646815
27
Zoom out
Zoom in
Previous page
1/92
Next page
ThermoSpot Plus
b
d
e
c
a
f
g
i
h
Laserstrahlung!
Nicht in den Strahl blicken.
Laser Klasse 2
< 1 mW · 650 nm
EN 60825-1:2007-10
Rev.1114
ThermoSpot Plus
4
Laserstrahlung!
Nicht in den Strahl blicken.
Laser Klasse 2
< 1 mW · 650 nm
EN 60825-1:2007-10
Rev.1114
ThermoSpot Plus
Laserstrahlung!
Nicht in den Strahl blicken.
Laser Klasse 2
< 1 mW · 650 nm
EN 60825-1:2007-10
Rev.1114
ThermoSpot Plus
5
Laserstrahlung!
Nicht in den Strahl blicken.
Laser Klasse 2
< 1 mW · 650 nm
EN 60825-1:2007-10
Rev.1114
ThermoSpot Plus
Laserstrahlung!
Nicht in den Strahl blicken.
Laser Klasse 2
< 1 mW · 650 nm
EN 60825-1:2007-10
Rev.1114
ThermoSpot Plus
1x
Per eseguire una
misurazione costante
attivare il laser (vedi gura)
e tenere premuto il tasto.
Misura permanente / Hold
Visualizzazione MAX
Avvertimento laser
Cerchio laser
Questo cerchio serve per mirare e visualizzare il punto per la
misurazione a raggi infrarossi. La misurazione della temperatura
avviene solo sulla supercie che si trova all’interno del cerchio laser.
Accertarsi che non vi siano interferenze nel campo di misura tra
l‘apparecchio e la supercie da misurare (vapore, gas, sporco o vetro).
Uscita del raggio laser
Non appena il punto
da misurare è stato
rilevato con la circonferenza
laser, rilasciare il tasto. Il valore
misurato rimane visualizzato.
Raggio laser attivo
Carica delle batterie
Funzione Hold
Visualizzazione dei valori misurati
Valore max. durante la misurazione /
Grado di emissione
Illuminazione del display
Unità di misura °C
Regolazione del grado di emissione
ON / Misura
a
b
c
d
e
f
g
h
i
La visualizzazione MAX rileva il valore misurato massimo
nell‘ambito di una misura continua (tenere premuto il
grilletto). Rilasciando il grilletto ed avviando una nuova
misura ripremendo il grilletto, il valore MAX viene azzerato
e la registrazione del valore misurato massimo inizia di
nuovo.
27
IT
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Laserliner ThermoSpot Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Laserliner ThermoSpot Plus in the language / languages: All languages as an attachment in your email.

The manual is 6,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info