696226
27
Zoom out
Zoom in
Previous page
1/101
Next page
ENGLISH
ACCESSORIES
 
SERIES SERIES
Room heating takes place:
a) by radiation: the heat is radiated into the environment through the panoramic window and the hot external surfaces of the thermo-
product;
b) by conduction: radiators or heat convectors of the centralised system fed by hot water produced by the boiler (See chapter
CALCULATION OF THE THERMAL POWER)
The device is equipped with registers of primary and secondary air.
1A- PRIMARY air register (Picture 6)
With the primary air control is adjusted the passage of air through the ash drawer and the grate in the fuel direction. The primary air is
necessary for the combustion process. The ash drawer must be regularly emptied, so that the ash does not obstruct the primary air entry.
Through the primary air the re is also kept alive.
During wood combustion, the register of primary air must be opened only for a while, because otherwise the wood burns fast and the
stove may overheat.
2B - SECONDARY air register (Picture 6)
Over the door of the hearth there is the secondary air control. This regulator must be open (the lever must be moved to the right),
especially for wood combustion, so that un-burnt carbon does not undergo a post-combustion. See chapter 10. Through this register it is
possible to adjust the power of the stove.
Leaving it slightly open, according to the ue of the chimney, it is possible to keep the glass clean.
The adjustment of the registers necessary to reach the rated caloric yield is the following one :
 
PRIMARY air SECONDARY air TERTIARY AIR
    
FLUE
Essential requirements for correct appliance operation:
the internal section must preferably be circular;
the appliance must be thermally insulated and impermeable and built with suitable materials which are resistant to heat,
combustion products and any condensation;
there must be no narrowing and vertical passages with deviations must not be greater than 45°;
if already used, it must be clean;
all the sections of the ue gas duct must be accessible to inspection;
inspection openings must be provided for cleaning.
the technical data from the instruction manual must be respected;
If the ues are of a square or rectangular section, the internal edges must be rounded with a radius of not less than 20 mm.
For the rectangular section, the maximum ratio between the sides must be ≤ 1.5.
A section which is too small causes a reduction in draught. A minimum height of 4 m is advisable.
The following materials are FORBIDDEN and compromise the good operation of the appliance: asbestos cement, galvanised steel, rough and
porous internal surfaces. Picture 1 shows some example solutions.
For a correct installation please respect the sections/lengths of the ue shown in the technical data table. By installations
with dierent dimensions the ue must be suitably sized in accordance with EN13384-1.
The draught created by your ue must be sucient but not excessive.
A section of the ue which is too large can present a volume which is too large to heat and therefore cause operating diculties for the
appliance; to avoid this, it is necessary to intubate the appliance for its entire height. A section which is too small causes a reduction in draught.
ATTENTION: as far as concern the realisation of the ue connection and ammable materials please follow the requirements
provided by UNI 10683 standard. The ue must be at a suitably distance from ammable or combustible material using
suitable insulation or an air space.
It is FORBIDDEN to pass system piping or air ducts inside the ue. It is also forbidden to create moveable or xed openings on
the ue itself, for the connection of further dierent appliances (See chapter CONNECTING A FIREPLACE OR OPEN HEARTH TO THE
FLUE).
27
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica Termoisotta DSA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica Termoisotta DSA in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 8,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of La Nordica Termoisotta DSA

La Nordica Termoisotta DSA User Manual - Dutch - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info