MANUAL FOR USE AND MAINTENANCE
12 LSC 001 -UK- REV. 06
RANGE NEW - EK MODEL
This model informs users as to possible malfunctions through the LEDs for the 4 preset dose buttons on
the touchpads.
1. LED CORRESPONDING TO THE COFFEE DOSE BUTTON DISPENSING, FLASHING AFTER 5-6
SECONDS:
Coffee ground too nely.
Missing reading of the pulses sent by the ow meter to the delivery group.
After checking the grinding neness, if the problem continues, contact an authorised Service Centre.
2. ALL LEDS CORRESPONDING TO ALL DOSES ON ALL TOUCHPADS FLASHING:
The automatic rell system for the boiler has been in operation for longer than 4 minutes (total block of all machine
functions). To return to the standard operating phase, switch the machine off using the main ON/OFF switch (3). If
this problem is repeated frequently occurs, switch off the appliance and contact an authorised Service Centre.
RANGE S3 EK MODEL
This model informs users as to possible malfunctions through the LEDs on the control panel (13).
Water rell system failure (21-19 lit and 20-18 ashing)
This alarm is a blocking one and is viewed when the automatic rell system for the boiler has been
operating for longer than 4 minutes. To return to the standard operating phase, switch the appliance off
for a second using the ON/OFF switch (3); if the problem persists, switch off the appliance and contact
an authorised Service Centre.
Flow meter failure (the LED corresponding to the delivery group is ashing after 5 seconds)
This alarm is viewed when, during the delivery phase, there is a ow meter malfunction for the delivery
group, or if the coffee has been too nely ground. After checking the grinding neness, if the problem
continues, contact an authorised Service Centre.
Transformer failure (20-18 lit and 21-19 ashing)
This alarm is a blocking one and is viewed when no power (24V) is taken on the transformer secondary,
which is feeding the solenoid valves of the groups and the automatic boiler rell. Contact an authorised
Service Centre.
Stop on P5 (LED corresponding to the dispensing unit lit)
This alarm is viewed when coffee deliveries are carried out with the manual delivery button “ON/OFF” (29) and this
has been in operation for longer than 4 minutes. To cancel the alarm, press the button “ON/OFF” (29) again.
Data loss (21-18 lit and 20-19 ashing)
This alarm is viewed when the data preset by the operator are lost and default data are reset. To cancel
the alarm, press the cup warmer operating button (24). If the problem continues, contact an authorised
Service Centre.
RANGE S5
The appliances of this range of inform users as to possible malfunctions through symbols on the control
panel and touchpads.
1. LED CORRESPONDING TO THE COFFEE DOSE BEING DELIvERED FLASHING AFTER 5-6
SECONDS (EK model only):
Coffee ground too nely.
Missing reading of the pulses sent by the ow meter to the delivery group.
After checking the grinding neness, if the problem continues, contact an authorised Service Centre.
2. ALL DOSE SYMBOLS ON ALL TOUCHPADS FLASHING AND TEMPERATURE SYMBOLS
SWITCHED OFF:
The automatic rell system for the boiler has been operating for longer than 3 minutes (total block of all
machine operations).
2.2 ALARMS CONTROL
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Spaziale NEW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Spaziale NEW in the language / languages: English as an attachment in your email.

The manual is 1.91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info