812600
14
Zoom out
Zoom in
Previous page
1/36
Next page
MANUAL FOR USE AND MAINTENANCE
14 LSC 001 -UK- REV. 06
2.3 ROUTINE APPLIANCE MAINTENANCE TO BE PERFORMED BY THE USER
NOTE. To grant the efciency of the appliance and to maintain correct operation, it is necessary
to follow the manufacturer’s instructions as to cleaning and regular maintenance.
WARNING!
Cleaning and routine maintenance operations must be carried out by the user according to the
manufacturer’s instructions given here below. Before carrying out any kind of cleaning operation,
disconnect the appliance from the electricity mains and from the gas system (if tted). Cleaning
and routine maintenance operations must be carried out when the machine is cold and using
protective gloves to prevent abrasions.
DAILY AT THE END OF THE JOB
1a) Replacing the water in the boiler (Range New - Rapid - Spazio).
After turning off the appliance, replace the water in the boiler as follows:
Place a container that can withstand high temperatures below the hot water nozzle (7) to prevent any
hot water spills.
Turn the hot water knob (6) anticlockwise until the boiler is completely empty, checking the level gauge
(2). Rell the boiler immediately using the manual lling button (1).
1b) Replacing the water in the boiler (Range S3 - EK – EP models).
Place a container that can withstand high temperatures under the hot water nozzle (7) to prevent any
hot water spills.
Press and hold down the hot water knob (6) for at least 5 seconds: the automatic boiler emptying cycle
will begin (all machine controls are deactivated during this phase). On the EK model, the LEDs 18-21
are ashing during this phase while the LEDs 19-20 remain lit.
At the end of the cycle, the appliance restores the correct water level in the boiler through the automatic
rell system. To interrupt this cycle, it is sufcient to hold down the hot water button (6) for about 2
seconds.
Disconnect the appliance.
1c) Replacing the water in the boiler (Range S5 - Compact).
After turning off the appliance, replace the water in the boiler as follows:
Place a container that can withstand high temperatures under the hot water nozzle (7) to prevent any
hot water spills.
Open the hot water valve (6), moving the lever upwards until the boiler is completely empty, checking
the level indicator (2). Rell the boiler immediately using the manual lling button (1).
1d) Replacing the water in the boiler on appliances with timed water delivery (optional) (Range S5).
Place a container that can withstand high temperatures under the hot water nozzle (7) to prevent any
hot water spills.
Press and hold down timed hot water delivery button (42) for at least 5 seconds: the automatic boiler
emptying cycle will begin (all machine controls are deactivated during this phase).
At the end of the cycle, the appliance will restore the correct water level in the boiler using the automatic
ller. To interrupt this cycle, press the hot water delivery button (42).
Disconnect the appliance.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Spaziale RAPID at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Spaziale RAPID in the language / languages: English as an attachment in your email.

The manual is 1.91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info