NON-CONTACT INFRARED
FOREHEAD THERMOMETERGB GBEnglish EnglishInstructions and guarantee
4) Replace the battery cover.
Dispose of the old battery as special waste at designated collection points
for recycling. For more information about disposal of used batteries,
contact the store where you purchased the appliance containing the
batteries, the municipality or the local waste disposal service.
Attention: For added security we do not recommend that children
under 12 years old remove the batteries.
INSTRUCTIONS FOR PROPER USE
FOREHEAD TEMPERATURE RECORDING ( )
Attention!
In order to ensure accurate recording of the temperature, clean the probe
in its entirety with a cotton swab moistened with alcohol after each use.
Make sure that the probe is completely dry before use.
IMPROPER CLEANING OF THE PROBE CAN CAUSE UNRELIABLE
TEMPERATURE RECORDINGS
1) Clean and dry the forehead where you will position the probe.
2) Turn on the thermometer by pressing the O/I button on the display. All
the function symbols will appear (self-test).
After a few seconds the display will show the forehead measurement
icon (see fig. 2) and will beep twice. At this point, the thermometer
is ready for use.
3) Position the probe over the forehead at a distance of about 1 to 3 cm.
4) Press and hold the SCAN button until the thermometer beeps. At
this point, release the SCAN button, the appliance will give two short
beeps and the display will show the temperature measured. When
you proceed with a new measurement, the display will show in the
top right corner the preceding measurement and the icon (see
fig. 3). When the temperature measured is above or equal to 37.5°C
(99.5°F) the thermometer will emit 3 short beeps.
NB: The temperature shown on the display is equivalent to the
oral temperature, i.e. the temperature recorded at the forehead is
translated as if the temperature had been recorded in the mouth.
5) After 1 minute of non-use the appliance will switch to standby mode
CELSIUS/FAHRENHEIT
This thermometer can measure temperature in Celsius and Fahrenheit. If
you wish to change the unit of measurement, proceed as follows:
1) When the thermometer is in stand-by mode (fig. 4), press and hold
the SCAN button for a few seconds and simultaneously press the O/I
button until the display shows°F (or°C), see fig. 5.
2) The thermometer will beep twice. At this point, release the buttons.
Now the unit of measurement has been changed. Proceed with the
measurement as described in the “INSTRUCTIONS FOR PROPER USE”
section.
MEMORY FUNCTION
This appliance stores the last 25 measurements to allow you to assess
any changes. The measurements are stored automatically after the
thermometer goes into standby mode. Only the forehead temperatures are
stored. After 25 measurements, the oldest measurement will be cancelled
after each new measurement.
To recall stored measurements, activate the thermometer and press the
O/I button (each press of the button causes the data in memory to scroll).
On pressing the button, the display shows the serial number of each
measurement in memory (1 = most recent measurement, 25 = oldest).
At top left of the display the M symbol appears (see fig. 6). When you
release the button, instead of the serial number, the display shows the
measured temperature.
Stored values are displayed for about 1 minute.
About 1 minute after you release the O/I button, the appliance goes into
standby mode and displays the ambient temperature ( icon , see fig.
4), or you can turn it off by pressing and holding the O/I button for a
few seconds.
CLEANING AND MAINTENANCE
Before and/or after each use, clean the probe of the thermometer with a
cotton swab moistened with alcohol to ensure accurate readings.
The probe is the most delicate part of the thermometer, pay particular
and display the ambient temperature (icon , see fig. 4), or you can
turn it off by pressing and holding the O/I button for a few seconds.
RECORDING THE AMBIENT TEMPERATURE ( )
This thermometer can record the ambient temperature.
The appliance after 1 minute of non-use switches to standby mode and
displays the ambient temperature ( ).
NB: Only after 15 minutes of non-use in standby mode ( ) is the
temperature shown on the display equivalent to the actual ambient
temperature.
When turned on again, the display shows the forehead temperature
recording function.
INFRARED SCAN FUNCTION ( )
This thermometer can record the temperature of warm surfaces or liquids
(such as milk, water, ...).
1) Turn on the thermometer by pressing the O/I button. The display will
show all the function symbols (self-test) and after a few seconds the
display will show the forehead measurement icon (see fig. 2) and will
beep twice.
2) Press and hold the “O/I” button for a few seconds and simultaneously
press the “SCAN” button.
The display will show the icon ( disappears).
3) To measure temperature using the SCAN function bring the
thermometer to the surface in question (container of water, milk,
...) as shown in fig. 7. If you press and hold the SCAN button, the
temperature is continuously updated.
4) The apparatus after 1 minute of non-use switches to standby
mode and displays the ambient temperature ( icon , see fig. 4),
or you can turn it off by pressing and holding the O/I button for a
few seconds. When turned on again, the display shows the forehead
temperature recording function ( ).
NB: Never immerse the probe in any kind of liquid.
attention to it during cleaning.
Allow the probe to dry completely for at least 30 minutes. The body of the
thermometer should be cleaned with a soft, dry cloth.
THE BODY OF THE THERMOMETER MUST NOT BE WASHED WITH WATER.
Never use abrasive products and do not immerse the thermometer in water
or other liquids. Keep the thermometer in a clean, dry place, away from
direct sunlight.
TROUBLESHOOTING
Problem: The thermometer measurements are lower than the actual
temperatures
Solution: Check the correct positioning of the probe at the forehead.
Reread the section, “Forehead Temperature Recording”.
The sensor may be dirty, clean it before and/or after each use
with a cotton swab and alcohol.
Image 1
Problem: Low battery.
Solution: Replace the battery.
Image 2
Problem: The display shows “Er1”. The measurement was made before
device setup.
Solution: Wait a few seconds until the icon stops flashing.
Image 3
Problem: The display shows “Er3”. The room temperature is not
between 10°C and 40°C / 50°F and 104°F.
Solution: The thermometer must already be in the room in which you
will perform the measurement about half an hour before
taking measurement while the person must be in the room
at least 30 minutes before too.
(The room temperature must be between 10°C and 40°C /
50°F and 104°F).
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Laica TH1002 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Laica TH1002 in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info