646711
15
Zoom out
Zoom in
Previous page
1/136
Next page
Centurium Express
15
ON
External
influence
Adjustment phase
Sensor Automatic
ADS activation:
press tilt button;
long flash of tilt
LED at 1 second
intervals.
The
laser
remains stationary as
a precaution, the laser
flashes and the tilt
LED is lit continuously.
ADS active after
30 seconds; short
flash of tilt LED at
1 second intervals.
Rotation
begins
ADS function
The ADS does not activate the monitoring function until 30 seconds
after the laser levelling procedure has been completed (set-up phase).
Long flash of tilt LED at 1 second intervals during the set-up phase
and short flash of LED when ADS is active.
!
Special product features and functions
The rotary laser aligns itself automatically. It is set to the
required initial position (to within an operating angle of ± 5°) and the
automatic system then performs the necessary fine adjustment, with
three electronic measurement sensors detecting the X, Y and Z axes.
The anti-drift system (ADS) prevents erroneous or inaccurate
measurements. How it works: continuous monitoring of the alignment of
the laser is activated 30 seconds after the ADS is switched on. If the device
moves due to the influence of external factors or the laser loses its height
reference, the laser will come to a standstill. Additionally, the laser flashes
and the tilt LED is lit continuously. To continue working, press the tilt button
again or switch the device off then on again. Erroneous and inaccurate
measurements are thus prevented simply and reliably.
The ADS is not active following switch-on. Once the device has been set
up, press the tilt button to activate the ADS, enabling you to protect the laser
from changes in position caused by the device being disturbed by external
factors. The tilt LED flashes to indicate that the ADS function is active; see
the diagram below.
GB
Manual_Centurium_Express_Rev.0312_Klasse3R_Part 1.indd 15 29.03.12 15:01
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Laserliner Centurium Express 310S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Laserliner Centurium Express 310S in the language / languages: All languages as an attachment in your email.

The manual is 2,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info