696253
31
Zoom out
Zoom in
Previous page
1/88
Next page
ENGLISH
CALCULATION OF THE THERMAL POWER
There is not an absolute rule for calculating the correct necessary power. This power is given according to the space to be heated, but it
depends also largely on the insulation. On an average, the caloric value necessary for a properly insulated room is 30 kcal/h per m
3
(for an
external temperature of 0°C).
Given that 1 kW corresponds to 860 kcal/h, it is possible to adopt a value of 35 W/m
3
.
Let’s suppose one wishes to heat a room of 150 m
3
(10 x 6 x 2.5 m) in an insulated apartment. In this case, it is necessary to have 150 m
3
x 35
W/m
3
= 5250 W or 5,25 kW. As main heating, a 8 kW device is therefore sucient.
Approximate combustion value Required quantity in relation to
1 kg of dry wood
Fuel Unit kcal/h kW
Dry wood (15% humidity)
kg 3600 4.2 1,00
Wet wood (50% humidity) kg 1850 2.2 1,95
Wood briquettes kg 4000 5.0 0,84
Brown coal briquettes kg 4800 5.6 0,75
Normal anthracite kg 7700 8.9 0,47
Coke kg 6780 7.9 0,53
Natural gas m
3
7800 9.1 0,46
Naphtha L 8500 9.9 0,42
Electricity kW/h 860 1.0 4,19
ROUTINE MAINTENANCE PERFORMED BY QUALIFIED TECHNICIANS
Routine maintenance must be performed at least once a year.
Using wood as solid fuel, the generator requires annual routine maintenance, which must be performed by a qualied technician, using
only original spare parts.
Failure to comply can jeopardise the safety of the appliance and make the warranty null and void.
Respecting the frequencies of cleaning reserved for the user described in the use and maintenance manual, the generator is guaranteed
correct combustion over time, preventing any anomalies and/or malfunctioning that could require more interventions of the technician.
Requests for routine maintenance are not contemplated in the product warranty.
GASKETS
The gaskets guarantee the tightness of the stove and its consequent good functioning.
They must be controlled periodically. They must be replaced immediately if they are worn or damaged.
These operations must be carried out by a qualied technician.
CONNECTION TO THE FLUE
Vacuum and clean the pipe that leads to the ue yearly or any time that it is necessary. If there are horizontal tracts, the residue must be
removed before it can prevent the passage of the fumes.
CLEANING OF THE COLLECTION CASING COOKING THROUGH THE OVEN
The smokes collection casing can be cleaned either through the oven (remove the horizontal sheet metal which is the base of the oven See
Picture 10) the cooker or from the top.
To this purpose remove the circles of the cooking plate and disassemble the smokes pipe from the exhaust small trunk. Cleaning can be made
with a brush and a vacuum cleaner.
IMPORTANT: please verify that the deectors are set as indicated in the Picture.
Pay ATTENTION that after cleaning all dismounted parts are reinstalled hermetically.
31
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for La Nordica Rosetta Sinistra BII at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of La Nordica Rosetta Sinistra BII in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 8,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of La Nordica Rosetta Sinistra BII

La Nordica Rosetta Sinistra BII User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info