Filling
Please refer to the last two pages of the manual.
Unscrew the appropriate cap (16) and fill the boiler with water. To fill
it up use the bottle (9) provided: it has an anti-overfill device which
stops the flow when the boiler is full (the capacity of the bottle is
greater than that of the boiler).
Squeeze the bottle briefly to start the filling of the boiler. Once full,
screw the filling cap back on again (16) as far as it will go.
3
Fix the board in the highest
position. Put the rinsing recep-
tacle beneath the boiler.
Unscrew the drain cap (15).
Unscrew the filling cap (16).
Pass the contents of a bottle (9)
of hot water through the boiler
to rinse it. Screw the drain cap
back on again (15).
Screw the filling cap back on
again (16).
CAUTION: Fill up the boiler
before every use.
Première utilisation
Using for the first time
System disconnected Rinsing the boiler
Always unplug the mains before
filling the boiler.
What sort of water to choose?
Getting started
Always fill the boiler with water before starting to iron as it could be damaged if heated up while empty.
CAUTION: Heating up without water invalidates your system’s guarantee.
Filling before using the system
Water hardness test included.
English
MagicEVO2-PreEVO2 Anglais.qxp 20.5.2009 9:53 Uhr Seite 5
Switches
Setting of the iron temperature
4
2. Turn on both switches and
wait until the green light comes
on (approx. 7 to 8 minutes).
1. Insert the plug.
7-
8 min
Steam button
Vacuum / Blowing - choice of 2 speeds
A single steam control button situated on the iron allows you to both start the emission of steam and
switch from “blowing” mode to “vacuum” mode (or vice versa).
Changing from one mode to the other can be done only when the motor is off. The chosen mode stops
automatically at the end of a cycle (lasts 4 seconds). At that moment you may select the desired mode.
In addition to the vacuum and blowing functions, the steam control button enables the strength of the
flow of air from the ventilator to be regulated. When the iron is switched on, the ventilator is pre-set to
maximum capacity (100%). Changing from one mode to the other can be done only when the motor is off.
To change to reduced airflow (50%), press the steam control button twice very quickly. To go back to
maximum airflow, press the steam control button twice again.
Ironing
Position "A":
Normal temperature
Without Softpressing soleplate:
- cotton, linen.
With Softpressing soleplate:
- wool, silk, synthetics.
Position "B":
Low temperature
With Softpressing soleplate:
- for extremely delicate synthetics
eg: synthetic velours, Alcantara®
(synthetic suede), sport stretch
garments.
Check that the indicator light of the iron is also on before ironing.
ATTENTION:
After a change of setting it takes about 2 mins for the new temperature to stabilize!
If the iron spurts water, slightly increase the temperature.
Before starting to iron or after lengthy ironing interruption, press the steam button 2 or 3 times to evacu-
ate any water which may have condensed in the steam tube.
English
MagicEVO2-PreEVO2 Anglais.qxp 20.5.2009 9:53 Uhr Seite 6
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Laurastar premium evolution at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Laurastar premium evolution in the language / languages: English as an attachment in your email.

The manual is 4.91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Laurastar premium evolution

Laurastar premium evolution User Manual - German - 14 pages

Laurastar premium evolution User Manual - Dutch - 15 pages

Laurastar premium evolution User Manual - French - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info