623545
41
Zoom out
Zoom in
Previous page
1/47
Next page
41
V. Output of controlling
1) Refrigeration control
When measured temp is above (so warmer than requested), compressor should turn ON
When measured temp is below (so cooler than requested) compressor should turn OFF
2) Heating control (winter system)
According to initial information as soon as real temp is 2°C below the set value, heating system starts to operate. The heater is going
to stop working in winter if the surrounding temperature of the wine cabinet is or above 12.
Attention: the compressor and the heater strip are going to run at least 1 minutes after set on.
3) Fan control
The fan starts to work when the compressor or the heater works.
The fan stops to work when the compressor or the heater stops.
4) Alarming
The alarms will turn on 1 minute after detecting an abnomal temperature.
To stop alarm ringing : press a touch on the display (whatever the touch), the alarm will stop ringing.
Humidity turn on/off display content
To change hygrometry alarm status, press at the same time both touch “SET” and “UP” for 3 seconds.
When turn on the humidity voice alarmon the display humidity place will display ON for secondsthis mean the humidity voice
alarm will work.
When turn off the humidity voice alarm, on the display humidity place will display OF for secondsthis mean the humidity voice
alarm will stop work
5) Back light energy-saving mode
The LED will display for 30 seconds. The back light will be turned off if no keys are operated in energy-saving mode(But in this state,
we still can see the message from the screen).If there is no any operation, the screen will not light, until there is a press, the back
light will be turned on. When internal system is set to be permanent light, screen will be permanent light.
Alarming info and some measures:
Alarming code
Meaning
Measures
Indoor temperature is above the high
limit
Press any key to cancel alarm
sound.
Recommendations: immediately
cut off the power supply Please
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Sommeliere TRVE142A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Sommeliere TRVE142A in the language / languages: English, French as an attachment in your email.

The manual is 1,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info