Configuration
The system has to be configured with a Palmtop before it is ready for use (configuration is transferred via
IrDA optical Port and includes machine number, password and de-counter).
Configuration is uploaded on the Palmtop with Paytec “Configurator" (via PC serial Port).
Recharging Selections
The number of selections available has to be updated whenever a client receives coffee capsules (the
current number of selections available is increased by the number of new capsules received).
Such an operation is only possible with a Palmtop (via optical IrDA interface) : first, the Palmtop reads and
displays the number of selections still available on the machine, then the Palmtop application automatically
calculates and uploads new selections (the selections uploaded are added to the residual ones).
Audit Data
Audit data can be only downloaded via an optical IrDA interface using protocol “Data Transfer Standard
EVA-DTS 6.0”. Here below are the parameters for the Serial port :
2400 Baud Rate, 8 Data Bits, Parity None, 1 Stop Bit
Position the Palmtop so that its optical reader is facing the transparent Port on the machine and start
downloading. The file contains the following data:
File format
Field Description
DXS*FAG*VA*1 DXS
Audit header
ID1*FAGABCDEFGHLMOP12345678*
FAG SECURX*10000*0*1.00.00*1
ID1 *FAG + machine no.*model no.*sw.rev.***1
EA3*2*101013*1033**101013*1033 EA3
*No. readout * date current readout * time current
readout * date last readout * time last readout
EA7*0*9 EA7
*No. power ON since last readout * No. power ON
since initialization
VA1**8**5 VA1
** No. total selections ** No. selections since last
readout *
SA1**30 SA1
** No. Selections available (de-counter)
DXE*1*1 DXE
End Audit data
Notes
Data meet the standards of EVA-DTS protocol.
Date/time are taken from the Palmtop used (the Palmtop clock/calendar should be checked periodically).
Machine number is taken from the configuration downloaded with the Palmtop.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lavazza EP2100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lavazza EP2100 in the language / languages: English as an attachment in your email.

The manual is 0,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info