646790
14
Zoom out
Zoom in
Previous page
1/64
Next page
Checking the vertical line: Position the device about 5 m from a wall. Fix a
plumb bob with a line of 2.5 m length on the wall, making sure that the bob
can swing freely. Switch on the device and align the vertical laser to the plumb
line. The precision is within the specified tolerance if the deviation between the
laser line and the plumb line is not greater than ± 1.5 mm.
Checking the horizontal line:
Position the device about 5 m from a wall and
switch on the cross laser. Mark point B on the wall.
Turn the laser cross approx. 2.5 m to the right and
mark point C. Check whether the horizontal line
from point C is level with point B to within ± 2 mm.
Repeat the process by turning the laser to the left.
Performing the calibration check:
3. Position the device as near as possible to the wall at the height of
point A1.
4. Turn the device
through 180° and
mark point A3. The
difference between
points A2 and A3 is
the tolerance.
Preparing the calibration check:
It is possible for you to check the calibration of the laser. To do this, position
the device midway between 2 walls, which must be at least 5 metres apart.
Switch the device on (Laser cross ON). The best calibration results are achie-
ved if the device is mounted on a tripod. 1. Mark point A1 on the wall.
2. Turn the device
through 180° and
mark point A2.
You now have a
horizontal reference
between points A1
and A2.
A1
A2
2.
1.
Note: If points A2 and A3 are more than 1 mm / 10 m, the device is in
need of calibration. Contact your authorised dealer or else the UMAREX-
LASERLINER Service Department.
B
C
2,5 m
< 2 mm = OK
A3
A2
A3
A2
A2
A1
4.
3.
<
1 mm / 10 m = OK
PrecisionCross-Laser PCL 8
ENGLISH14
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Laserliner PrecisionCross-Laser PCL 8 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Laserliner PrecisionCross-Laser PCL 8 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Spanish, Finnish as an attachment in your email.

The manual is 2,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info