BAT. Battery charge status measurement
To measure the battery charge status, set the rotary switch to
the "BAT." position with the corresponding measuring range.
1.5 V = 1.5 V round cells / AA, AAA, C, D
1.2 V round cells (NiMH) / AA, AAA, C, D
9 V = 9.0 V flat cells / E-block
8.4 V flat cells (NiMH) / E-block
Then connect the measuring contacts to the battery.
20
300 300
10A
BAT.
9V
BAT.
1.5V
200200
2000
m
200
m
2000
k
200
k
20k
2000
200
200m
20m
2000
μ
7
The battery voltage is shown on the display. You can read off the
battery charge status from the following scale.
Good: battery fully charged
Weak: battery is weak and will soon need replacing
Replace: battery is at and should be replaced
Example
Battery: Alkaline 9 V
Measured voltage: 6.2 V
Battery charge status: weak
black red
Do not measure currents above 2 A for longer than
10 seconds within 15 minutes. This could damage the
device or the test prods.
Current above 200 mA must not be measured in the
μA / mA range and currents above 10 A must not be
measured in the A range. Otherwise the corresponding
built-in fuse will trip (F 250 mA / 300 V, F 10 A / 300 V,
Ø 5 mm x 20 mm).
!
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Laserliner MultiMeter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Laserliner MultiMeter in the language / languages: English, German, Dutch, Danish, French as an attachment in your email.

The manual is 5,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info