English 8 / 40
Lanaform cannot be held liable in the event
of accidental damage resulting from any use
contrary to the instructions given in these
instructions for use.
MAINTENANCE AND STORAGE
When you are not using the
diuser, empty the water out
of the reservoir. Do not tip the
water out of the reservoir from
the exhaust vent side. If the water
gets into the exhaust vent, this
might damage the device!
[
4]
To prevent this from happening:
Use a container to pour water into the
reservoir.
Do not shake the diuser.
Do not move the diuser when there is
water in the reservoir.
If water accidentally enters the exhaust vent
[
5
1]
, there is a safety device for removing
water from the base of the diuser:
Disconnect the power cable from the
diuser.
Empty the reservoir completely through
the opposite side to the exhaust vent.
Bend the diuser towards one of the
drainage holes [
5
2] to empty the water.
Leave the diuser in a dry place for 24
hours.
Always unplug the device with
dry hands before cleaning it!
Maintenance
If the water contains too much calcium and
magnesium, it may deposit a white powder
in the device. If this foam is deposited on the
transducer
[
1
7]
, it will prevent the device
from working properly.
We recommend:
1 Using distilled or demineralised
water each time it is used.
2 Cleaning the reservoir every 2 days and
cleaning the transducer every week.
3 Emptying and cleaning the device
(see explanations below) and making
sure that all its parts are complete-
ly dry when it is not in use.
To clean the transducer
[
]:
1 Put 2 to 5 drops of vinegar on its surface
and leave them there for 2 to 5 minutes.
2 Brush the foam o the surface with a
soft brush or cotton bud. Do not use
a hard tool to scrape the surface.
3 Do not use soap, solvent or spray
cleaner to clean the transducer.
To clean the reservoir and reservoir cover:
1 Use a soft cloth and vinegar if
there are any foam or limes-
cale deposits on the inside.
2 Rinse them in clean water.
Do not use products containing
bleach to clean the device, but
washing up liquid or vinegar only!
Do not immerse the
base
[
1
9] in water!
Storage
Having cleaned and dried the device, store it
in a dry, cool place out of the reach of children.
BREAKDOWNS
AND SOLUTIONS
In the event of a malfunction under nor-
mal conditions of use, please refer to the
following list:
No mist.
If there is no light.
Check that the device is connected
and that there is no mains fault.
The water level in the
reservoir is too low.
Add water to the reservoir.
Water is leaking from the reservoir.
Check that the reservoir is
in the right position.
The temperature of the unit is too low.
Place the unit in a room at
ambient temperature for
half an hour prior to use.
Mist has an unusual smell.
The water has been standing in
the reservoir for too long.
Clean the reservoir and pour fresh,
distilled or demineralised water into it.
Low intensity.
Too much/too little water
in the reservoir.
Empty water out of the
reservoir or add water to it.
Sediment on the transducer.
Clean the transducer.
The water is too cold.
Use water that is at room temperature.
The water is not clean.
Clean the reservoir and pour fresh,
distilled or demineralised water into it.
TECHNICAL FEATURES
Reference: LA
Power supply: DC  V
Consumption: W
Reservoir capacity: ml
Emission rate: -ml/h
Dimensions:  ×  ×  cm
EN FR NL CS SK SL RO BG LT
E-IM-Moya-001-2019.indd 8 12/08/2019 11:59:06
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lanaform LA120322 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lanaform LA120322 in the language / languages: English, Dutch, French as an attachment in your email.

The manual is 1,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info