ENGLISH10
SuperCross-Laser SCL 2
Checking the vertical line: Position the device about 5 m from a wall. Fix a plumb bob with a line
of 2.5 m length on the wall, making sure that the bob can swing freely. Switch on the device and
align the vertical laser to the plumb line. The precision is within the specified tolerance if the deviati-
on between the laser line and the plumb line is not greater than ± 1.5 mm.
Checking the horizontal line: Position the device about 5 m from a wall and switch on the cross
laser. Mark point B on the wall. Turn the laser cross approx. 2.5 m to the right and mark point C.
Check whether the horizontal line from point C is level with point B to
within ± 2 mm. Repeat the process by turning the laser to the left.
Performing the calibration check:
3. Position the device as near as possible to
the wall at the height of point A1.
4. Turn the device through 180° and mark
point A3. The difference between points
A2 and A3 is the tolerance.
Preparing the calibration check:
It is possible for you to check the calibration of the laser. To do this, position the device midway
between 2 walls, which must be at least 5 metres apart. Do this by turning the unit on, thus
releasing the transport restraint (cross laser on). Please use a tripod.
1. Mark point A1 on the wall.
2. Turn the device through 180° and mark
point A2. You now have a horizontal
reference between points A1 and A2.
A1
A2
2.
1.
Note:
If points A2 and A3 are more than 5 mm / 10 m, the device is in need of calibration. Contact
your authorised dealer or else the UMAREXLASERLINER Service Department.
A3
A2
A3
A2
A2
A1
4.
3.
<
5 mm / 10 m = OK
B
C
2,5 m
< 2 mm = OK
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Laserliner SuperCross-Laser 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Laserliner SuperCross-Laser 2 in the language / languages: All languages as an attachment in your email.

The manual is 1,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info