646769
10
Zoom out
Zoom in
Previous page
1/40
Next page
Position the unit at the height of point a1 as close to
the wall as possible and adjust the unit in the Xaxis.
4 Turn the device through 180° and mark point A3. The
difference between points A2 and A3 is the tolerance
for the X axis (P. 9).
5 If points A2 and A3 are more than 2 mm / 10 m apart
the device is in need of calibration. Remove cover for
laser calibration and adjust laser to point A2 using
enclosed
allen wrench.
6 Mark point D and switch unit on. Project plumb of D
to ceiling and mark point E. Turn unit 180 ° and
project again from D to ceiling and mark point F. The
difference between E and F is the tolerance for the
Z-axis.
7 Should E and F be more as 4 mm / 10 m apart the
plumb laser must be calibrated. Remove cover for
calibrating and adjust laser between point E and
point F.
Preparing the calibration check
It is possible for you to check the calibration of the laser. To do this, position the device midway between 2
walls, which must be at least 5 metre apart. Switch the
device on. The best calibration results are achieved if the
device is mounted on a tripod.
1 Mark point A1 on the wall.
2 Turn the device through 180° and mark point A2.
You now have a horizontal reference between points
A1 and A2.
ENGLISH10
MultiBeam-Laser MBL 3
A1
A2
2
1
A3
180°
A2
<
2 mm / 10 m = OK
A3
A2
A2
A1
4
3
EFFE
min. 5 m
D
6
DD
Performing the calibration check
3 Position the device as near as possible to the wall at the height of point A1. Adjust the device in the
X axis.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Laserliner MultiBeam-Laser MBL 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Laserliner MultiBeam-Laser MBL 3 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Spanish, Finnish as an attachment in your email.

The manual is 1,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info