possible as alternative to automatic compensation. Operating
displays depend on the setting and current operation in the
flash display and camera viewfinder (where / warnings
also appear if above or below the flash range). With a manually
set (
m
) or automatically controlled (
A
) shutter speed of
1/250s or slower: Without pre-flash: Normal, TTL controlled
fill-in flash exposure; with pre-flash: guide number controlled
fill-in flash exposure according to the calculated subject
distance and based on the TTL pre-flash metered result.
Strobe flash mode (multiple flashes fired during an exposure)
Automatic adjustment of exposure time with system-compa-
tible and appropriately equipped flash units.
Flash metering cells Silicon photo diodes in bottom of came-
ra protected from stray light.
Film speed range for TTL flash exposure metering
For SCA controlled metering: ISO 12/12° to ISO 3,200/36°
For test flash metering: ISO 25/15° to ISO 400/27°
Displays in flash mode Readiness status: Flashing of con-
stant illumination of flash symbol in viewfinder and rear panel
LCDs. Success check: Over- and underexposure indicated by
or signal in camera viewfinder for approx. 4s after exposure.
Flash exposure compensation ±3
1
/
3
EV in
1
/
3
EV steps on
SCA 3002 standard flash units or on the SCA 3501/3502M3
adapter with TTL and computer control of the flash unit in
camera modes
m
,
T
and
A
. Fixed –1
2
/
3
EV preset for automatic
program mode and normal lighting conditions, manual com-
pensation (± 3
1
/
3
EV) also possible.
On the LEICA SF20, ± 3 EV can be set in
1
/
3
EV steps with TTL
control or in 1 EV steps with computer control.
Automatic adjustment of flash reflector for system-compa-
tible SCA 3000/3002 standard flash units with motor zoom
reflector, SCA 3501/3502M3 adapters and lenses with electri-
cal contacts.
Viewfinder system
Prism Built-in penta prism
Eyepiece High-eye-point viewfinder. Diopter compensation of
approx. ± 2 dpt. can be set on the viewfinder. Additional correc-
tive lenses from 3 to + 3 dpt. are available. Built-in eyepiece
lock.
Focusing screens Interchangeable, 5 models available:
Universal screen (ground glass screen with micro-prism ring
and split-image, standard equipment), uniform ground glass
screen, uniform ground glass screen with grid divisions, micro-
prism screen, clear glass screen with cross hairs
Viewfinder field 23 x 35mm, equivalent to 93% of film format
(96% vertical x 97% horizontal) and the standard slide for
mat.
Magnification
0.75 x with 50mm lens set to infinity and 0 dpt.
Displays
Viewfinder LCD lines below viewfinder image showing: Warning
symbol if below metering range, indication of exposure com-
pensation or manual film speed setting differing from DX value,
symbols for metering method incl. display for metering
memory-lock, flash symbol, flash ready and flash check, flash
exposure compensation, mode display, aperture display in half
steps, including values dependent on focal length for zoom lenses
with variable aperture, light balance for manual exposure
adjustment, exposure compensation, automatic exposure
series and metering flash mode, shutter speed or over/under-
exposure signals, long-time exposure signal or for impossible
camera settings, frame counter with display of multiple exposu-
res, automatic exposure series and incorrectly loaded film
205


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Leica R9 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Leica R9 in the language / languages: German as an attachment in your email.

The manual is 1,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info