INSTRUCTIONS OF USE 15
3.
burned in the first combustion. This
increases the performance of the appliance
and reduces emissions.
On Ocean models, the double-
combustion air intake is the same as the
secondary-air intake (both air intakes are
controlled through the same inlet at the
same time).
IMPORTANT: The appliance is exposed to
extreme changes in temperature and may,
as a result, make noises when in operation.
These noises are a natural result of
expansion/contraction of the parts which
make up the appliance. Do not be alarmed
by noises of this kind.
In order to obtain maximum output,
open all the air intakes to the firebox and
in order to obtain minimum output, tend
towards closing them. For normal use, we
recommend you close the Primary Intake
and leave the Secondary and Double
Combustion Intakes open.
3.7. Removing ash
Following sustained use of the
appliance, it is necessary to remove the ash
from the firebox. Remove the ashpit box
when cold or using something to prevent
yourself from getting burned (glove).
Never throw hot embers into the
rubbish.
Access the ashpit by opening the door
on the appliance.
3.8. Deflectors
The appliance has 2 vermiculite
deflectors and a stainless-steel
reinforcement that joins them together.
Dismantling the Ocean deflector
First extract the stainless-steel
reinforcement. In order to do this, draw it
towards the front of the appliance to
release it from the vermiculite parts.
Figure No.11 - First movement to release
the reinforcement
Then rotate the reinforcement as
shown:
Figure No.12 - Turning the stainless-steel
reinforcement
Let the stainless-steel reinforcement
drop onto the vermiculite deflectors.
Figure No.13 - Reinforcement on the
vermiculite deflectors