TROUBLESHOOTING 18
5.
TROUBLESHOOTING
This symbol means that a qualified professional should be called to perform the operation.
Problem
Probable causes
Solution
The fire does not light
properly
The fire does not stay
alight
Green or damp wood
Use hard woods, cut at least 2 years ago and stored in a
sheltered, ventilated place
The logs are too large
Use crumpled paper or firelighters and dry wood chips to light
the fire. Use split logs to keep the fire going
Poor-quality wood
Use hard woods which produce heat and embers (chestnut, ash,
maple, birch, elm, beech, etc.)
Insufficient primary air
Open the primary- and secondary-air intakes completely, or
even open the door slightly.
Open the outdoor-air inlet grille
Insufficient updraught
Check that the draught is not blocked. De-soot if necessary.
Check that the flue is in perfect condition (airtight, insulated,
dry, etc.)
The fire flames up too
much
Excessive primary air
Close the primary- and secondary-air intakes partially or totally
Excessive updraught
Install a draught damper
Smoke given off on
lighting
Poor-quality wood
Do not continually burn chips, carpentry scraps (plywood,
pallets, etc.)
Cold flue
Heat up the flue by burning a piece of paper in the firebox.
Smoke during burning
The room is at low
pressure
In rooms with Controlled Mechanical Ventilation, leave an
outdoor window ajar until the fire is fully alight.
Too little wood loaded
Load as recommended. Loads notably smaller than those
recommended lead to low smoke temperature and
downdraught.
Insufficient updraught
Check the condition of the flue and insulation.
Check that the piping is not blocked. Clean mechanically if
necessary
Wind enters the flue
Install an anti-downdraught system (Cowl) at the top of the
chimney
Does not warm up enough
The room is at low
pressure
In rooms with Controlled Mechanical Ventilation, there must be
an outdoor-air inlet
Poor-quality wood
Only use the recommended fuel
Water condenses (after
the appliance has been lit
more than 3 or 4 times)
Too little wood loaded
Load as recommended. Loads notably smaller than those
recommended lead to low smoke temperature and
condensation.
Green or damp wood
Use hard woods, cut at least 2 years ago and stored in a
sheltered, ventilated place.
Condition of the flue
Lengthen the flue (5-6 metres minimum). Insulate the flue
properly. Check the airtightness of the flue/appliance.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Lacunza Bidart at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Lacunza Bidart in the language / languages: English as an attachment in your email.

The manual is 2.1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Lacunza Bidart

Lacunza Bidart User Manual - German - 28 pages

Lacunza Bidart User Manual - French - 24 pages

Lacunza Bidart User Manual - Spanish - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info