not performed.
Set the desired temperature lower than the indoor temperature.
You can select in the range of 18°C ~ 30°C (16°C ~ 30°C).
Heat
If the desired temperature is lower than the indoor temperature, the heat-
ing is not performed.
Set the desired temperature higher than the indoor temperature.
You can select in the range of 16°C ~ 30°C.
AI / Auto
For cooling/heating product, you can select in the range of 18°C ~ 30°C.
For cooling exclusive product, you can select Hot, A little hot, Adequate,
A little Cold, and Cold.
NOTE
!
The favorable temperature difference between the indoor temperature and the outdoor
temperature is 5°C.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 26
29
WIND SETTING
28
TEMPERATURE SETTING
ENGLISH
Check Room Temperature
You can check the current indoor temperature.
• In the remote controller’s the main screen, you can check the indoor temperature.
NOTE
!
The temperature distribution in the remote controller installation space is not uniform, so
there can be a little difference between the temperature you actually feel and the remote
controller’s room temperature display
According to Control type setting value
• Single setpoint
Fahrenheit: 52~99 °F
- below 52 °F: display ‘LO’
- over 99 °F: display ‘HI’
Celsius: 10.5~39.5 °C
- below 10.5 °C: display ‘LO’
- over 39.5 °C: display ‘HI’
• Dual setpoints
Fahrenheit: 34~99 °F
- below 34 °F: display ‘LO’
- over 99 °F: display ‘HI’
Celsius: 0.5~39.5 °C
- below 0.5 °C: display ‘LO’
- over 39.5 °C: display ‘HI’
- For indoor temperature below 50 °F (10 °C), the value perceived by the Thermostat(with
cable) is displayed.
• Because of location of Temperature sensing, the real room temperature and the this
displayed value can be different.
WIND SETTING
Fan speed control
From the main screen, press [<,>(left/right)] button to select the fan speed category, and press
[,(up/down)] button to set the fan speed control the desired fan speed.
- It circulates in the order of Slow Low Medium High Power Auto.
For some product some fan speed may not be available.
Fan speed control - ventilation
You can easily control the desired fan speed.
• In the main screen, press [<,>(left/right)] button to select the fan speed category, and press
[,(up/down)] button to set the fan speed.
- It circulates in the order of low high power auto.
The auto Fan can be used only when the air contamination (CO
2
) sensor is installed.
Air flow control
You can easily control the desired air flow
• In the main screen, press [<,>(left/right)] button to select the air flow category, and press
[,(up/down)] button to set the air flow.
- It circulates in the order of Off Up/Down swing Left/Right swing Up/Down/Left/Right
swing Swirl Indirect wind Direct windHuman detection direct windHuman detec-
tion indirect wind.
For some product some air flow settings may not be available.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 28
31
HOLD SETTING
30
HOME LEAVE SETTING
ENGLISH
HOME LEAVE SETTING
Home leave (Unoccupied Mode)
The "Home Leave" function enables proper operation of indoor unit when a space is left for a pe-
riod of time.
This feature can only be used when Control type setting is set to the Dual Set Point Control
mode
NOTE
!
User can not change indoor unit status with wired remote controller while set 'home leave
mode' except for 'home leave mode' release control.
• Home leave mode will be released if indoor unit operation was changed by commands of
other controllers(central controller, drycontact and wireless remote controller).
• When occupied schedule event occurs while operate a home leave mode, home leave
mode will be released and indoor unit status follow the occupied schedule event.
• Indoor unit operation change as below when the home leave mode is released.
- The setpoints and operation mode values are reflected in the control events of the
scheduled events that are currently applied.
- If there are no schedule events, the setpoint shall be applied as last setpoints before the
home leave operation.
- If there are no setpoints before the 'home leave' operation(dehumidification or fan mode),
default values will be applied to the setpoints.
- Default values : dual setpoint auto , heat 60 °F(16 °C), cool 86 °F(30 °C)
HOLD SETTING
Hold
User can use this function when they want to manage indoor unit as home leave control mode
only.
NOTE
!
Can not change indoor unit status with wired remote controller while set ‘hold mode' except
for ‘hold mode' release control.
• Hold mode will be released if indoor unit operation was changed by commands of other
controllers(central controller, drycontact and wireless remote controller).
• A scheduled event is not applied to the indoor unit during a hold mode, even if a scheduled
event is set.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 30
33
EXTERNAL EQUIPMENT CONTROL SETTING
ENGLISH
32
ADDITIONAL OPERATION –VENTILATION
EXTERNAL EQUIPMENT CONTROL SETTING
External equipment control
It is the function to set the contact point output of the external equipment control mode.
• In the main screen, press [<,>(left/right)] button to select the external equipment control cate-
gory, and press [,(up/down)] button to set the contact point output.
Mode Description
On When it is set to “On”, it always performs the contact point output.
Off
When you set it to “Off”, it does not perform the contact point output in
any case.
Auto
When it is set to “auto”, the contact point output is decided according to
the user setting’s external equipment logic setting value.
NOTE
!
Please use the corresponding function when the external equipment is actually connected.
When the external equipment is not set, please maintain “Off” status.
For the detail external equipment control condition setting, refer to the user setting - external
equipment logic setting.
ADDITIONAL OPERATION –VENTILATION
Additional operation
You can change the additional operation of the ventilation product.
• In the main screen, press [<,>(left/right)] button to select the additional operation category, and
press [,(up/down)] button to set the additional operation.
Additional Operation Description
Fast
It ventilates in short period of time.
It is the function to operate the ventilation function more efficiently
through the express setting which is an additional operation of the ventila-
tion product.
Energy saving It performs the energy saving function while ventilating efficiently.
NOTE
!
The general ventilation and the direct cooling type ventilation’s additional operation are the
same.
The ventilation product’s additional functions (air cleaning / heater / humidification / fan auto)
setting methods are the same as the air conditioner.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 32
34
PLASMA PURIFICATION SETTING
35
OVERRIDE CONTROL SETTING
ENGLISH
PLASMA PURIFICATION SETTING
Plasma Purification
It cleans and makes pleasant indoor air.
1. Plasma Purification - single operation
If plasma purification is turned on in operation Off state, plasma purification single operation is
performed.
In case of plasma purification single operation, it operates in fan mode / automatic wind state,
and the wind direction operated before the plasma purification single operation is turned off.
There are 3 ways to end the plasma purification single operation.
1) Input of On/Off button during plasma purification single operation
2) Select plasma purification OFF
3) Change operation mode during plasma purification single operation
2. Plasma purification - additional operation
NOTE
!
• If mode is changed during plasma purification single operation, it is switched to the air
cleaning additional operation.
• Air cleaning operation may not be displayed or performed in some products.
OVERRIDE CONTROL SETTING
Override control
In dual setpoint setting, wired remote controller can manages indoor unit status based on pro-
grammed control events which have occupancy option.
Override control function switches between ‘occupied’ and ‘unoccupied’, and vice-versa.
User can set timer option which can return to original schedule event in override function menu.
OK
NOTE
!
• If there are no 'occupied' schedule event when operate 'override' control, wired remote
controller change indoor unit operation as below default setting value.
- operation mode : Auto
- target temperature : 86 °F(30 °C)(cool), 60 °F(16 °C)(heat)
• If there are no ‘unoccupied' schedule event when operate 'override' control, wired remote
controller change indoor unit operation as 'home leave' mode default value.
- operation mode : Auto
- target temperature: 'home leave' target temperature.
• If wired remote controller received command from other controller, ‘Override’ operation will
be released.
• When schedule event occurs while operating an override mode, override mode will be re-
leased and indoor unit status follow the schedule event.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 34
37
MONITORING SCREEN
ENGLISH
36
MONITORING SCREEN
Fine dusts status
It is the function to monitor dust value measured by the dust sensor mounted inside the air con-
ditioner.
• In the fine dust status screen, you can check fine dust, ultra fine dust, and super ultra fine dust
concentration values.
• The overall index displays the worst dust status value among the three dust status values.
NOTE
!
• The fine dust status may not be displayed in some products.
• Fine dust status can be checked only when the product is in operation.
MONITORING SCREEN
How to enter fine dust status screen
• In the main screen, press [Back] button to move to monitoring/additional functions screen, and
press [<, > (left/right)] button to move to fine dust status screen. (Method 1)
• In the menu screen, press [<, > (left/right)] button to select the fine dust screen category, and
press [OK] button to move to the fine dust status screen. (Method 2)
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 36
38
SUB FUNCTION SETTING
39
SUB FUNCTION SETTING
ENGLISH
Energy Saving Setting
The energy saving cooling function is the function to control the desired temperature during the
cooling operation to improve the comfort of the user and to improve the power saving perform-
ance.
NOTE
!
The energy saving function is an additional function, and it may not be displayed/operated in
some products.
The energy saving function is possible only when the product is in the cooling operation.
SUB FUNCTION SETTING
Sub function entrance and setting method
In the menu screen, press [<,>(left/right)] button to select the sub function category, and press
[OK] button to move to the sub function setting list screen.
In the sub function setting list screen, if you press [<, >(left/right)] button, you can turn on/off the
corresponding sub function. (method 1)
In the main screen, press [Back] button to move to the monitoring/sub function screen, and press
[<,>(left/right)] button to move to the sub function screen. In the sub function screen, select the
sub function category to set, and if you press [OK] button, you can turn on/off the corresponding
function. (method 2)
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 38
41
SUB FUNCTION SETTING
40
SUB FUNCTION SETTING
ENGLISH
Fan Auto Setting
Select fan operation after performing thermal control of indoor units.
If set to 'ON', fan operation keeps on after thermal operation of indoor units.
NOTE
!
The fan auto function is an additional function, and it may not be displayed/operated in some
products.
Plasma Purification Setting
It makes the indoor air clean and pleasant.
NOTE
!
The air cleaning function is an additional function, and it may not be displayed/operated in
some products.
The air cleaning function is possible only when the product is in operation.
If you want air cleaning single operation, set air cleaning in the wind only operation.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 40
43
SUB FUNCTION SETTING
42
SUB FUNCTION SETTING
ENGLISH
Electric Heater Setting
It is the function to reinforce the heating capability by turning on the electric heater during the
heating operation.
NOTE
!
It can be set only in the heating operation.
The heater function is an additional function, and it may not be displayed/operated in some
products.
Humidification setting
It is the function to activate the humidifier installed in the product when the indoor air is dry.
NOTE
!
The humidification function is an additional function, and it may not be displayed/operated in
some products.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 42
45
SUB FUNCTION SETTING
44
SUB FUNCTION SETTING
ENGLISH
Ventilation kit Setting
Function enables operation of an optional ventilation kit with indoor units
NOTE
!
The ventilation kit function is an additional function, and it may not be displayed/operated in
some products.
Robot Cleaning Setting
Robot cleaning function is the function to automatically perform the filter cleaning with the
cleaner in the product when the air conditioner is used for certain period of time.
NOTE
!
It can be set 30 seconds after the operation stopped.
The robot cleaning function is an additional function, and it may not be displayed/operated in
some products.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 44
47
ZONE CONTROL SETTING
ENGLISH
46
SUB FUNCTION SETTING
Comfort Cooling Setting
The comfort cooling is the function to automatically control the cooling strength to maintain the
pleasant feeling without turning off the product after the indoor temperature reached the desired
temperature.
NOTE
!
The comfort cooling function is an additional function, and it may not be displayed/operated in
some products.
The comfort cooling function is only possible when the product is in the cooling operation.
ZONE CONTROL SETTING
Zone Control
A function to control zone with duct type indoor units.
Wired Remote controller can control maximum 8 zones.
OK
NOTE
!
According to installation setting value
• If no function is supported this entry can not function.
• Old type
- Zone control is currently only available to monitor.
• New type(4zone or 8Zone)
- Any number of zones is installed is displayed on the screen can be controlled.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 46
49
TIMER SETTING
ENGLISH
48
LOCK SETTING
LOCK SETTING
How to enter lock setting
• In the menu screen, press [<,>(left/right)] button to select “lock setting” category, and press
[OK] button to move to the lock setting list screen.
• In the lock setting list, if you press [,(up/down)] button, you can turn on/off the correspon-
ding lock function.
Lock setting – all, on/off, mode, temperature range lock
• It is the function to lock the button operation of the remote controller so that children or other
persons cannot use it without permission.
It is the function to limit the desired temperature range that can be set in the wired remote controller.
OK
TIMER SETTING
Timer entrance and setting method
• In the menu screen, press [<,>(left/right)] button to select the timer category, and press [OK]
button to move to the timer setting list screen.
• In the timer setting list screen, press [,(up/down)] button to select the timer to set, and
press [OK] button to move to the detail screen.
• After setting the value, when you press [OK] button, the timer is activated.
• After setting the value, if you press [Back] button, the changed value will not be applied.
OK
Lock Description
All lock It locks all button operation of the remote controller.
On/Off lock It locks the On/Off button operation of the remote controller.
Mode lock It locks the operation mode button operation of the remote controller.
Temperature range
lock
It is the function that can limit the range of the desired temperature that
can be set in the wired remote controller.
- Single: Lower limit : 16~30 °C (60~86 °F)
Upper limit : 16/18~30 °C (60/64~86 °F)
- Dual : Cooling : 50~99 °F (10~37.5 °C)
Heating : 40~90 °F (4~32 °C)
NOTE
!
In the central controller, when the central control temperature range lock is set, the wired
remote controller’s temperature lock setting is cleared.
The temperature change by external equipment is reflected regardless of the remote
controller temperature range lock.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 48
51
TIMER SETTING
ENGLISH
50
TIMER SETTING
Simple timer
You can easily set the timer in the range of 1~7 hours in the units of 1 hour.
OK
NOTE
!
If the product operation is On, the easy timer turns off the operation after the corresponding
time.
If the product operation is Off, the easy timer turns on the operation after the corresponding
time.
If the easy timer operation is turned On/Off before the timer operation, the set timer will be
cleared.
Sleep timer
Sleep timer is the function to operate the air conditioner in sleep mode before going to sleep for
certain hours and stop the operation.
OK
NOTE
!
You can set the sleep timer while the product is in operation.
If the sleep timer operation is turned On before the timer operation, the set timer will be
cleared.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 50
52
TIMER SETTING
53
TIMER SETTING
ENGLISH
Turn-off Reservation
The product is automatically turned Off at the set timer time.
OK
NOTE
!
Even if the Turn-off Reservation operation is turned On/Off after the setting and before the
timer operation, the set timer is not cleared.
Turn-on Reservation
The product is automatically turned On at the set timer time.
OK
NOTE
!
Even if the Turn-on Reseravation operation is turned On/Off after the setting and before the
timer operation, the set timer is not cleared.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 52
55
SCHEDULE SETTING
54
SCHEDULE SETTING
ENGLISH
SCHEDULE SETTING
How to enter schedule
• In the menu screen, press [<,>(left/right)] button so select the schedule category, and press
[OK] button to move to the schedule setting list screen.
• In the schedule setting list screen, press [,(up/down)] button to select the menu to set, and
press [OK] button to move to the detail screen.
OK
Daily Schedule
It is the function that can check the status of the timer (schedule) saved in the remote controller.
• In the schedule list, select the daily schedule status category, and press [OK] button to move to
the detail daily schedule status screen.
• You can use the remote controller’s [<,>(left/right)] button to check the timer information of
other dates.
• You can use the remote controller’s [,(up/down)] button to check the corresponding date’s
other timer information.
• Select the timer information, and press [OK] button to move to the corresponding timer’s edit
screen.
NOTE
!
In the daily schedule status screen, even if the timer (schedule) is set, if the corresponding
date is designated as an exception date, the schedule will not be performed.
Less than 5 schedules per day is recommended.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 54
57
SCHEDULE SETTING
56
SCHEDULE SETTING
ENGLISH
Schedules & Edit
It is the function that can check the status of the timer (schedule) saved in the remote controller.
• In the schedule list, select the daily schedule status category, and press [OK] button to move to
the daily schedule status detail screen.
• You can use the remote controller’s [<,>(left/right)] button to check other date’s timer informa-
tion.
• You can edit the saved schedule’s timer information.
- Select the schedule to edit using [,(up/down)] button, and press [OK] button to move to
the edit screen.
• Select the timer information, and press [OK] button to move to the corresponding timer’s edit
screen.
You can check the set
timer’s operation infor-
mation (operation
On/Off, operation
mode, desired tempera-
ture), timer time, period,
and day of week.
< If schedule is changed > < If schedule is deleted >
Schedules & Edit – Add schedule
Description of each stage in Add schedule
In ‘Stage 1’, it sets the period to perform the timer.
In ‘Stage 2’, it sets the day of week to perform the timer.
- You can select ‘Everyday / Weekend / Weekdays / Individual selection’.
In ‘Stage 3’, it sets the start time for the timer.
In ‘Stage 4’, it sets the timer operation information.
- If ‘Stop’ is selected, you cannot set the mode / temperature / fan speed.
When stages 1~4 are completed, along with the message of ‘schedule is added’, it moves to
View and edit schedule screen.
Stage 1. Period setting Stage 2. Day of week setting
Stage 3. Time setting Stage 4. Operation setting
Add schedule is completed
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 56
59
ENERGY
58
SCHEDULE SETTING
ENGLISH
Exception day
It is the function to automatically stop the operation on the set timer day.
• In the schedule list, select the exception day category, and press [OK] button to move to the
Exception day designation detail screen.
• In the exception day, you can check, and add/change/delete the exception day information
saved in the remote controller.
- To add an exception day, in the Exception day registration detail screen, designate
year/month/day, and press [OK] button to save the Exception day.
- Select the Exception day to edit using [,(up/down)] button, and press [OK] button to move
to the edit screen.
- In the exception day edit screen, you can check, delete/change the corresponding exception
day’s setting contents.
- When you change the exception day information, you need to save it after the change.
ENERGY (air conditioner / DX ventilator)
How to enter energy
• In the menu screen, press [<,>(left/right)] button to select the energy category, and press [OK]
button to move to the energy list.
OK
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 58
61
ENERGY
60
ENERGY
ENGLISH
Instantaneous power check
It is the function that can check the product’s instantaneous power.
There may be some error with the actual instantaneous power, so use it only for reference.
• In the energy list, select the “Instantaneous power” category, and press [OK] button to move
to the detail screen.
• The target and the value of all can be set in the energy setting.
• The usage ratio compared to the target is the value expressed in current/target * 100.
For how to set the energy, refer to the energy setting.
OK
NOTE
!
Instantaneous power: It is the power currently used in the product.
Energy consumption
You can check the energy consumption (operation time, power consumption).
There may be some error with the actual consumption, so use it only for reference.
• In the energy list, select the “energy consumption” category, and press [OK] button to move to
the detail screen.
• In the detail screen, press [<,>(left/right)] button to move to the power consumption and opera-
tion time screen.
OK
<, >
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 60
63
ENERGY
62
ENERGY
ENGLISH
• Operation time unit is time (hr.), and power consumption unit is kWh.
• The power consumption display can be checked when it is connected to the indoor unit that
supports the power consumption information display function.
List
Description
Power consumption Operation time
Year On Year Usage
You can see the power consump-
tion compared to the same month
of the previous year.
You can see the operation time
compared to the same month of
the previous year.
Weekly usage
It displays the daily power con-
sumption of the current month.
It displays the daily operation time
of the current month.
Monthly usage
It displays the weekly power con-
sumption of the current month.
It displays the weekly operation
time of the current month.
Yearly usage
It displays the monthly power con-
sumption of the current year.
It displays the monthly operation
time of the current year.
Energy saving - Temperature Setback Timer
It is the function to return to the desired temperature after the set time after the product opera-
tion for energy saving.
• In the energy list, select “Energy saving” category, and press [OK] button to move to the en-
ergy saving screen.
• In the energy saving list, select “Temperature Setback Timer” category, and press [OK] button
to move to the Temperature Setback Timer setting screen.
• When it is set to On, you can set the time (10 minutes ~ 120 minutes, 10 minutes unit) and the
temperature (18°C ~ 30°C), and after the setting, when you press [OK] button, the set value is
saved.
• When the desired temperature setback timer setting is set to “On”, after the set time, the de-
sired temperature is recovered to the set temperature.
OK
OK
NOTE
!
When it is set at the same time with the remote controller desired temperature range lock or
the central control temperature range lock, it may not return to the desired temperature.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 62
65
ENERGY
64
ENERGY
ENGLISH
Energy saving - Time Limit Control
It is the function to stop the product operation after the set time after starting the product opera-
tion for the energy saving.
• In the energy saving list, select “time limit control” category, and press [OK] button to move to
the time limit control setting screen.
• In the detail screen, you can select “On/Off” to turn on and off the time limit control function.
When it is set to On, you can set the time (30 minutes ~ 540 minutes, 30 minutes unit), and
after the setting, if you press [OK] button, the set value is saved.
If you do not press [OK] button but press [Back] button, it moves to the list screen without sav-
ing the set value.
• If the time limit control is set to “On”, the operation stops after the set time.
OK
OK
NOTE
!
If it is set at the same time with the remote controller operation lock, the time limit control
will not be performed.
Energy setting - outdoor unit capacity setting
It is the function that can set the outdoor unit capacity.
• In the energy list, select “energy setting” category, and press [OK] button to move to the en-
ergy setting screen.
• In the energy setting list, select “outdoor unit capacity setting” category, and press [OK] button
to move to the outdoor unit capacity setting screen.
• In the detail screen, you can select “On/Off” to set the outdoor unit capacity. If it is set to On,
you can set the outdoor unit capacity (minimum 1kW), and after the setting, if you press [OK]
button, the set value is saved. If you do not press [OK] button but press “Back’ button, it
moves to the list screen without saving the set value.
• If the capacity setting is set to “On”, in the Instantaneous power screen, it is displayed as “all”
capacity.
• For the outdoor unit capacity, refer to the label of the outdoor unit product.
- For Single product and Multi product, the first 3 digits of the model name is the outdoor unit
capacity.
ex) For ABC1019…, it is 10.1kW
- For Multi-V product, the first 2 digits of the model name < 0.75 is the outdoor unit capacity.
ex) For ABCD101.…, it is 10 * 0.75 = 7.5kW
• For TMS users, refer to the all capacity displayed on TMS.
OK
OK
NOTE
!
According to the user input, there may be difference to the actual product capacity.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 64
67
ENERGY
66
ENERGY
ENGLISH
Energy setting - target instantaneous power setting
It is the function that can set the Instantaneous power’s target value.
You can set the target value to find the power consumption status.
• In the energy setting list, select “target Instantaneous power” category, and press [OK] button
to move to the target Instantaneous power setting screen.
• In the detail screen, you can select “On/Off” to set the target Instantaneous power.
If it is set to On, you can set the target Instantaneous power (minimum 1kW), and after the
setting, if you press [OK] button, the set value is saved.
- If the outdoor unit capacity is set, the maximum value is the outdoor unit capacity
- If the outdoor unit capacity is not set, the maximum value is 9999kW
If you do not press [OK] button but press “Back’ button, it moves to the list screen without
saving the set value.
• When the target Instantaneous power setting is set to “On”, in the Instantaneous power
screen, it is displayed as “all” capacity.
OK
OK
Energy setting - target power consumption
It is the function to set the target power consumption per hour.
• In the energy setting list, select “target power consumption” setting category, and press [OK]
button to move to the target power consumption setting screen.
• In the detail screen, you can select “On/Off” to set the target power consumption.
When it is set to On, you can set the target power consumption (minimum 1kWh, maximum
100kWh), and after the setting, if you press [OK] button, the set value is saved.
If you do not press [OK] button but press “Back’ button, it moves to the list screen without
saving the set value.
• If the target power consumption setting is set to “On”, it is displayed as the energy
consumption’s power consumption target value.
- Daily target consumption: Weekly usage’s daily target
- Weekly target consumption: Monthly usage’s weekly target (daily target * 7)
- Monthly target consumption: Yearly usage’s monthly target (daily target * 31)
OK
OK
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 66
68
ENERGY
69
ENERGY
ENGLISH
Energy setting - target operation time
It is the function that can set the Instantaneous power’s target value.
You can find the power consumption status by setting the target value.
• In the energy setting list, select “target operation time” category, and press [OK] button to
move to the target operation time setting screen.
• In the detail screen, you can select “On/Off” to set the target operation time.
When it is set to On, you can set the target operation time (minimum 1hr. and maximum 24hr.),
and after the setting, if you press [OK] button, the set value is saved.
If you do not press [OK] button but press “Back’ button, it moves to the list screen without
saving the set value.
• If the target operation time setting is set to “On”, it is displayed as the energy consumption’s
operation time target value.
- Daily target : Weekly usage’s daily target
- Weekly target : Monthly usage’s weekly target (daily target * 7)
- Monthly target : Yearly usage’s monthly target (daily target * 31)
OK
OK
Energy setting - Alarm Popup Setting
It is the function to set whether to use the target power consumption and the target operation
time notice popup window.
• In the energy setting list, select “target operation time” category, and press [OK] button to
move to the target operation time setting screen.
• In the notice popup list, select “target power consumption notice or target operation time no-
tice” category, and press [OK] button to move to the detail setting screen.
• You can set the notice popup as “daily”, “weekly”, “monthly”.
After the setting, if you press [OK] button, the setting is saved and moves to the previous
screen.
• When the target power consumption notice is set to “On, daily”
If the daily target power consumption’s 80%, 90%, 95%, and 100% power is used a day, the
popup screen appears.
• When the target operation time notice is set to “On, daily”
When the product is operated at the daily target operation time’s 80%, 90%, 95%, and 100%,
the popup screen appears.
OK
OK
NOTE
!
The popup message appears once every hour.
OK
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 68
71
FUNCTION SETTING
70
ENERGY
ENGLISH
Energy setting – Usage data initialization
It is the function to initialize all of the power consumption and operation time information.
• In the energy setting list, select “consumption data initialization” category, and press [OK] but-
ton to move to the consumption data initialization setting screen.
• In the initialization popup screen, if you press “check” button, all previously saved power con-
sumption and operation time are deleted.
OK
OK
OK
FUNCTION SETTING
How to enter function setting
To enter the menu displayed at the bottom, you need to enter the function setting menu as fol-
lows.
• In the menu screen, press [<,>(left/right)] button to select the setting category, and press [OK]
button to move to the setting list.
• In the setting list, select the function setting category, and press [OK] button to move to the
function setting list.
OK
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 70
73
FUNCTION SETTING
72
FUNCTION SETTING
ENGLISH
Function Setting Vane angle control setting
You can control the wind blowing angle.
- In the function setting list screen, press [,(up/down)] button to select the vane angle control
category, and press [OK] button to move to the up/down vane angle detail screen.
• In the detail screen, press [,(up/down)] button to select “individual control, overall control,
standard”.
• Use [<,>(left/right)] button to select the vane.
- The selected vane is moving. Check the moving vane.
• Press [,(up/down)] button to select the desired wind angle, and press [OK] button to save
the setting.
- The wind angle’s setting range can be changed to 5 stages or 6 stages according to the prod-
uct.
If you do not press [OK] button, the selected wind angle will not be reflected.
OK
NOTE
!
For some product types, there are products with only 1 or 2 vanes.
Control Description
Each It sets the vane angle individually.
All It sets the vane angle of all the vanes of the product at once.
Standard It sets the vane angle to the factory initialization state.
Menu Description
Vane angle control setting
You can control the wind blowing angle.
Elevation grill setting
It is the function to operate the Elevation grill for the indoor unit filter cleaning.
Robot cleaning setting
Robot cleaning function is the function to automatically perform the filter
cleaning with the cleaner of the product when the air conditioner is used for
certain time period. It sets the manual or automatic operation of the robot
cleaning. You can set it 30 seconds after the stopping of the operation.
Auto dry setting
Auto dry function is the function to remove mold and moisture by dry-
ing the inside of the indoor unit after the cooling operation and when
the product is turned off.
Filter sign check and ini-
tialization
When it becomes the time for the indoor unit filter cleaning, the filter
cleaning display appears, and it is the function to remove the display.
Change Temperature
setting
Change Temperature is the function to set the temperature for the au-
tomatic conversion between cooling and heating according to the
temperature in AI operation mode.
Dead Band
When heating and cooling desired temperatures have been changed,
the set value will maintain a difference between the heating and cool-
ing desired temperature.
Wi-Fi pairing
It is the function to perform the pairing function of the Wi-Fi module
connected to the indoor.
Zone Name setting Zone name settings allow you to select zone name.
Override set time setting When timed override is used, the set time will be a default value.
Home leave set temper-
ature setting
When customer operate as home leave mode, this setting tempera-
ture value will be applied.
Comfort cooling setting
It is the function to set the outdoor unit Comfort saving operation
stage value.
ODU Refrigerant Noise
Reduction setting
It is the function to set the outdoor unit’s refrigerant noise reduction
function.
Defrost Mode setting It is the function to set the outdoor unit’s defrost mode operation.
Smart load control
setting
It is the function to set the outdoor unit’s smart load control stage value.
(Smart load control is the function to calculate the necessary performance
with the indoor and outdoor air temperature and humidity and operate.)
Low noise mode time
setting
It is the function to set the start and end time of the outdoor unit’s
low noise mode operation.
Advanced fan speed “Auto”
It is the function to set the indoor unit’s fan auto by temperature.
Delay time setting (ex-
clusive for ventilation)
It is the function to set the ventilation operation to start after the delay
time.
Midnight air cooling
(ventilation interface)
It is the function to discharge indoor air and supply cool outdoor air
into the indoor during summer nights to save energy.
Human detection mode It is the function to set the operation of human detection mode.
Discharge direction
This is a function to set the usage of the upper and lower vanes when
operating the product.
CO2 fan control
A function that controls the fan when the product is turned ON/OFF,
based on the CO2 concentration in the ventilation product.
1,MFL69312302,영영 2018. 11. 19. 영영 11:18 Page 72
75
FUNCTION SETTING
74
FUNCTION SETTING
ENGLISH
Elevation grill setting
It is the function to operate the Elevation grill for the indoor unit filter cleaning.
- While the product operation is stopped, if you use [<,>(left/right)] button to select the setting
value, the grill operation status changes.
Value Description
Up Raises the Elevation grill toward the product
Stop Stops the movement of the Elevation grill
Down Lowers the Elevation grill toward the floor
NOTE
!
The Elevation grill setting function may not work in some products.
Robot cleaning setting
Robot cleaning function is the function to perform the automatic filter cleaning with the cleaner
of the product when the conditioner is used for certain period of time. It sets the manual or auto-
matic operation of the robot cleaning.
- It can be set 30 seconds after the operation stop.
• You can use [<,>(left/right)] button to set the following setting values as follows.
Auto dry setting
Auto dry function is the function to remove mold and moisture by drying inside the indoor unit
after the cooling operation and when the product is turned off.
• You can use [<,>(left/right)] button to set the following setting values as follows.
Value Description
Auto
It automatically performs the robot cleaning when the accumulated in-
door unit operation time passes 30 hours
Manual It manually performs the robot cleaning.
NOTE
!
The robot cleaning setting function may not work in some products.
Value Description
Use Use auto dry function
Not Use Not use auto dry function
NOTE
!
Auto dry setting function may not work in some products.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 74
77
FUNCTION SETTING
76
FUNCTION SETTING
ENGLISH
Filter sign check and initialization
When it becomes the time for the indoor unit filter cleaning, the filter cleaning message appears,
and it is the function to remove the message.
• In the function setting list, select the Filter sign check and initialization category, and press [OK]
button to display the detail screen.
- When it becomes time to the filter clean, “Filter cleaning or replacement is required.” message
is displayed. Enter the Filter sign check and initialization detail screen.
- If the product has the function to display the time remaining until the filter cleaning, even if the
filter cleaning message is not displayed, you can enter the Filter sign check and initialization.
- If there is a remaining time display function, when you enter the Filter sign detail screen, you
can see the consumption and the remaining time.
OK
NOTE
!
• Some products have a Filter Time Remaining function that can be accessed with Filter Sign
check.
• Dirty filters will increase the cost to cool or heat the conditioned space.
• The filter check message is cleared after certain time without a separate clearing.
Filter sign Description
Good Usage time is 70% or less
Normal Usage time is 71~80%
Caution Usage time is 81~99%
Bad Usage time is 100%
Change temperature setting
Change Temperature is the function to set the automatic Change Temperature between cooling
and heating operation according to the temperature in AI operation mode.
• In the function setting list, select the Change Temperature category, and press [OK] button to
move to the detail screen.
It is the function that can be used only in cooling/heating product.
Example of using Change Temperature
Condition
1) Mode: AI mode
2) temperature: 22°C
3) Change Temperature: 3°C Change Temperature 3°C difference
In case of the above conditions, it operates as in the graph.
OK
NOTE
!
The Change Temperature setting function may not work in some products.
Value
1~7°C(Default : 2°C)
Temp()
25
22
19
ڸڸ
ڹ
ڸ : Cooling operation start
ڹ : Heating operation start
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 76
79
FUNCTION SETTING
78
FUNCTION SETTING
ENGLISH
Wi-Fi pairing setting
It is the function to perform the pairing function of the Wi-Fi module connected to the indoor unit.
• In the function setting list, select the Wi-Fi pairing category, and press [OK] button to move to
the detail screen.
- After selecting “Apply”, if you press [OK] button, the Wi-Fi pairing popup window is created,
select “check” and press [OK] button to request the Wi-Fi pairing.
OK
NOTE
!
The Wi-Fi setting function may not work in some products.
Dead Band
Dead Band function is used with a dual setpoint mode.
When heating and cooling desired temperatures have been changed, the set value will maintain a
difference between the heating and cooling desired temperature.
• In the function setting list, select the dead band category, and press [OK] button to move to the
detail screen.
OK
NOTE
!
Dead Band function only can use in dual setpoint mode.
• When changing the desired cooling temperature, in case of that the difference with the
heating temperature becomes lesser than its minimal value of difference, it lowers the
desired heating temperature automatically.
• When changing the desired heating temperature, in case of that the difference with the
heating temperature becomes lesser than its minimal value of difference, it raises the
desired cooling temperature automatically.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 78
81
FUNCTION SETTING
ENGLISH
80
FUNCTION SETTING
Zone Name setting
Zone name settings allow you to select zone name.
OK
NOTE
!
Zone name setting function may not work in some indoor unit products.
OK
Override Set Time Setting
Override Set Time function can only be used in Dual Setpoint Control mode.
When timed override is used, the set time will be a default value.
OK
NOTE
!
Override Set Time function can only be used in a dual setpoint control mode.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 80
83
FUNCTION SETTING
ENGLISH
82
FUNCTION SETTING
Home Leave Set Temperature Setting
Home Leave Set Temperature function is used in Dual Setpoint Control mode.
When customer operate as home leave mode, this setting temperature value will be applied.
OK
NOTE
!
Home Leave Set Temperature function can only be used in a dual setpoint control mode.
Comfort cooling setting
It is the function to set the outdoor unit Comfort saving operation value.
• You can set the following values using [<,>(left/right)] button.
ODU Refrigerant Noise Reduction setting
It is the function to set the outdoor unit’s refrigerant noise reduction function.
• You can use [<,>(left/right)] button to set the following setting values as follows.
Value
Step 1
Step 2
Step 3
NOTE
!
The Comfort cooling function does not work in the group control.
Comfort cooling setting function is only available in some products.
NOTE
!
The ODU Refrigerant Noise Reduction function can be set only when the installer setting’s
outdoor unit function M/S setting is set to “Master”.
ODU Refrigerant Noise Reduction function is only available in some products.
Value Description
Step 0 Not use
Step 1 Outdoor unit noise mode 1
Step 2 Outdoor unit noise mode 2
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 82
85
FUNCTION SETTING
84
FUNCTION SETTING
ENGLISH
Defrost mode setting
Change the outdoor unit’s defrost mode operation.
• Select value using [<,>(left/right)] button.
Value
Step 0 Not use
Step 1 Forced snow removal
Step 2 Quick defrost
Step 3 Forced snow removal + quick defrost
NOTE
!
The Defrost mode setting function can be set only when the installer setting’s outdoor unit
function M/S setting is set to “Master”.
Defrost mode setting function is only available in some products.
Smart load control(SLC) setting
Change the outdoor unit’s Smart Load Control stage value.
(Smart load control is the function to calculate the indoor air temperature, outdoor air tempera-
ture, and humidity to operate effectivly.)
• In the function setting list, select the Smart load control category, and press [OK] button to
move to the detail screen.
- When SLC is Operating, on the expanded screen’s monitoring information, ‘In Smart load con-
trol’ is displayed.
Value
Off Step 0
On
Step 1
Step 2
Step 3
Step 4
NOTE
!
Smart load control function can be set only when the installer setting’s outdoor unit function
M/S setting is set to “Master”.
Smart load control function is only available in some products.
Step4 settings may not be available on some indoor unit products.
OK
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 84
87
FUNCTION SETTING
86
FUNCTION SETTING
ENGLISH
Low noise mode time setting
It is the function to set the start and end time of the outdoor unit’s low noise mode operation.
• In the function setting list, select the Low Noise Mode Time category, and press [OK] button to
move to the detail screen.
- After setting the start time and the end time, press [OK] button to move to the upper level
list.
- If the start time and the current time are the same, it enters the outdoor unit low noise opera-
tion mode, and in the monitoring screen, ‘in outdoor unit low noise operation mode’ message
is displayed.
- If the end time and the current time are the same, the outdoor unit low noise operation mode
is cleared.
NOTE
!
Low noise mode time setting function can be set only when the installer setting’s outdoor
unit function M/S setting is set to “Master”.
Low noise mode time setting function is only available in some products.
OK
CAUTION
If the function is not used, please set it to Off.
When you enter the low noise operation, the cooling capacity may be degraded.
!
Advanced fan speed “Auto” setting
It is the function to set the indoor unit’s temperature based auto fan usage.
It is the function to automatically change the fan speed according to the difference between the
indoor temperature and the desired temperature.
• You can set the following setting values using [<,>(left/right)] button.
Value Description
Set Do not change the fan speed automatically
Clear Change the fan speed automatically
NOTE
!
Advanced fan speed “Auto” setting function is only available in some products.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 86
89
FUNCTION SETTING
88
FUNCTION SETTING
ENGLISH
Delay time (exclusive for ventilation)
It is the function to set the ventilation operation to start after the delay time.
• In the function setting list, select the delay time category, and press [OK] button to move to the
detail screen.
- After setting the minute, press [OK] button to move to the upper level list.
Value
0 ~ 60 Minutes
OK
Midnight air cooling (ventilation interface)
It is the function to discharge indoor air and supply cool outdoor air into the indoor during sum-
mer nights to save energy.
• In the function setting list, if you select midnight outdoor air cooling category and press [OK]
button, it moves to the detail screen.
- When you set the start and end time and press [OK] button, it saves and moves to the upper
level list.
NOTE
!
Whether to run the midnight air cooling is decided only when both air conditioner and
ventilation are stopped.
• Even if it is the set midnight air cooling time, it enters the midnight air cooling only when
the outdoor temperature conditions is met.
• During the midnight air cooling operation, “in midnight outdoor air cooling” message is
displayed on the monitoring screen.
• Midnight air cooling function may not work in some products.
OK
CAUTION
. If you do not use the function, please set it as off.
!
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 88
91
FUNCTION SETTING
ENGLISH
90
FUNCTION SETTING
Human detection mode setting
It is the function that enables energy saving through the human detection power saving operation
and wind direction setting.
In the function setting list, select human detection operation mode category and press [OK] but-
ton to move to the lower level setting list.
After selecting human detection power saving mode category, if you press [OK] button, it moves
to the detail screen.
You can select OFF ← → On/Off Power saving ← → Temperature power saving for mode value.
You can set the time value when you select On/Off power saving or Temperature power saving.
OK
After selecting human detection wind direction category, you can set the following setting values
using [<,> (left/right)] button.
NOTE
!
Human detection operation setting function may not work in some products.
Value Description
OFF Do not use human detection wind direction control
Direct Human detection direct wind operation
Indirect Human detection indirect wind operation
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 90
92
FUNCTION SETTING
93
USER SETTING
ENGLISH
USER SETTING
How to enter user setting
To enter the menu displayed at the bottom, you need to enter the user setting menu as follows.
• Select the setting category, and press [OK] button to move to the setting list.
• Select the user setting category, and press [OK] button to move to the user setting list.
User Setting
• You can set the product user functions.
• Some functions may not be available in some product types.
OK
Menu Description
Language setting Set the language to be displayed on the remote controller.
Setpoint Type Setting It is the function to set GUI type on the remote controller.
Temperature unit setting Set the temperature unit displayed on the remote controller.
Screen saver timer setting Adjust the screen Off time of the remote controller.
LCD brightness in idle setting Adjust the remote controller’s screen brightness.
External device setting Set the name of external equipment and equipment logic setting
Date setting Set the date displayed on the remote controller.
Time setting Set the time displayed on the remote controller.
Summer time setting Set the summer time in the remote controller.
Password setting
Set the password to prevent unauthorized change to remote controller settings.
Schedule initialization Initialize all timer settings in the remote controller.
Theme setting Set the theme of the remote controller screen.
Humidity display
It is the function to decide whether to display humidity on the main
screen and additional information screen.
System reboot Restart the remote controller.
Discharge direction
This is a function to set the usage of the upper and lower vanes when operating the product.
You can set the following setting values using [<,>(left/right)] button.
CO2 Fan Control(general ventilator)
A function that controls the fan when the product is turned ON/OFF, based on the CO2 concen-
tration in the ventilation product.
1.
After selecting “CO2 fan control” in the Function settings list, press the [OK] button to go to the detail
screen.
2. After selecting “Fan control during operation on” or “Fan control during operation off” in the "
CO2 Fan Control" list, you can set the following values using [<,>(left/right)] button.
Discharge
direction
Concurrency (whole)
Top
Bottom
NOTE
!
Discharge direction setting function may not be available on some products.
OK
Condition 1 Condition 2
Operation on
Off
Low
Periodic
Operation off
Off
Periodic
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 92
95
USER SETTING
ENGLISH
94
USER SETTING
Setpoint Type Setting
It is the function to set GUI type on the remote controller.
* Dual setpoint type is a function that makes it possible to set the cooling and heating target tem-
perature simultaneously. It is recommended for customers accustomed to using North Ameri-
can thermostats.
We recommend that you use it only in the region (North America).
If select dual setpoint option, target temperature ranges will be expanded and activated over-
ride, home leave, hold mode and occupancy information based schedule.
<Dual setpoint> <Single setpoint>
Language setting
Set the language to be displayed on the remote controller.
• In the user setting list, select the language category, and press [OK] button to move to the de-
tail screen.
• After the setting, if you press [OK] button, the setting is saved and moves to the previous
screen.
Language
한국어
English Français
Deutsche Italiano Español
Русский Polski Português
中文
Čeština
OK
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 94
97
USER SETTING
96
USER SETTING
ENGLISH
Screen saver timer setting
Adjust the screen Off time of the remote controller.
• Select the following setting values using [<,>(left/right)] button.
LCD brightness in idle setting
Adjust the remote controller’s screen brightness.
• Select the following setting values using [<,>(left/right)] button.
Value
0%
10%
(default)
20% 30%
CAUTION
Selecting brighter stand by screen will decrease LCD lifespan.
!
Value
15sec 30sec (default) 1min
CAUTION
Selecting longer stand by screen will decrease LCD lifespan.
!
Temperature unit setting
Set the temperature unit displayed on the remote controller.
• In the user setting list, select the temperature unit setting category, and press [OK] button to
move to the detail screen.
Value
Celsius
1°C
0.5°C
Fahrenheit
OK
CAUTION
The temperature unit function may not work or work differently in some products.
You cannot set the temperature unit in the slave wired remote controller.
!
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 96
99
USER SETTING
98
USER SETTING
ENGLISH
External device setting
Set the name of external equipment and equipment logic setting
• In the user setting list, select the external device setting category, and press [OK] button to
move to the detail screen.
External device use
• In the external device setting list, select “External device use” category, and press [OK] button
to move to the external device use setting screen.
- If external device use setting value is use, you can see the control unit of external device in
main screen.
OK
Value
Not use Use
External device types
It is the function to set the name of the External device attached to the remote controller.
• You can set the following setting values using [<,>(left/right)] button.
Value
Motor Lighting Fan Heater Pump Others
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 98
101
USER SETTING
100
USER SETTING
ENGLISH
On condition / Off condition
It is the function to set to use the information managed by the wired remote controller as the
contact point control condition to widen the usage of the contact point (Digital Output) installed in
the remote controller.
• In the external device setting list, select the On/Off condition setting category, and press [OK]
button to move to the detail screen.
• The External device operates as the operation set in the conditions 1~3.
• If the External device is set to auto while both ON condition and OFF condition are not set, con-
tact point OFF is output.
• If the ON condition and OFF condition are the same, it is finally processed as OFF condition.
OK
Condition 1 Condition 2 Condition 3 Condition 4
None Deactivate - Deactivate
Aircon
On -
External device name On
External device name Off
Cool mode -
Heat mode -
Fan mode -
Dry mode -
Auto mode -
Current Temp. 1°C~ 39.5°C
Over
Under
Occupied - -
Unoccupied - -
Date setting
Set the date displayed on the remote controller.
• In the user setting list, select the date category, and press [OK] button to move to the detail
screen.
• After the setting, if you press [OK] button, the setting is saved and moves to the previous
screen.
OK
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 100
103
USER SETTING
102
USER SETTING
ENGLISH
Time setting
Set the time displayed on the remote controller.
• In the user setting list, select the time category, and press [OK] button to move to the detail
screen.
• After the setting, if you press [OK] button, the setting is saved and moves to the previous
screen.
OK
Summer time setting
Set the daylight savings time dates in the remote controller.
• In the user setting list, select the summer time setting category, and press [OK] button to
move to the detail screen.
- Summer time: The system to advance the time by 1 hour from the spring when the day is
longer and return back in the fall when the day gets shorter.
- When it becomes AM 02:00 on the DST start date, the current time changes to AM 03:00,
and when it becomes AM 02:00 of the DST end date, the current time changes to AM 01:00.
OK
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 102
105
USER SETTING
104
USER SETTING
ENGLISH
Password setting
Set the password to prevent unauthorized change to remote controller settings.
• Select the user password setting category, and press [OK] button to move to the detail screen.
- If the password is set, when you enter “menu – setting”, you need to input password to
enter the setting list.
- When you forgot the password, you can initialize the password using the installer setting’s
“password initialization”.
The initialized password is “0000”.
OK
Schedule initialization
Initialize all timer settings in the remote controller.
• In the user setting list, select the schedule initialization setting category, and press [OK] button
to move to the detail screen.
- Press the check button to initialize the sleep/simple timer, on/off timer, schedule and excep-
tion date in the remote controller.
OK
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 104
107
USER SETTING
106
USER SETTING
ENGLISH
Theme setting
Set the theme of the remote controller screen.
• Select either white or black using [<,>(left/right)] button.
Humidity display
It is the function to decide whether to display humidity on the main screen and additional infor-
mation screen.
You can use [<, > (left/right)] button to set the setting values (On or Off).
NOTE
!
If humidity display is `ON`, the displayed humidity is different according to the humidity
detection location setting (installer setting).
• Remote controller: remote controller humidity display.
• Indoor unit: If it receives indoor unit humidity, it displays the indoor unit humidity, and if it
does not receive indoor unit humidity, it does not display humidity.
Setting value
ON Display humidity.
OFF Do not display humidity.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 106
109
SERVICE SETTING
ENGLISH
108
USER SETTING
System restart
Restart the remote controller.
• In the user setting list, select the system restart setting category, and press [OK] button to
move to the detail screen.
- In the detail screen, when you press [OK] button, a popup message is displayed, press the
check button, to restart the system.
- For forced reset, press down [On/Off + Back] button for 5 seconds to restart the system.
OK
SERVICE SETTING
How to enter service setting
To enter the menu displayed at the bottom, you need to enter the service setting menu as fol-
lows.
• In the menu screen, press [<,>(left/right)] button to select the setting category, and press [OK]
button to move to the setting list.
• In the setting list, select the service setting category, and press [OK] button to move to the
service setting list.
Service setting
• You can set the product service functions.
• Some functions may not be displayed/operated in some product types.
OK
Menu Description
Service contact
Check and input the service center phone number that you can call
when there is service issue.
Model Information
Check the indoor/outdoor product group and capacity information to
which the remote controller is connected.
RMC Version Information Check the remote controller model name and software version.
Error History View the connected indoor unit’s error history.
Open Source License View the remote controller’s open source license.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 108
111
SERVICE SETTING
110
SERVICE SETTING
ENGLISH
Service contact
Check and input the service center phone number that you can call when there is service issue.
• In the service setting list, select the service contact point and press [OK] button to move to the
detail screen.
• While “edit” button is selected, press [OK] button to move to the edit screen, change it, and
press [OK] button to change the service contact point.
OK
OK
Model information
Check the indoor/outdoor product group and capacity information to which the remote controller
is connected.
• In the service setting list, select the indoor/outdoor model information category, and press [OK]
button to move to the detail screen.
• Indoor unit capacity
- 1kWh = 1kBtu * 0.29307
kWh is the result calculated based on Btu, There may be a small difference between calcu-
lated and actual capacity.
Ex) If the indoor unit capacity is 18kBtu, it is displayed as 5kWh.
OK
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 110
113
SERVICE SETTING
112
SERVICE SETTING
ENGLISH
RMC Version Information
Check the indoor/outdoor product group and capacity information to which the remote controller
is connected.
• In the service setting list, select the remote controller version information check category, and
press [OK] button to move to the detail screen.
OK
Error history
View the connected indoor unit’s error history.
• In the service setting list, select ‘check error history’ category, and press [OK] button to move
to the detail screen.
- You can view up to 20 error instances sorted by date occurred.
OK
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 112
115
INSTALLATION
114
SERVICE SETTING
ENGLISH
Open source license
View the remote controller’s open source license.
• In the service setting list, select the open source license category, and press [OK] button to
move to the detail screen.
OK
INSTALLATION
Installation of Remote Controller
• After fixing the remote controller installation plate on the desired location, fix it firmly with the
provided screws.
- If the installation plate is not flat on the surface, it may result in the controller being twisted
and cause a defect.
- If there is a mounting box, install the remote controller installation plate using the fixings holes
which suit, as in the below diagrams.
- Do not leave a gap with the wall or product loose after the installation.
• The wired remote controller cable can be installed in 3 directions. Install to the suitable
direction according to the installation environment.
- Installation direction: Rear entry, top side, right side
- When you install the remote controller cable at the top side and right side, remove the remote
controller cable guide hole before the installation.
Use a long nose pliers to remove the guide hole.
• After removing the hole, trim the cut surface neatly.
• After fixing the remote controller top side on the installation plate attached to the wall as in the
following figure, press the bottom side to combine with the installation plate.
- Do not leave a gap in the top, bottom, left, and right side of the remote controller and the in-
stallation plate after combining them.
- Before combining with the installation plate, arrange the cables to avoid interference with the
circuit parts.
<Order of Combining>
ڹ Top side guide groove
ڹ Top side guide groove
ڸRear cable entry
ںRight side guide
groove
ںRight side guide
groove
Wall Wall
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 114
117
INSTALLATION
116
INSTALLATION
ENGLISH
• When you remove the remote controller from the installation plate, insert a small flat head
screwdriver into the bottom side separation hole and turn clockwise to separate the remote
controller.
- There are 2 separation holes at the bottom part. Slowly separate one by one.
- Be careful not to damage the internal parts during the removal.
<Order of Separation>
• Use the connection cables to connect the indoor unit with the remote controller.
• For the following cases, separately purchase and use the cables suitable for the situation.
- Do not install the cable over 50 m. (It may cause communication issues.)
- If the distance between the wired remote controller and the indoor unit is 10 m or more : 10
m extension cable (model name: PZCWRC1)
- If you control several indoor unit products with one wired remote controller : Group control
cable (model name: PZCWRCG3)
Wall Side
Please check if connector is normally connected.
Connecting cable
Indoor
Unit side
OK
DC 12 V Red
Signal Yellow
GND Black
NOTE
!
During the wired remote controller installation, do not bury it in the wall. (It may cause
temperature sensor failure.)
Do not install the cable over 50 m. (It may cause communication defect.)
When you install the extension cable, carefully check the direction of the connectors on the
remote controller side and the product side before the installation.
Specification of extension cable: AWG 24, 3 conductor or above.
Group control
• It connects and controls 2 or more air conditioner indoor units to one wired remote controller.
Connect using the group control cable.
Group control cable (PZCWRCG3): Connect to indoor unit’s wired remote controller connector
Extension cable (PZCWRC1): Connect to No. cable and slave indoor unit’s wired remote
controller connector
While No. cable is connected, connect No. cable.
After checking the existence of the event communication in the product manual, change
master/slave of the remote controller.
For details, refer to ‘remote controller master/slave’ contents.
• Change master/slave of the indoor unit.
- For ceiling cassette and duct product group, change the setting with the indoor unit PCB
switch.
RED(12V)
YELLOW(SIG)
BLACK(GND)
YELLOW(SIG)
BLACK(GND)
YELLOW(SIG)
BLACK(GND)
OK
Indoor unit Main PCB
Indoor unit 1
Indoor unit 2 Indoor unit 3
Master Slave Slave
1
2
NOTE
!
• Connect only GND and signal cable to the indoor unit set as slave. (If power cable is also
connected, it may cause loss of communication)
• Inquiries related to the purchase of the cable shall be directed to the specialized company
and the service center.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 116
119
INSTALLATION METHOD TO USE EXTERNAL DEVICE
118
INSTALLATION
ENGLISH
- For the details on the wireless remote controller master/slave setting changes, refer to the
wireless remote controller manual.
- After completing the master/slave setting in the indoor unit product, turn Off the power of the
indoor unit product, and turn On the power after 1 minute.
NOTE
!
• During the group control, set only 1 indoor unit as master.
• During the group control, some functions other than the basic operation setting, fan speed
Low/Med/High, remote controller lock setting, and time setting may be limited.
• During the individual control, if the master indoor unit Dip switch is set to slave, malfunction
may occur.
INSTALLATION METHOD TO USE EXTERNAL
DEVICE
Cable connection method to use external device
1) Wired remote controller-cable connection method.
- In the wired remote controller, connect the part marked in the following figure (J02C, DO-
Port) to the cable.
- According to the installation environment, there are 3 directions (Rear entry, top side, and
right side) for the installation.
2) Cable extension connection method
- Among the cables connected to the wired remote controller, cut the remaining connectors
on the other side, and then extend and connect the cables
- Extension cable specification: 24~26AWG.
CAUTION
For the External device connection, use the cable insulated with sheath for the extension connec-
tion.
Before combining with the installation plate, arrange the cables to avoid interference with the in-
ternal parts.
!
RMC
DO-Port
2 (GND_Black)
3 (DC 12 V_Red)
Field connection
30cm
• Output specification
- Voltage : DC 11~12V
- Current : 5mA
Remote
controller
product
composition
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 118
121
INSTALLER SETTING
120
AIR CONDITIONER AND VENTILATION INTERFACE
ENGLISH
AIR CONDITIONER AND VENTILATION IN-
TERFACE
• It controls using the wired remote controller at a place where the air conditioner indoor unit and
the ventilation product are connected and installed at the same time.
- When the power is applied, the remote controller recognizes the product and operates nor-
mally.
The wiring method is the same as the air conditioner user manual. (Refer to the remote con-
troller manual group control page contents)
Ventilation product means general ventilation product and direct cooling type ventilation prod-
uct.
Independent operation Interfaced operation
General
ventilation
WIRED
REMOTE
CONTROLLER
General
ventilation
OK
WIRED
REMOTE
CONTROLLER
General
ventilation
Air conditioner
indoor unit
OK
Direct
ventilation
WIRED
REMOTE
CONTROLLER
General
ventilation
OK
WIRED
REMOTE
CONTROLLER
General
ventilation
Air conditioner
indoor unit
OK
[general ventilation
independent operation]
[General ventilation interfaced operation]
[Direct ventilation interfaced operation]
[Direct ventilation
independent operation]
INSTALLER SETTING
How to enter installer setting
• In the menu screen, press [<,>(left/right)] button to select the setting category, and press
[(up)] button for 3 seconds to enter the password input screen for the installer setting.
• Input the password and press [OK] button to move to the installer setting list.
Installer setting password
Main screen menu setting service RMC version information SW Version
Example) SW version : 1.00.1 a
In the above case, the password is 1001.
CAUTION
The installer setting mode is the mode to set the remote controller’s detail function. If the in-
staller setting mode is incorrectly set, it may cause product failure, user’s injury, or property dam-
age. It must be set by the installation specialist with the installation license, and if it is installed or
changed without installation license, all problems caused will be the responsibility of the installer,
and may void the LG warrenty.
!
OK OK
NOTE
!
Some categories of the installer setting menu may not be available depending on the
product function or the menu name may be different.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 120
123
INSTALLER SETTING
122
INSTALLER SETTING
ENGLISH
Installer setting – air conditioner
• You can set the product user functions.
• Some functions may not be displayed/operated in some product types.
Menu Description
Test run setting
It is the function to set the trial operation at the initial product installa-
tion.
Central control address
Setting
It is the function to set the central control address of the indoor unit
during the central controller connection.
ESP setting
It is the function to set the wind amount value corresponding to each
wind amount for easy installation.
Temperature sensor setting
It is the function to select the temperature sensor that will decide the
indoor temperature.
Ceiling height setting
It is the function to control the wind amount stage according to the
ceiling height for the ceiling type products.
Static pressure setting
The fixed pressure setting can be set only in the duct products.
It cannot be set in other products.
RMC master/slave setting It is the function to set group control or 2-remote controller control.
Override master/slave setting
The operation master / slave selection function is to avoid other mode
operations, and it is the function to prevent the selection of the oppo-
site mode of the indoor unit set as master by the indoor units set as
slaves.
Dry contact mode setting
Dry contact function is the function that can be used only when the
dry contact devices is separately purchased and installed.
Fixed air volume
It is the function to apply different fan speeds automatically for each
thermal control status.
Zone Type Setting
It is possible to setup zone new type or old one of the product which
is available to install the damper controller.
Zone Number Setting
Zone Number is to set the number of installed zones. It's possible to
control only in zone new type.
Emergency Heater setting
It is the function to set whether to use emergency heater control func-
tion and the usage environment.
Func. control during grp.
Control setting
It is the function to set common functions or some functions to be
controlled by the master indoor unit standard during the group control.
Option Kit – Plasma / Heater /
Humidification / Elevation grill
/ Ventilation / Refrigerant leak-
age detection sensor
It is the function to set whether to mount option unit (Plasma / Humid-
ification / Heater / Ventilation / Elevation grill / Aux Heater / Refrigerant
leakage detection sensor) when it is additionally installed or removed
after the mass production.
Expand of Temperature Range
This function is used for select setting temperature range option.
Indoor unit address verifica-
tion
This function allows you to check the address of the indoor unit desig-
nated by the outdoor unit.
Static pressure step setting
This is the function that static pressure of the product is divided in 11
steps for setting.
Menu Description
Guard timer
It is a function that sets the minimum running time of outdoor unit
cycle mode when switching from cooling mode to heating mode and
vice versa during Auto Operation mode.
Fan speed in Cooling thermal
off
It is a function that sets the indoor unit fan movement, in cooling
mode, when thermal is off.
Primary heater setting
It is the function to set the heater usage to have higher priority over
the outdoor unit cycle during the indoor unit heating operation.
Air conditioner Fan operation
interlocked with ventilation
setting
It is the function to set whether to operate the air conditioner fan dur-
ing the interface operation of the air conditioner and the ventilation
product.
Indoor unit Auto-Start
setting
It is a function that sets whether to restore the indoor unit operation
by resuming the previous power-on state or as power-off state in the
power failure compensation.
Occupancy duration time
setting
It is the function to set the occupied decision maintaining time among
the occupied sensor values.
CN_CC setting
It is the function to set whether to install (use) Dry Contact.
(It is not a function for Dry Contact installation, but it is a function to
set the usage of the indoor unit’s CN_CC port.)
CN_EXT setting
It is the function to set the indoor unit’s Dry Contact Port to control ex-
ternal input and output according to DI/DO set by the customer. (It is
the function to decide the usage of the contact point port (CN_EXT)
mounted in the indoor unit PCB.)
ODU function master setting It is the function to set the outdoor unit’s function Master / Slave.
Fan continuous operation
setting
It is the function to set the indoor unit’s continued Fan function usage.
It is the function to maximize the cooling/heating efficiency by the out-
door unit operating the indoor unit fan operation longer than the previ-
ous operation method.
Low noise mode priority
setting
It is the function to set the main agent of the low noise mode control.
(It is the function to set only one of the outdoor unit / remote con-
troller can control the low noise operation.)
Human detection sensor set-
ting
It is the function to set whether to install human detection sensor and
operation standard value.
Humidity sensing position It is the function to set the location to detect humidity.
ODU cycle priority This function can select standby mode or priority cooling.
Outdoor temp. for heating
stages
This function can select outdoor temperature values for use reference
point of heater and heating mode operation.
Estimated energy display This function can set to display energy data which ODU estimated.
CN_PTC setting This is a function to set PTC Port of indoor unit.
Password initialization
It is the function to initialize (0000) the password when you forgot the
password set in the remote controller.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 122
125
INSTALLER SETTING
124
INSTALLER SETTING
ENGLISH
Installer setting - ventilator
• You can set the product user functions.
• Some functions may not be displayed/operated in some product types.
Menu Applied products Description
Test run setting DX(Direct Exchanger) Type It is the function to set the trial operation at the initial product installation.
Central control address Setting General
It is the function to set the central control address of the indoor unit during
the central controller connection.
Air supply ESP
General/DX Type
It is the function to set the fan speed value corresponding to the air supply
side fan speed.
Air discharge ESP
It is the function to set the fan speed value corresponding to the air dis-
charge side fan speed.
Temperature sensor setting DX Type
It is the function to select the temperature sensor that will decide the indoor
temperature.
Product direction General It is the function to set the ventilation indoor unit’s installation direction.
Express ventilation priority
General/DX Type
It is the function to set the priority of the air supply and discharge during the
express ventilation operation.
RMC master/slave setting It is the function to set group control or 2-remote controller control.
Override master/slave setting DX Type
The operation master / slave selection function is to avoid other mode oper-
ations, and it is the function to prevent the selection of the opposite mode
of the indoor unit set as master by the indoor units set as slaves.
Dry contact mode setting DX Type
Dry contact function is the function that can be used only when the dry con-
tact devices is separately purchased and installed.
Fixed fan speed setting DX Type
It is the function to set the indoor unit’s fan speed option to variable or fixed.
Hum. Of Stand-alone Vent.
Mode
General/DX Type
It is the function to set whether to use the humidification function in the di-
rect cooling type ventilation’s ventilation single operation.
Hum. Of Vent. With Heating
Oper.
DX Type
It is the function to set the direct cooling type ventilation’s heating humidifi-
cation function as auto or manual.
Vent. Fan Speed Alignment General
It is the function to increase/decrease ventilation’s standard fan speed from
the current status according to the field environment.
Indoor unit address verification DX Type
This function allows you to check the address of the indoor unit designated
by the outdoor unit.
Indoor unit Auto-Start setting DX Type
It is a function that sets whether to restore the indoor unit operation by re-
suming the previous power-on state or as power-off state in the power fail-
ure compensation.
CN_EXT setting DX Type
It is the function to set the indoor unit’s Dry Contact Port to control external input
and output according to DI/DO set by the customer. (It is the function to decide the
usage of the contact point port (CN_EXT) mounted in the indoor unit PCB.)
ODU function master setting DX Type It is the function to set the outdoor unit’s function Master / Slave.
Low noise mode priority setting DX Type
It is the function to set the main agent of the low noise mode control. (It is
the function to set only one of the outdoor unit / remote controller can con-
trol the low noise operation.)
Filter check alarm General This function sets the filter check alarm of the ventilation product.
Test run setting (air conditioner / DX ventilator)
After product installation, the Test run must be performed. For Test run related details, refer to
the product manual.
• In the installer setting list, select the Test run setting category, and press [OK] button to move
to the detail screen.
- You can select ‘cooling Test run / heating Test run’
- During the Test run, if you start the following functions, the Test run stops.
Operation mode, desired temperature, fan speed, wind direction, start/stop
OK
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 124
127
INSTALLER SETTING
126
INSTALLER SETTING
ENGLISH
Central control address setting (air conditioner / general, DX
ventilator)
It is the function to set the central control address of the indoor unit to allow communication with
a central controller,
• In the installer setting list, select the central control address setting category, and press [OK]
button to move to the detail screen.
- Select a hex value between 00 and FF.
Value 1: group address setting / value 2: indoor unit address setting
OK
ESP setting (air conditioner / general, DX ventilator)
It is the function to set the fan speed value corresponding to each fan speed for easy installation.
• In the installer setting list, select the ESP setting category, and press [OK] button to move to
the detail screen.
OK
NOTE
!
If ESP is incorrectly set, the air conditioner may malfunction.
This function must be set by the installation specialist that holds an installation license.
For ventilation products, separate ESP values are used for the supply and exhaust fans.
NOTE
!
Be especially careful not to switch ESP values corresponding to each fan speed.
Engineering manuals have ESP setting tables that reference air flow and corresponding
value setting to achieve the flow.
The ESP values that can be set may be different for each product and capacity.
Product ESP fan speed value
Air conditioner
Slow
0 ~ 255
Low
Med
High
Power
Ventilation
Low
High
Power
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 126
129
INSTALLER SETTING
128
INSTALLER SETTING
ENGLISH
Temperature sensor(2TH) setting (air conditioner / DX ventilator)
It is the function to select the temperature sensor to decide the indoor temperature.
• You can set the following setting values using [<,>(left/right)] button.
• 2TH function’s operation characteristics may be different for each product.
Temperature sensor location Description
Remote controller
Operate the system with wired remote controller’s temperature
sensor
Indoor Unit Operate the system with indoor unit’s temperature sensor
2TH
Cool
Compare the temperatures of the indoor unit and the wired re-
mote controller and operate with the higher temperature
(There are system operated with lower temperature)
Heat
Compare the temperatures of the indoor unit and the wired re-
mote controller and operate with the lower temperature
Ceiling height setting (air conditioner)
It is the function to control the fan speed stage according to the ceiling height in the ceiling type
product.
• You can set the following setting values using [<,>(left/right)] button.
Ceiling height Description
Low Fan speed operates one step slower than the default value.
Standard Operates at the default fan speed
High
Fan speed operates one step faster than the default value.
Very high
Fan speed operates two steps faster than the default value.
NOTE
!
When group control is enabled some functions are limited depending on product type.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 128
131
INSTALLER SETTING
130
INSTALLER SETTING
ENGLISH
Static pressure setting(air conditioner)
Static pressure setting can be set only in the duct products. (It cannot be set in other products.)
• You can set the following setting values using [<,>(left/right)] button.
• 2TH function’s operation characteristics may be different for each product.
Static pressure
Description
Variable / Fixed ESP default value
Variable high static pressure V-H Variable High static pressure(High)
Fixed high static pressure
F-H Fixed High static pressure(High)
Variable low static pressure
V-L Variable Low static pressure(Low)
Fixed low static pressure
F-L Fixed Low static pressure(Low)
Remote controller master / slave setting
(air conditioner / General, DX ventilator)
This function sets configuration for the master/slave setting through the remote controller.
• Change setting values using [<,>(left/right)] button.
• 2TH function’s operation characteristics may be different for each product.
M/S Description
Master (default)
Using group control, the indoor units are operated based on the re-
mote controller.
Slave
Using group control, all remote controllers except 1 master remote
controller are set as slaves.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 130
133
INSTALLER SETTING
132
INSTALLER SETTING
ENGLISH
Override Master/Slave setting (air conditioner / General, DX
ventilator)
The operation master / slave selection function is to avoid other mode operations, and it is the
function to prevent the selection of opposite mode of the indoor unit master by the indoor units
set as slaves.
• Change setting values using [<,>(left/right)] button.
M/S Description
Master Using group control, this master sets the mode of slave IDU’s.
Slave
For the indoor unit set as slave, it can only select the some operation
mode of the master indoor unit cycle.
Ex) Master is in cooling cycle, Slave can select cooling, dehumidifica-
tion, auto, and wind only
Master is in heating cycle, Slave can select auto, heating, and wind
only
NOTE
!
Override M/S setting function is only available in some products.
Dry contact mode setting (air conditioner / DX ventilator)
Dry contact function is the function that can be used only when the dry contact devices is sepa-
rately purchased and installed.
• Change setting values using [<,>(left/right)] button.
Value
Auto
manual
NOTE
!
For dry contact mode related detail functions, refer to the individual dry contact manual.
What is dry contact?
It means the contact point signal input when the hotel card key, human body detection
sensor, etc. are interfacing with the air conditioner.
Added system functionality by using external inputs (dry contacts and wet contacts).
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 132
135
INSTALLER SETTING
134
INSTALLER SETTING
ENGLISH
Fixed air volume (air conditioner / DX ventilator)
It is the function to apply different fan speeds automatically for each thermal control status.
• You can set the following setting values using [<,>(left/right)] button.
Value Comp on Comp off
Variable Set fan speed Low
Fixed Set fan speed Set fan speed
Zone Type Setting(air conditioner)
This function is only available on some products.
This function select a type of zone control type which indoor unit support as 'new type' or 'old
type'.
Zone Number Setting(air conditioner)
This function is only available on some products.
Zone Number is to set the number of installed zones. It's possible to control only in zone new
type.
Value
Old
New(4 Zone)
New(8 Zone)
Value
New(4 zone) : 2~4
New(8 zone) : 2~8
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 134
137
INSTALLER SETTING
136
INSTALLER SETTING
ENGLISH
Emergency heater setting (air conditioner)
Enable the emergency heater control function and the usage environment.
• In the installer setting list, select the emergency heater setting category, and press [OK] button
to move to the detail screen.
- In case of an error, it sets whether the emergency heater can be used / outdoor temperature
standard heater operation usage setting and temperature step value setting / and during the
emergency heater operation, whether to use the indoor unit fan operation.
OK
Value
Outdoor temperature standard heater
operation
Fan operation in emergency
control
Not use - -
Use
Emergency heater Step 0 ~ 3
On/Off
Extended emer-
gency heater
Step 0 ~ 15
NOTE
!
This function setting must be carried out by a certified-technician.
Function control during group Control setting (air conditioner)
This function enables the control of the common functions or some functions based on the mas-
ter indoor unit during the group control.
• Change setting values using [<,>(left/right)] button.
Value Description
Not use Common function,
Use
Use expanded function which
is based on master indoor unit
NOTE
!
Common functions and some indoor unit master standard setting shall be set only during
the group control with the same type indoor units.
During the group control with different indoor unit types, set it as ‘000’ to use the existing
group control method.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 136
139
INSTALLER SETTING
138
INSTALLER SETTING
ENGLISH
External devices of indoor unit setting (air conditioner)
At the Code field, select when air cleaner/heater/humidifier/elevation grill/ventilation KIT/Aux
Heater/refrigerant leakage detection sensor are newly installed to the indoor unit or when an in-
stalled KIT is removed.
• You can set the following setting values using [<,>(left/right)] button.
Function Value
Plasma purification
Not install / Install
Heater
Humidifier
Elevation grill
Ventilation Kit
Aux Heater
Refrigerant leakage detection sensor
Expand of Temperature Range (air conditioner)
This function using in dual setpoint control mode.
This function is used for select setting temperature range option.
NOTE
!
When the set values are changed, the items below will be initialized.
- Target temperature (default: Cooling: 86 °F(30 °C)/ Heating: 60 °F(16 °C))
'home leave' temperature (default: Cooling: 86 °F(30 °C)/ Heating: 60 °F(16 °C))
In case of the setting expanded temperature range (set), please note that the setting of the
wired remote controller can be altered under below circumstances.
- In case of cooling at 30~37.5 °C(64~99 °F), it is changed to cooling at 86 °F(30 °C).
- In case of heating at 4~15.5 °C(40~86 °F), it is changed to heating at 60 °F(16 °C).
- If set on dual setpoint, it is changed to the current operation mode(cooling or heating) of
the indoor unit.
Situation where changes in the setting occur
a. Operates the Auto address work and pipe search in situations such as product installment
and service.
b. Occurrence of errors and deactivation.
c. Command generated by the central control, outdoor unit, Dry contact, Remote controller,
indoor unit switch.
Value
Clear : 60~86 °F / 16~30 °C (default)
Set : 40~99 °F / 4~37.5 °C
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 138
141
INSTALLER SETTING
ENGLISH
140
INSTALLER SETTING
Indoor unit address verification (air conditioner / DX ventilator)
This function allows you to check the address of the indoor unit designated by the outdoor unit.
• In the installer setting list, select the indoor unit address check category, and press [OK] button
to move to the detail screen.
OK
Static pressure step setting (air conditioner)
It is the function to subdivide and set the product’s Static pressure to 11 stages.
• Change setting values using [<,>(left/right)] button.
Value
Step 0 ~ Step 11
NOTE
!
If Static pressure step setting is used, the Static pressure setting is not used.
For the Static pressure step value for each stage, refer to the indoor unit product manual
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 140
143
INSTALLER SETTING
142
INSTALLER SETTING
ENGLISH
Guard timer(air conditioner)
It is a function that sets the minimum running time of outdoor unit cycle mode when switching
from cooling mode to heating mode and vice versa during Auto Operation mode.
Under the condition of cooling/heating switching, it switches between cooling and heating mode
after operation during the time scheduled in the Guard timer.
Fan speed in Cooling thermal off (air conditioner)
Indoor unit fan, in cooling mode, during thermal off condition.
• Select value using [<,>(left/right)] button.
Step Value
0 0 minute
1 15 minutes
2 30 minutes
3 45 minutes
4 60 minutes
Value
Low Fan speed low
Off Fan off
Setting fan speed setting value
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 142
145
INSTALLER SETTING
144
INSTALLER SETTING
ENGLISH
Primary heater setting(air conditioner)
It is the function to set the air conditioner fan operation if the ventilation is operated while the air
conditioner operation is stopped when the air conditioner and the ventilation are installed to inter-
face with each other.
• You can set the following setting values using [<,>(left/right)] button.
Value Description
Not use During the heating, heater is set to be used as secondary
Use During the heating, heater is set to be used as main
Air conditioner Fan operation interlocked with ventilation setting
(air conditioner)
It is the function to set the air conditioner fan operation if the ventilation is operated while the air
conditioner operation is stopped when the air conditioner and the ventilation are installed to inter-
face with each other.
• You can set the following setting values using [<,>(left/right)] button.
- When the air conditioner operation is Off, if the ventilation product is in operation, the air condi-
tioner fan shall be operated, and when the fan is in operation, dust may fall, so it is the function
to set the air conditioner fan operation status in case of ventilation interface through the setting.
Value Description
Off The air conditioner indoor unit Fan is Off during the ventilation interface
On
The air conditioner indoor unit operates in very weak wind during the ventila-
tion interface
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 144
147
INSTALLER SETTING
146
INSTALLER SETTING
ENGLISH
Indoor unit Auto-Start setting (air conditioner / DX ventilator)
It is a function that sets whether to restore the indoor unit operation by resuming the previous
power-on state or as power-off state in the power failure compensation.
• You can set the following setting values using [<,>(left/right)] button.
Value Description
Use Use indoor unit auto restart
Not use Not use indoor unit auto restart
Occupancy duration time setting(air conditioner)
It is a function that sets the light-on/occupancy duration after motion is detected when installing
an occupancy sensor.
• You can set the following setting values using [<,>(left/right)] button.
Value
0 Minute
10 Minutes
30 Minutes
60 Minutes
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 146
149
INSTALLER SETTING
148
INSTALLER SETTING
ENGLISH
CN_CC setting (air conditioner)
It is the function to set the usage of the indoor unit’s CN_CC port.
• Select CN_CC setting category, and press [OK] button to move to the detail screen.
OK
Value Description
DC auto install
(default)
When power is applied to the product, indoor unit when the contact
point is on in Dry Contact installed state recognizes Dry Contact installa-
tion
DC manual not install Do not use (install) Dry Contact
DC manual install Use (install) Dry Contact
Programmable DI/DO Use as Programmable DI/DO (Simple On/Off)
NOTE
!
CN_CC is the device connected to the indoor unit to recognize and control the external
contact point.
CN_EXT setting (air conditioner / DX ventilator)
It is the function to set to control the external input and output according to DI/DO set by the cus-
tomer using the indoor unit’s Dry Contact Port. (It is the function to decide the usage of the con-
tact point port (CN_EXT) mounted in the indoor unit PCB.)
• In the installer setting list, select CN_EXT setting category, and press [OK] button to move to
the detail screen.
OK
Value Description
Not use
(default)
Use installer code No. 41 setting value (simple Dry Contact setting
value)
Simple operation
control
Simple operation On/Off
Single emergency stop Indoor unit single emergency stop
Occupied / Unoccupied Occupied / Unoccupied
All emergency stop
Indoor unit all emergency stop
It can be set only when there is indoor unit emergency stop
function.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 148
151
INSTALLER SETTING
150
INSTALLER SETTING
ENGLISH
Outdoor unit function master setting (air conditioner / DX ven-
tilator)
It is the function to set the outdoor unit’s function Master / Slave.
• You can set the following setting values using [<,>(left/right)] button.
Value Description
Slave
Cannot enter the Smart load control function setting
Cannot enter the low noise operation time setting
Cannot enter the refrigerant noise reduction setting
Cannot enter the defrost mode setting
Master
Smart load control function setting is possible
Low noise operation time setting is possible
Refrigerant noise reduction setting is possible
Low noise operation control main agent setting is possible
Defrost mode setting is possible
CAUTION
When you change the outdoor unit function master setting from master to slave, check the op-
eration status of the outdoor unit function (outdoor unit low noise operation, smart load control)
and make sure to stop the outdoor unit function before the change.
!
Fan continuous operation setting (air conditioner)
It is the function to set the indoor unit’s continued fan function usage. (It is the function to maxi-
mize the cooling/heating efficiency by the outdoor unit operating the indoor unit fan operation
longer than the previous operation method.)
• You can set the following setting values using [<,>(left/right)] button.
Value Description
Clear Do not use continued fan usage
Set Use continued fan usage
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 150
153
INSTALLER SETTING
152
INSTALLER SETTING
ENGLISH
Low Noise Mode Priority setting (air conditioner / DX ventilator)
It is the function to set the low noise mode control main agent. (It is the function to set that only
one of the outdoor unit / remote controller can control the low noise operation.)
• You can set the following setting values using [<,>(left/right)] button.
Value Description
RMC
Ignore the outdoor unit PCB’s low noise operation Switch Setting value
- Function setting – remote controller low noise operation time menu de-
activation
ODU(default)
It is controlled in the outdoor unit itself according to the outdoor unit
PCB’s low noise operation Switch Setting value
- Function setting – remote controller low noise operation time menu de-
activation
Human detection sensor (air conditioner)
It is the function to set whether to install human detection sensor and operation standard value.
• In the installer setting list, after selecting human detection sensor setting category, if you press
[OK] button, it moves to the detail screen.
• You can set the following setting values for each category using [<,> (left/right)] button.
Value Description
Installation status Not installed, basic installation, 90º rotation installation
Detection result sending cycle 5 s, 30 s, 1 min., 3 min.
Sensitivity setting Standard, low sensitivity, high sensitivity
Temperature control option
Step 0 : Keeps the product running and uses the tem-
perature power saving function.
Step 1 : The operation of indoor units is stopped by
using the temperature power saving function.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 152
155
INSTALLER SETTING
154
INSTALLER SETTING
ENGLISH
Humidity sensing position (air conditioner)
It is the function to set the location to detect humidity.
You can use [<, > (left/right)] button to set the following setting values.
Value Description
Remote controller (default value) Humidity sensor of the remote controller itself
Indoor unit Humidity received from indoor unit
ODU cycle priority (air conditioner)
This function can set cycle priority of outdoor unit.
Multi V Heat Pump system does not support mixed mode therefore wired remote controller can
not show opposite operation mode for select option while ODU operate cooling or heating cycle.
Set this function user can select opposite operation mode with wired remote controller and in-
door units enter to ‘standby’ status or outdoor unit can support cooling first and operate heating
with heater.
OK
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 154
157
INSTALLER SETTING
ENGLISH
156
INSTALLER SETTING
Option Description
Not use
Does not support opposite cycle operation using wired remote controller
- When ODU operate as cooling cycle selectable operation modes with
wired remote controller are cool, auto, dehumidification and fan.
- When ODU operate as heating cycle selectable operation modes with
wired remote controller are heat, auto and fan
Standby
When user set opposite operation mode using wired remote controller in-
door unit stop thermal operation and fan.
Cool
Cooling cycle has a priority.
When user change operation mode of specific indoor unit to cooling on
heating cycle, outdoor unit change cycle to cooling and Indoor unit keep
heating operation using heater.
h Please set emergency heater and aux heater function before using this
option
h When user select cooling option, additional setting menu will be activated.
The additional timer setting menu is for setting minimum cooling operation period.
Once outdoor unit change over to cooling by cooling priority, outdoor unit can change over to
heating after set time.
Setting value Cooling operation time
Step 0 45 min.(default)
Step 1 30 min.
Step 2 60 min.
Step 3 90 min.
Step 4 120 min.
Outdoor temp. for heating stages (air conditioner)
It is a function that sets outdoor temperature values for two stage heating.
if user set outdoor temperature T1 and T2, Indoor unit will select heating stage between Indoor
unit operation and heater operation.
OK
T1 Value T2 Value
-23 ~ 16 °C (-10 ~ 60 °F) -23 ~ 51 °C (-10 ~ 130 °F)
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 156
159
INSTALLER SETTING
ENGLISH
158
INSTALLER SETTING
Estimated energy display (air conditioner)
This function can set to display energy data which outdoor unit estimated power consumption
data without wattmeter.
CN_PTC setting (air conditioner)
This is a function to set PTC Port of indoor unit.
Password initialization (air conditioner / general, DX ventilator)
It is the function to initialize (0000) when you forgot the password set in the remote controller.
• In the installer setting list, select the password initialization setting category, and press [OK]
button to move to the detail screen.
• When you press “initialization” button, a popup screen appears, and when you press “check”
button, password initialization starts, and the user password is changed to 0000.
OK
Setting value Description
Use Display energy consumption data which outdoor unit estimated
Not Use Not display energy consumption data which outdoor unit estimated
Setting value Description
Normal Auxiliary heating interlock deactivated
Special Auxiliary heating interlock activated
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 158
Product direction (general ventilator)
It is the function to set the direction of the ventilation product.
• Select value using [<,>(left/right)] button.
Value
Normal Reverse
INSTALLER SETTING
160
ENGLISH
INSTALLER SETTING
161
Express ventilation priority (general , DX ventilator)
It is the function to set the priority of the air supply and air discharge during the express ventila-
tion operation.
• Select value using [<,>(left/right)] button.
Value
Priority in air supply Priority in air discharge
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 160
Humidification of stand-alone ventilation mode (general , DX
ventilator)
It is the function to set whether to use the humidification function during the ventilation product
single operation.
• Select value using [<,>(left/right)] button.
Value
Not use Use
ENGLISH
INSTALLER SETTING
162
INSTALLER SETTING
163
Humidification of ventilation with heating operation
(DX ventilator)
It is the function to set the heating humidification function of the direct ventilation to be auto-
matic or manual.
• Select value using [<,>(left/right)] button.
Value
Not use Use
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 162
Ventilation Fan Speed Alignment (general ventilator)
It is the function to change the standard fan speed of the ventilation product.
• Select value using [<,>(left/right)] button.
Filter check alarm(general ventilator)
This function sets the filter check alarm of the ventilation product.
• Select value using [<,>(left/right)] button.
Value
Default value 10% increase 10% decrease 20% decrease
Value
Step 0 - 5
ENGLISH
INSTALLER SETTING
164
GUIDE TO DIFFERENT MODE OPERATION/OPEN SOURCE SOFTWARE
165
GUIDE TO DIFFERENT MODE
OPERATION/OPEN SOURCE SOFTWARE
Different mode operation
Different mode operation is the case when the indoor units’ operation modes are different when
multiple indoor units are installed to one outdoor unit. (Different mode operation doesn’t happen
in the cooling exclusive model.)
• Example of different mode operation
- When one indoor unit is operated in heat while several indoor units one outdoor unit are oper-
ated in cooling, the heating operation is not performed.
- With one outdoor unit, while several indoor units are in heat mode, if one indoor unit requests
in cooling or dehumidification, the operation is not performed.
Open Source Software Notice Information
To obtain the source code under GPL, LGPL, MPL, and other open source licenses, that is con-
tained in this product, please visit http://opensource.lge.com. In addition to the source code, all
referred license terms, warranty disclaimers and copyright notices are available for download. LG
Electronics will also provide open source code to you on CD-ROM for a charge covering the cost
of performing such distribution (such as the cost of media, shipping, and handling) upon email re-
quest to opensource@lge.com. This offer is valid for a period of three years after our last ship-
ment of this product. This offer is valid to anyone in receipt of this information.
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 164
1,MFL69312302,영영 2018. 11. 19. 영영 11:19 Page 990
79


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for LG PREMTB100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of LG PREMTB100 in the language / languages: English as an attachment in your email.

The manual is 16,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of LG PREMTB100

LG PREMTB100 User Manual - German - 84 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info