TECHNICAL DESCRIPTION
La NORDICA thermocookers are ideal for holiday ats and weekend houses or as auxiliary heating all year round.
WOODEN LOGS ARE USED AS FUEL. THE APPLIANCE WORKS AS AN INTERMITTENT OPERATING APPLIANCE.
The thermocooker is composed of galvanised steel sheet plates, enamelled cast iron and thermoradiant ceramic. The furnace is found inside
the boiler made with 5 mm thick steel and reinforced with welded nails. The water from the heating system, which absorbs the heat produced
in the furnace, circulates in the boiler.
Inside the furnace, there is a height-adjustable at grill (Picture 8).
The furnace is equipped with a panoramic door with ceramic glass (resistant up to 700°C). This allows a fascinating view of the burning ames.
In addition, in this way there is no possibility of sparks or smoke escaping.
ACCESSORIES CHROME PLATED OVEN GRILLE POKER GLOVE
TermoROSA XXL SERIES SERIES SERIES
THE HEATING OF THE ROOM TAKES PLACE:
A by means of radiation: through the panoramic glass and the hot external surfaces of the stove, heat is radiated into the room.
B by conduction: through radiators or convectors in the central heating system fed by the hot water produced by the Thermocooker
itself.
THE THERMOCOOKER IS SUPPLIED WITH REGISTERS FOR PRIMARY AND SECONDARY AIR AND A THERMOSTAT WITH WHICH THE
COMBUSTION AIR IS REGULATED.
1A - PRIMARY Air Register (Picture 6).
With the lower register, the passage of primary air in the lower part of the cooker is regulated through the ash drawer and the grill in the
direction of the fuel. The primary air is necessary for the combustion process. The ash drawer must be emptied regularly, so that the ash
cannot block the primary air intake for combustion. The primary air also keeps the ame alive.
THE PRIMARY AIR REGISTER MUST BE ALMOST COMPLETELY CLOSED DURING WOOD COMBUSTION, AS OTHERWISE THE WOOD BURNS
TOO QUICKLY AND THE THERMOPRODUCT MAY OVERHEAT.
2A - SECONDARY Air Register (Picture 6).
This register must be opened (and therefore shifted to the right), in detail, for the combustion of wood, so that unburnt carbon can besubject
to a post-combustion, increasing the yield and assuring the cleaning of the glass (see chapter NORMAL OPERATION).
The register regulation necessary in order to obtain nominal caloric output is the following (see Cap. TECHNICAL DATA):
Hourly wood consumption in kg/h PRIMARY air SECONDARY air TERTIARY air
5,2 1/2 OPEN OPEN Pre-adjusted
B - AUTOMATIC Thermostat (Picture 6)
THE THERMOSTAT HAS THE TASK OF AUTOMATICALLY INCREASING OR DECREASING COMBUSTION.
Dependent on the position chosen, the thermostat will act on the valve which regulates the intake of air into the furnace, placed on the
back of the cooker. Turn it in a clockwise direction from 0 to 5 to make up the re and in an anti-clockwise direction to reduce combustion.
AS THIS IS AN EXTREMELY PRECISE DEVICE, IT IS ADVISABLE TO TURN IT CAREFULLY AND NEVER FORCE THE KNOB.
C - FLUE GAS Register (Picture 6)
(Conversion from the cooker HotPLate useoVen use function to the cooker HeatinG function)
When the control is positioned to the LEFT (on the pan symbol), the combustion gases ow above and around the oven (oven function –
HOTPLATE USE – OVEN USE); when positioned to the RIGHT (on the water symbol), the gases ow near the boiler, increasing the temperature
evenly, favouring water heating inside it (cooker function HEATING USE).
D - IGNITION Control (Picture 6).
On the front of the cooker, between the protective handrail and the ue gas control, there is the ignition control lever, which can be
recognised by a chrome-plated knob.
THIS CONTROL MUST ONLY BE USED TO FACILITATE THE IGNITION OF FUEL IN THE COOKER. PULL THE LEVER OUTWARDS FROM THE
COOKER CONTROL OPEN.
IMPORTANT : during normal cooker operation, the control lever must remain completely inserted (pushed inwards on the
cooker). In this way avoiding excessive fuel consumption and poor thermocooker output (control closed).
TO IGNITE THE FLAME (see Cap. IGNITION) :
• Open the ignition register to aid ue gas exhaust. Position the register (any buttery valve placed on the ue gas exhaust pipe must also
be opened).
• Position the thermostat knob on position 5 (maximum opening).
• Open the primary air register (placed on the ash tray).
• After having started the re with small pieces of wood and waited until it is well lit, adjust the thermostat to the positions corresponding
to the desired heat (0÷5).
• Bring the ue gas register to the oven position.
31
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica TERMOROSA XXL DSA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica TERMOROSA XXL DSA in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 8.94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info