INSTRUCTIONS OF USE 14
3.
Figure No.10 - Combustion air intakes
1- Primary air inlet; regulates the air under
the grate.
2- Secondary air inlet; regulates the air for
the glass (air-wash).
3- Double combustion air inlet; the back
wall has permanent vents below the
baffle plate that allow for post-
combustion. Is not adjustable.
3.7. Removing ash
Following sustained use of the
appliance, it is necessary to remove the ash
from the firebox. Remove the ashpit box
when cold or using something to prevent
yourself from getting burned (glove).
Never throw hot embers into the
rubbish.
Access the ashpit by opening the door
on the appliance.
3.8. Deflectors.
The appliance has 2 vermiculite
deflectors and a stainless-steel
reinforcement that joins them together.
Dismantling the Bidart deflector
First extract the stainless-steel
reinforcement.
In order to do this, rotate the
reinforcement as shown:
Figure No.11 - Rotate the reinforcement
Then, draw it towards the front of the
appliance to release it from the vermiculite
parts.
Figure No.12 - Release the reinforcement
Finally, the vermiculite deflectors can
be extracted as shown: