577628
12
Zoom out
Zoom in
Previous page
1/60
Next page
ENGLISH
A
1
A
2
2.
1.
Preparing the calibration check:
It is possible for you to check the calibration of the laser.
To do this, position the device midway between 2 walls,
which must be at least 5 metres apart. Switch the device
on (indicator lamp 11 off). The best calibration results
are achieved if the device is mounted on a tripod.
1. Mark point A1 on the wall.
2. Turn the device through 180° and mark point A2.
You now have a horizontal reference between points
A1 and A2.
Note: If points A2 and A3 are more than 3 mm / 10 m
apart on either, the device is in need of calibration.
Contact your authorised dealer or else the UMAREX-
LASERLINER Service Department.
Testing accuracy of vertical line
Set up instrument about 5 m from a wall. Fix a plumb line
of 2.5 m length to the wall, using a plumb bob. Press
button V1 or V2 and bring laser line into coincidence with
the plumb line. Deviation between laser line and plummet
cord from top to bottom must not exceed ±1.5 mm.
Testing accuracy of horizontal line
Set up instrument about 5 m from a wall. Press buttons H
and V1. Mark laser cross on wall. Turn instrument until the
laser cross has moved about 2.5 m to the left side and
check if horizontal line is within
± 2 mm of laser cross marked
on wall. Repeat measurement
by turning instrument to the
right side.
AutoCross Laser ACL 2
Performing the calibration check:
3. Position the device as near as possible to the wall at
the height of point A1. Now adjust the device.
4. Turn the device through 180° and mark point A3.
The difference between points A2 and A3 is the
tolerance.
A
3
A
2
<
3 mm / 10 m = OK
A
3
A
2
A
2
A
1
4.
3.
12
B
C
2,5 m
< 2 mm = OK
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Laserliner AutoCross Laser ACL 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Laserliner AutoCross Laser ACL 2 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Spanish, Finnish as an attachment in your email.

The manual is 2,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info